Electrical Characteristics of Piezoelectric Transformer for Driving A 28W Fluorescent Lamp

28W(T5) 형광등 구동용 압전트랜스포머의 전기적 특성

  • 류주현 (세명대학교 전기공학과) ;
  • 황상모 (세명대학교 전기공학과) ;
  • 윤광희 (세명대학교 전기공학과) ;
  • 김종선 (삼성전기 재료연구센타 세라믹팀) ;
  • 박창엽 (세명대학교 전기공학과)
  • Published : 2000.07.01

Abstract

In this study, contour-vibration-mode Pb($Ni_{1/2}$,$W_{1/2}$)$O_3$-Pb(Zr,Ti)$O_3$ piezoelectric transformers for driving a 28W(T5) fluorescent lamp were fabricated to the modified filter structure with ring and dot electrodes which has been developed for application in 455kHz AM radios. The piezoelectric transformers were fabricated to the size of $31.5$\times$31.5$\times$2.5$mm^3$ with the variations of ring/dot electrode area ratio. Driving of piezoelectric transformer was carried out with input region for the ring electrode and output region for the dot electrode. The electrical properties and characteristic temperature rises caused by the vibration were measured at various load resistances. A 28 W fluorescent lamp, T5, was successfully driven by the fabricated transformer. The transformer with ring/dot electrode area ratio of 1.83 exhibited the best properties in terms of output power, efficiency and characteristic temperature rise, 30.95 W, 97.57% and8.3$^{\circ}C$ respectively.

Keywords