• 제목/요약/키워드: Laminating

검색결과 179건 처리시간 0.024초

가압주조방식인 IPS Empress로 세라믹 주조체를 제작 후 적층 형 성한 라미네이트 제작 증례 (Laminate production by manufacturing ceramic casting body and laminating using IPS Empress: a pressure casting method)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.81-86
    • /
    • 2023
  • Purpose: This study aimed to observe the effect of laminate veneer on patient's teeth based on the manufacturing of laminate veneer restorations, which are produced by fabricating a ceramic cast body using IPS Empress, a pressure casting method and then forming the veneer by layering. Subsequently, we assessed the potential of its clinical application. Methods: This study discusses and preserves various treatment plans, such as diagnostic wax-up and treatment room diagnosis, for patients who visit the hospital to improve the appearance of teeth due to diastema of maxillary teeth, inexperienced resin filling, lack of esthetics, and external teeth. A ceramic cast body is constructed using IPS Empress, which is an effective and aesthetic restoration pressure casting method to restore the veneer with a laminate made by layering. Results: Compared with the preoperative state, the frontal view of the patient after the final restoration showed the formation of a natural smile line; the space between the central and lateral incisors was filled in synchronously with the adjacent teeth. In addition, the emergence profile is maintained by reducing the over-contour as much as possible. Conclusion: The patient's quality of life is improved by providing them with a satisfactory natural smile.

Measurement of Dynamic MOE of 3-Ply Laminated Woods by Flexural Vibration and Comparison with Blending Strength and Creep Performances

  • Park, Han-Min;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권2호
    • /
    • pp.46-57
    • /
    • 2006
  • To estimate nondestructively strength performances of laminated woods, 3-ply parallel- and cross-laminated wood specimens exposed under atmosphere conditions after bending creep test were prepared for this study. The effects of density of species, arrangement of laminae and lamination types on dynamic MOE obtained by flexural vibration were investigated, and regression analyses were conducted in order to estimate static bending strength and bending creep performances. Dynamic MOE of parallel-laminated woods showed 1.0~1.2 times higher values than static bending MOE, and those of cross-laminated woods showed 1.0~1.4 times higher values than static bending MOE. The degree of anisotropy of dynamic MOE perpendicular to the grain of face laminae versus that parallel to the grain of face laminae was markedly decreased by cross-laminating. There were strong correlations between dynamic MOE by flexural vibration and static bending MOE (correlation coefficient r = 0.919~0.972) or bending MOR (correlation coefficient r = 0.811~0.947) of 3-ply laminated woods, and the correlation coefficient were higher in parallel-laminated woods than in cross-laminated woods. It indicated that static bending strength performances were able to be estimated from dynamic MOE by flexural vibration. Also, close correlations between the reciprocal of dynamic MOE by flexural vibration and initial compliance at 0.008 h of 3-ply laminated woods were found (correlation coefficient r = 0.873~0.991). However, the correlation coefficient between the reciprocal of dynamic MOE and creep compliance at 168 h of 3-ply laminated woods was considerably lower than those between dynamic MOE and initial compliance, and it was hard to estimate creep compliance with a high accuracy from dynamic MOE due to the variation of creep deformation.

Performance Analysis Based on Bonded Surface Designs for Stitchless Welded Products

  • Kim, Keum-Wha;Choi, Hei-Sun
    • 한국의류학회지
    • /
    • 제36권6호
    • /
    • pp.583-591
    • /
    • 2012
  • This study selected three model designs used for air injection type welding clothes designed for insulation purposes and analyzed the performance of each design. The bending characteristics were analyzed in order to identify the flexibility of the welded areas; subsequently, the seam breaking strength and water pressure resistance were analyzed to identify the bonding strength. In addition, two types of waterproof fabric, polyurethane (PU) coated 2 layer and PU laminated 2 layer fabrics, were used for a performance analysis, according to fabric processing specifications. The circle type showed the highest flexibility in the terms of bending characteristics that influence wearability and were followed by the wave and the straight type. In terms of breaking strength, the straight type showed the highest breaking strength, followed by the wave and the circle type. The water pressure resistance analysis found that the wave type was superior to the straight type in terms of water pressure resistance. The wave type is deemed to be a design type suitable for maximizing performance, provided that the issue of stabilization in the welding production process is addressed. Looking at the bending characteristics of waterproof fabric for each specification, the laminating waterproof cloth outperformed the coated waterproof cloth in terms of flexibility. However, in terms of seam breaking strength, the coated waterproof cloth outperformed the laminated cloth. In contrast, the water pressure resistance of the laminated waterproof fabric was found to be higher than the coated waterproof fabric, leading to the conclusion that the bonding strength of the laminated waterproof fabric is higher than that of the coated waterproof fabric based on the assumption of injecting air.

마그네슘 합금 AZ31의 온간성형과 재료특성변화에 관한 연구 (Variation of Material Characteristics of a Hot-formed AZ31 Magnesium Alloy)

  • 서창민;허광호;김효민;서민수
    • 대한기계학회논문집A
    • /
    • 제37권7호
    • /
    • pp.913-919
    • /
    • 2013
  • 본 연구에서는 마그네슘 합금 AZ31을 적용한 배터리 팩 케이스를 개발하여 자체 진동 및 외부 충격으로부터 배터리를 보호하도록 하며, 기존 스틸 소재 대비 50% 이상 경량화하여 친환경 기술개발을 목적으로 한다. 또한, 제품의 복잡한 형상 및 마그네슘 소재의 특성으로 제품을 성형하기에는 힘든 측면이 많으므로 이를 해결하기 위해 마그네슘 합금소재의 온도별 최적성형조건을 제시하고자 한다. 즉 AZ31의 성형방법에 따라 상온, $230^{\circ}C$, $250^{\circ}C$$270^{\circ}C$의 4가지 조건하의 시험편으로 인장시험, 경도시험, 부식시험 및 피로시험 등을 실시하여 기계적 특성을 정량적으로 분석하였고, 또 FEM해석을 통하여 자동차 부품 배터리 팩 케이스 개발에 적용토록 하였다.

환경 모니터링을 위한 압력 센서 연구 (A Study of Pressure Sensor for Environmental Monitoring)

  • 황현석;최원석
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.225-229
    • /
    • 2011
  • 본 연구에서는 환경 모니터링을 위한 정전용량형 압력센서를 저온동시소성세라믹 (LTCC) 기술을 이용하여 제작하였다. LTCC 기술은 실리콘 기반의 기술에 비하여 낮은 생산 단가, 높은 수율, 3차원 구조물의 용이한 제작성 등으로 인하여 센서 응용분야에서 중요한 역할을 담당하고 있으며, 특히 열악한 외부환경에 적합한 물질이다. 400 ${\mu}m$ 두께 삼차원 구조의 LTCC 다이어프램은 NEG사의 MLS 22C 상용 파우더를 이용하여 100 ${\mu}m$ 두께의 그린쉬트를 적층하고 동시소결하여 제작하였다. 제작한 다이어프램은 공동의 면적에 따른 센싱특성을 평가하기 위하여 각각 25, 49 $mm^2$의 두 종류를 제작하였다. 정전용량형 압력센서를 구현하기 위하여 상부에는 열증착기를 이용하여 Au 금속박막을 증착하였고 하부에는 상용 알루미늄막을 압착하였다. 압력에 따른 센싱특성을 평가하기 위하여 제작된 측정시스템을 이용하여 0~30 psi의 압력을 가변하여 압력센서의 정전용량 변화를 측정한 결과 두 센서 모두에서 선형적인 센싱 특성을 나타냄을 확인하였다.

Healing of Aneurysm after Treatment Using Flow Diverter Stent : Histopathological Study in Experimental Canine Carotid Side Wall Aneurysm

  • Lee, Jong Young;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권1호
    • /
    • pp.34-44
    • /
    • 2020
  • Objective : Despite widespread use of flow diverters (FDs) to treat aneurysms, the exact healing mechanism associated with FDs remains poorly understood. We aim to describe the healing process of aneurysms treated using FDs by demonstrating the histopathologic progression in a canine aneurysm model. Methods : Twenty-one side wall aneurysms were created in common carotid artery of eight dogs and treated with two different FDs. Angiographic follow-ups were done immediately after placement of the device, 4 weeks and 12 weeks. At last follow-up, the aneurysm and the device-implanted parent artery were harvested. Results : Histopathologic findings of aneurysms at 4 weeks follow-up showed intra-aneurysm thrombus formation in laminating fashion, and neointimal thickening at the mid-segment of aneurysm. However, there are inhomogenous findings in aneurysms treated with the same type of FD showing same angiographic outcomes. At 12 weeks, aneurysms of complete and near-complete occlusion revealed markedly shrunken aneurysm filled with organized connective tissues with thin neointima. Aneurysms of incomplete occlusion at 12 weeks showed small amount of organized thrombus around fringe neck and large empty space with thick neointmal formation. Neointimal thickness and diameter stenosis was not significantly different between the groups of FD specification and follow-up period. Conclusion : Intra-aneurysmal thrombus formation and organization seem to be an important factor for the complete occlusion of aneurysms treated using the FD. Neointimal formation could occur along the struts of the FD independently of intra-aneurysmal thrombus formation. However, neointimal formation could not solely lead to complete aneurysm healing.

CFRP 복합재료 직교 격자 구조의 기계적 특성 연구 (Study on Mechanical Properties of CFRP Composite Orthogonal Grid Structure)

  • 백상민;임성준;김민성;고명균;박찬익
    • Composites Research
    • /
    • 제31권2호
    • /
    • pp.69-75
    • /
    • 2018
  • 본 연구에서는 직물 탄소섬유강화플라스틱 복합재를 직교 격자 형상으로 적층한 패널 구조를 제안하고, 기계적 특성에 대한 분석 및 연구를 수행하였다. 프리프레그를 재단하여 적층하는 방식으로 직교 격자 구조를 제작하였으며, 하부의 적층판과 오토클레이브 공정 일체 성형을 통해 격자 패널 구조를 제작하였다. 본 연구에서는 인장, 압축, 전단, 굽힘 하중을 부가하여 제안된 격자 패널 구조의 거동을 확인하였으며, 이러한 시험을 통해 본 직교 격자 구조물의 강성 증가 효과를 입증하였다. 또한, 유한요소해석 모델을 구축하여 시험 결과와 비교하였으며, 이를 통해 시험과 해석의 타당성을 확인하였다.

고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구 (A Study on Improvement of the low temperature flex resistance test method about high waterproof materials)

  • 이민희;문선정;고혜지;홍성돈
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

Microwave Dielectric Properties of Ti-Te system Ceramics for Triplexer Filter

  • Choi, Eui-Sun;Lee, Moon-Woo;Lee, Sang-Hyun;Kang, Gu-Hong;Kang, Gap-Sul;Lee, Young-Hie
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.263-269
    • /
    • 2011
  • In this study, the compositions for the microwave dielectric materials were investigated to obtain the improved dielectric properties, the high temperature stability, and the sintering temperature of less than $900^{\circ}C$, which was necessary for cofiring with the internal conductor of silver. In addition, the dielectric sheets were prepared by the tape casting technique, after which the sheets were laminated and sintered. In this process, the optimum ratio of powder and binder, laminating pressure, temperature, and possibility for cofiring with the internal conductor were studied. Finally, multilayer chip treplexer filter for the 800-2,000 MHz range were fabricated, and the frequency characteristics of the triplexer filter were investigated. When the $0.6TiTe_3O_8-0.4MgTiO_3+3wt%SnO+7wt%H_3BO_3$ ceramics were sintered at $820^{\circ}C$ for 0.3 hours, the microwave dielectric properties of the dielectric constant of 29.91, quality factor of 33,000 GHz, and temperature coefficient of resonant frequency of -2.76 ppm/$^{\circ}C$ were obtained. Using the Advanced Design System (ADS) and High Frequency Structure Simulator (HFSS), the multilayer chip triplexer filter acting at the range of 800-2,000 MHz were simulated and manufactured. The manufactured triplexer filter had the excellent frequency properties in the CDAM800, GPS and PCS frequency regions, respectively.

응집반응 검출을 위한 미세 유체 Lab on a chip의 사출성형 금형 인서트의 디자인 및 제작 (Design and Fabrication of Mold Insert for Injection Molding of Microfluidic tab-on-a-chip for Detection of Agglutination)

  • 최성환;김동성;권태헌
    • 소성∙가공
    • /
    • 제15권9호
    • /
    • pp.667-672
    • /
    • 2006
  • Agglutination is one of the most commonly employed reactions in clinical diagnosis. In this paper, we have designed and fabricated nickel mold insert for injection molding of a microfluidic lab-on-a-chip for the purpose of the efficient detection of agglutination. In the presented microfluidic lab-on-a-chip, two inlets for sample blood and reagent, flow guiding microchannels, improved serpentine laminating micromixer(ISLM) and reaction microwells are fully integrated. The ISLM, recently developed by our group, can highly improve mixing of the sample blood and reagent in the microchannel, thereby enhancing reaction of agglutinogens and agglutinins. The reaction microwell was designed to contain large volume of about $25{\mu}l$ of the mixture of sample blood and reagent. The result of agglutination in the reaction microwell could be determined by means of the level of the light transmission. To achieve the cost-effectiveness, the microfluidic lab-on-a-chip was realized by the injection molding of COC(cyclic olefin copolymer) and thermal bonding of two injection molded COC substrates. To define microfeatures in the microfluidic lab-on-a-chip precisely, the nickel mold inserts of lab-on-a-chip for the injection molding were fabricated by combining the UV photolithography with a negative photoresist SU-8 and the nickel electroplating process. The microfluidic lab-on-a-chip developed in this study could be applied to various clinical diagnosis based on agglutination.