• Title/Summary/Keyword: Lamp load

Search Result 92, Processing Time 0.032 seconds

A Study on Series Inverter for a Fluorescent Lamp Load (형광등용직렬 인버터에 관한 연구)

  • Park, Min-Ho;Hong, Soon-Chan;Oh, Young-Chul
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.1
    • /
    • pp.7-12
    • /
    • 1983
  • When emergency lighting using a D.C. source is needed, we select the fluorescent lamp that has higher efficiency than that of an incandescene lamp. This paper deals with a series inverter for a fluorescent lamp load, which has high frequency output characteristics. First, the appropriate operating frequency is determined and second, the optimum value of circuit elements is determined in consideration of several important conditions. The results obtained by experimentations are represented.

  • PDF

Stability of hair-tail angling fishing boat according to the induction fishing lamp installation (인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능)

  • Seongjae JEONG;Seongwook PARK;Myongkok JEONG;Geumcheol JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

A Study on Heat Flux Characteristics of Tubular Quartz Lamp for Thermal Load Design of High Temperature Structural Test (석영 가열램프의 열 유속 특성 파악을 통한 고온 구조시험의 열 하중 설계에 관한 연구)

  • Kim, Junhyeok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.355-363
    • /
    • 2022
  • Development of supersonic flying vehicle is one of the most latest issue in modern military technology. Specifically, structural integrity of supersonic flying vehicle can be verified by high temperature structural test. High temperature structural test is required to consider thermal load caused by aerodynamic heating while applying structural load simultaneously. Tubular quartz lamps are generally used to generate thermal load by emitting infrared radiation. In this study, modified heat flux model of tubular quartz lamp is proposed based on existing model. Parameters of the proposed model are optimized upon measured heat flux in three dimensions. Finally, thermal load of plate specimen is designed by the heat flux model. In conclusion, it is possible to predict heat flux applied on plate specimen and desired thermal load of high temperature structural test can be obtained.

Novel Dummy Load for 40W Fluorescent Lamps

  • Choi, Bo-Hwan;Kim, Hyun-Jae;Yeo, In-Yong;Kim, Bong-Cheol;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.731-738
    • /
    • 2012
  • A new fluorescent dummy load to replace one of the fluorescent lamps in a dual lamp type rapid-start ballast for halving the lamp power is proposed. Using a circuit composed of a fundamental compensation circuit and a harmonic filter circuit, a new fluorescent dummy load having superior characteristics than a conventional dummy load is developed. The design principle and architecture of the proposed fluorescent dummy load is explained and verified by experiments.

Thermal Characteristics of Electric Wiring for Halogen Warm Lamp Group and Automatic Waterer Group at Stable (우사(牛舍)에서의 할로겐보온등군(群) 및 자동급수통군에 대한 전기배선의 열적 특성)

  • Kim, Doo-Hyun;Yoo, Sang-Ok;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.48-53
    • /
    • 2014
  • This study is analyzed for electrical fire danger by electric equipments through surveys of stable owners and the field investigation at 64 stable. Also, an experiment is performed to analyze the thermal characteristics of 4 types electric wiring according to the number of operating halogen warm lamp group and automatic waterer group in Beon-young stable in the Cheongwon location. The survey is done to investigate the occurrence of electrical fire, electric equipment, causes and dangerous equipment. As a result, halogen warm lamp group and automatic waterer group are found to have dangerous loads. In the field investigation, the mode of load capacity of the halogen warm lamp group and automatic waterer group was investigated. The mode of load capacity of halogen warm lamp group (over 3 years) is found 17A and that of the auto waterer group (10 years) is 16A. In this experiment, the halogen warm lamp group aged at least 3 years showed $109^{\circ}C$ while that aged less than 1 year appeared $83^{\circ}C$, showing the max gap of $26^{\circ}C$. The automatic waterer group aged 10 years showed $90^{\circ}C$ while that aged less than 1 year appeared $68^{\circ}C$, showing the max gap of $22^{\circ}C$. These findings indicate that the mode of load capacity needs to be considered in selecting and installing wiring for the electric equipment construction of halogen warm lamp group and automatic waterer group in stable.

Modeling and Simulation of an Electrodeless lamp system (무전극등 시스템의 모델 및 시뮬레이션 연구)

  • 한수빈;박석인;정봉만;정학근;김규덕;유승원
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.237-239
    • /
    • 2003
  • Characteristics of electrodeless lamp as a load of the ballast is different compared to normal fluorescent lamp because the lamp includes the magnetics for inductive discharging process. So somewhat different modeling is necessary to make a proper power match between the lamp and ballast. Modeling of an electrodeless lamps, Endura of Osram, is presented in this paper. Simulation with a result of experiment is given for a verification of proposed model.

  • PDF

Modeling and Analysis of Power Piezoelectric Transformer and Its Application to Fluorescent Lamp Ballasts (압전 변압기의 모델링과 형광등 안정기회로에의 응용)

  • Choe, Seong-Jin;Lee, Gyu-Chan;Jo, Bo-Hyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.376-383
    • /
    • 1999
  • The piezoelectric transformer (PT) is an electro-mechanical device that transfers electrical energy through a mechanical vibration. In this paper, a PT operating in the contour vibration mode is introduced for an application of fluorescent lamp ballast. Utilizing its inherent characteristics of the LC resonator and a high voltage gain to ignite the lamp in light load condition, an investigation of a power piezoelectric transformer as a potential component for a fluorescent lamp ballast is discussed. PT is easy to be produced in mass and reduces the cost of the ballast. The modified equivalent circuit model of the PT considering the operating current level is derived to design the fluorescent lamp ballast. This model describes the voltage gain of the PT in wide load variations and various input current levels. The experimental and simulation results are provided to verify theoretical analysis. The power capacity of the currently developed PT is relatively low (15W), but it can be increased by adopting a multi-layer structure and is currently under investigation. It is also possible to parallel the PT for higher power processing.

  • PDF

A Stuty of Protection Circuit for Discharge Lamp Ballast (방전등 안정기의 보호회로 기술 현황)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jung, Bong-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.133-135
    • /
    • 2008
  • In a design of ballast for discharge lamp, various kind of protection circuit are essential for safe operation. In this paper, overvoltage and current detection, no-load detection, lamp-fault detection, end of lamp detection for protection are introduced. Individual circuit operation and their function are described with the base that all circuit form is similar with overvoltage protection circuit.

  • PDF

A Dynamic Characteristics on Non-linear Voltage Electric Equipment under Voltage Sag (순간전압강하에 대한 비선형 저압전기기기의 동적특성)

  • Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.336-343
    • /
    • 2008
  • In this study, a transition of power quality was characterized by non-linear voltage electric equipments under voltage sag. The test was inputted voltage sag to IPC(Sag Generator) from AVR, and then to equipments by IPC which adjust voltage magnitude and duration. The load test which non-linear voltage electric equipments used PLC, Magnetic Contactor, SMPS, HID Lamp. The test result was different from each other according to a manufacturing companys, models, and equipments. PLC was greatly described to be stabilized voltage sag in case of no load then rated load. Magnetic Contactor was made a difference to phase angles on voltage sag, which was $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. HPD Lamp was described to be stabilized the sodium lamp, and to be unstabilized the metal hailed lamp. The test result was showed CBEMA curve that stand for evaluated responsiveness of voltage sag. This study was tested description to dynamic characteristics on non-linear voltage electric equipment under voltage sag. There was hoped that power system designed the essential particulars.

The Performance of generated Heating Energy from Interior Lighting Fixtures (실내조명의 발열량 예측에 관한 실험 연구)

  • Choi, Jong-seon;Lim, Hong-Soo;Kim, Kyung-Ah;Lee, Keum-hwan;Koo, Jae-Oh;Kim, Gon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.