• 제목/요약/키워드: Laboratory set-up

검색결과 240건 처리시간 0.026초

Speeding up the KLT Tracker for Real-time Image Georeferencing using GPS/INS Data

  • Tanathong, Supannee;Lee, Im-Pyeong
    • 대한원격탐사학회지
    • /
    • 제26권6호
    • /
    • pp.629-644
    • /
    • 2010
  • A real-time image georeferencing system requires all inputs to be determined in real-time. The intrinsic camera parameters can be identified in advance from a camera calibration process while other control information can be derived instantaneously from real-time GPS/INS data. The bottleneck process is tie point acquisition since manual operations will be definitely obstacles for real-time system while the existing extraction methods are not fast enough. In this paper, we present a fast-and-automated image matching technique based on the KLT tracker to obtain a set of tie-points in real-time. The proposed work accelerates the KLT tracker by supplying the initial guessed tie-points computed using the GPS/INS data. Originally, the KLT only works effectively when the displacement between tie-points is small. To drive an automated solution, this paper suggests an appropriate number of depth levels for multi-resolution tracking under large displacement using the knowledge of uncertainties the GPS/INS data measurements. The experimental results show that our suggested depth levels is promising and the proposed work can obtain tie-points faster than the ordinary KLT by 13% with no less accuracy. This promising result suggests that our proposed algorithm can be effectively integrated into the real-time image georeferencing for further developing a real-time surveillance application.

Implementation and benchmarking of the local weight window generation function for OpenMC

  • Hu, Yuan;Yan, Sha;Qiu, Yuefeng
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3803-3810
    • /
    • 2022
  • OpenMC is a community-driven open-source Monte Carlo neutron and photon transport simulation code. The Weight Window Mesh (WWM) function and an automatic Global Variance Reduction (GVR) method was recently developed and implemented in a developmental branch of OpenMC. This WWM function and GVR method broaden OpenMC's usage in general purposes deep penetration shielding calculations. However, the Local Variance Reduction (LVR) method, which suits the source-detector problem, is still missing in OpenMC. In this work, the Weight Window Generator (WWG) function has been developed and benchmarked for the same branch. This WWG function allows OpenMC to generate the WWM for the source-detector problem on its own. Single-material cases with varying shielding and sources were used to benchmark the WWG function and investigate how to set up the particle histories utilized in WWG-run and WWM-run. Results show that there is a maximum improvement of WWM generated by WWG. Based on the above results, instructions on determining the particle histories utilized in WWG-run and WWM-run for optimal computation efficiency are given and tested with a few multi-material cases. These benchmarks demonstrate the ability of the OpenMC WWG function and the above instructions for the source-detector problem. This developmental branch will be released and merged into the main distribution in the future.

Comparative analysis of turbulence models in hydraulic jumps

  • Lobosco, Raquel J.;da Fonseca, David O.;Jannuzzia, Graziella M.F.;Costa, Necesio G.
    • Coupled systems mechanics
    • /
    • 제8권4호
    • /
    • pp.339-350
    • /
    • 2019
  • A numerical simulation of the incompressible multiphase hydraulic jump flow was performed to compare the interface prediction through the use of the three RANS turbulence models: $k-{\varepsilon}$, $RNGk-{\varepsilon}$ and SST $k-{\omega}$. A three dimensional no submerged hydraulic jump and a two dimensional submerged hydraulic jump were modeled. Both the geometry and the mesh were created using the open source Gmsh code. The project's geometry consists of a rectangular channel with length and height differences between the two dimensional and three dimensional simulations. Uniform hexahedral cells were used for the mesh. Three refining meshes were constructed to allow to verify simulation convergence. The Volume of Fluid (abbr. VOF) method was used for treatment of the air-water surface. The turbulence models were evaluated in three distinct set up configurations to provide a greater accuracy in the flow representation. In the two-dimensional analysis of a submerged hydraulic jump simulation, the turbulence model RNG RNG $k-{\varepsilon}$ provided a better interface adjust with the experimental results than the model $k-{\varepsilon}$ and SST $k-{\omega}$. In the three-dimensional simulation of a no-submerged hydraulic jump the k-# showed better results than the SST $k-{\omega}$ and RNG $k-{\varepsilon}$ capturing the height and length of the ledge with a better fit with the experimental results.

High-level Expression and Characterization of the Human Interleukin-10 in the Milk of Transgenic Mice

  • Zneng, Z. Y.;B. H. Sohn;K. B. Oh;W. J. Shin;Y. M. Han;Lee, K. K.
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2003년도 학술발표대회 발표논문초록집
    • /
    • pp.46-46
    • /
    • 2003
  • Interleukin-10 (IL-10) is a homodimeric protein with a wide spectrum of anti-inflammatory and immune activities. It inhibits cytokine production and expression of immune surface molecules in various cell types. The transgenic mice carrying the human IL-10 gene in conjunction with the bovine $\beta$-casein promoter produced the human IL-10 in milk during lactation. Transgenic mice were generated using a standard method as described previously. To screen transgenic mice, PCR was carried out using chromosomal DNA extracted from tail or toe tissues with a primer set. In this study, stability of germ line transmission and expression of IL-10 gene integrated into host chromosome were monitored up to generation F15 of a transgenic line. When female mouse of generation F9 was crossbred with normal male, generation F9 to F15 mice showed similar transmission rates (66.0$\pm$20.13%, 61.5$\pm$16.66%, 41.1$\pm$8.40%, 40.7$\pm$20.34%, 61.3$\pm$10.75%, 49.2$\pm$18.82%, and 43.8$\pm$25.91%, respectively), implying that the IL-10 gene can be transmitted stably up to long term generation in the transgenic mice. For ELISA analysis, IL-10 expression levels were determined with an hIL-10 ELISA and a mIL-10 ELISA kit in accordance with the supplier's protocol. Expression levels of human IL-10 from milk of generation F9 to F13 mice were 3.6$\pm$1.20 mg/ml, 4.2$\pm$0.93 mg/ml, 5.7$\pm$1.46 mg/ml, 6.3$\pm$3.46 mg/ml, and 6.8$\pm$4.52 mg/ml, respectively. These expression levels are higher than in generation F1 (1.6 mg/ml) mice. We concluded that transgenic mice faithfully passed the transgene on their progeny and successively secreted target proteins into their milk through several generations, although there was a little fluctuation in the transmission frequency and expression level between the generations.

  • PDF

Estimation of Nitrite Concentration in the Biological Nitritation Process Using Enzymatic Inhibition Kinetics

  • GIL, KYUNG-IK;EUI-SO CHOI
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권3호
    • /
    • pp.377-381
    • /
    • 2002
  • Recently, interests to remove nitrogen in the nitritation process have increased because of its economical advantages, since it could be a short-cut process to save both oxygen for nitrification and carbon for denitrification compared to a typical nitrification. However, the kinetics related with the nitritation process has not yet been fully understood. Furthermore, many useful models which have been successfully used for wastewater treatment processes cannot be used to estimate effluent nitrite concentration for evaluating performance of the nitritation process, since the process rate equations and population of microorganisms for nitrogen removal in these models have been set up only for the condition of full nitrification. Therefore, the present study was conducted to estimate an effluent nitrite concentration in the nitritation process with a concept of enzymatic inhibition kinetics based on long-term laboratory experiments. Using a nonlinear least squares regression method, kinetic parameters were accurately determined. By setting up a process rate equation along with a mass balance equation of the nitrite-oxidizing step, an effluent nitrite concentration in the nitritation process was then successfully estimated.

악하부종괴에 대한 임상적 연구 (CLINICAL STUDY ON SUBMANDIBULAR MASSES)

  • 장현석;유준영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권4호
    • /
    • pp.701-705
    • /
    • 1996
  • There are many kind of diagnostic entities in submandibular or neck masses, and we can set up treatment plan and estimate treatment result, prognosis by accurate diagnosis. By reasoning medical and dental history, physical examination, anatomical consideration of masses in submandibular or neck area, location of masses, laboratory and radiographic studies, we can formulate a clinical diagnosis or differential diagnosis. Although a clinical diagnosis might suffice in some instances, a definitive(microscopic) diagnosis is frequently required for proper treatment. In order to get some information about making accurate diagnosis and setting up appropriate treatment plan, we did clinical study and histopathologic classification of 82 patients who visited and were operated for submandibular masses at Department of Oral and Maxillofacial Surgery in Seoul National University Hospital from 1988 to 1992. The result were as follows : 1. Submandibular masses occured most frequently in forties and fifties, and there was no sex predilection. 2. Chief complaints were in order of mass, swelling, pain and consistency were soft mass, mobile hard mass, firm mass, diffuse swelling in descending order. 3. Most frequent pathologic finding was lymphadenitis. 4. Site of submandibular masses were submandible, neck, submental, retromandible in descending order, and there was no predilection between left and right side. 5. Accuracy rate between clinical impression and result was 51.2%.

  • PDF

내환경성 금속인식 정보단말기에 관한 연구 (Data Terminal for Metal Detection Application in Hazardous Environment)

  • 최규남
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1183-1188
    • /
    • 2011
  • 고온다습하며 이물질이 존재하는 일반적인 금속감지 기술이 적용되기 어려운 환경에서도 사용할 수 있는 금속위치감지 방법을 제안한다. 섭씨 300도가 넘는 환경에서는 마이크로웨이브, 초음파, 광파를 매체로 하는 일반적인 송수신용 전자소자를 사용하는 금속감지 센서는 전자소자의 동작온도 범위를 넘어서므로 적용하는데 어려움이 있었다. 본 연구에서는 금속감지를 위하여 노출되는 면에는 수동소자를 사용하고 전자파를 금속 위치감지에 이용하는 기법을 사용한 금속의 위치감지 장치에서 전자파의 주파수, 감지거리가 금속감지 센서의 감도에 미치는 영향을 측정하였다. 측정된 결과는 500mm 간격에서도 1mm 해상도를 갖고 위치를 감지할 수 있으며 고온에서도 금속의 위치 측정이 가능함을 보여주었다.

Experimental and numerical studies on the cyclic behavior of R/C hollow bridge piers with corroded rebars

  • Cardone, D.;Perrone, G.;Sofia, S.
    • Earthquakes and Structures
    • /
    • 제4권1호
    • /
    • pp.41-62
    • /
    • 2013
  • A comprehensive experimental program of cyclic tests on 1:3-scale models of bridge piers is going to be carried out at the Laboratory of Structures and Materials of the University of Basilicata. The testing models include eight RC single shaft piers with hollow circular cross section. Four piers have been realised using corroded steel rebars. In this paper, the results of preliminary numerical simulation analyses of the cyclic behaviour of the piers, carried out with Opensees using fiber-based models, are presented. Pull-out and lap-splice effects of steel rebars have been taken into account in the numerical analyses. First, the experimental specimens and the test set up are presented. Next, the results of the numerical analyses are discussed. In the numerical analyses, different configurations and levels of corrosion have been considered. The effective stiffness and equivalent damping of the piers is reported as a function of pier ductility and pier drift.

BLACK HOLE-IGM FEEDBACK, AND LINKS TO IGM FIELDS AND CR'S

  • KRONBER PHILIPP P.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.501-507
    • /
    • 2004
  • The uniquely large dimensions of Giant radio galaxies (GRGs) make it possible to probe for stringent limits on total energy content, Faraday rotation, Alfven speeds, particle transport and radiation loss times. All of these quantities are more stringently limited or specified for GRG's than in more 'normal' FRII radio sources. I discuss how both global and detailed analyses of GRG's lead to constraints on the CR electron acceleration mechanisms in GRG's and by extension in all FRII radio sources. The properties of GRG's appear to rule out large scale Fermi-type shock acceleration. The plasma parameters in these systems set up conditions that are favorable for magnetic reconnection, or some other very efficient process of conversion of magnetic to particle energy. We conclude that whatever mechanism operates in GRG's is probably the primary extragalactic CR acceleration mechanism in the Universe.

Picosecond Absorption Kinetic Spectrometer with a Laser and a Streak Camera

  • Jang, Du-Jeon
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.172-176
    • /
    • 1990
  • A high resolution picosecond absorption kinetic spectrometer utilizing dye emission and a streak camera is presented and compared with other methods of picosecond transient absorption measurements. Typical transient absorption and bleach recovery kinetics measured with this spectrometer are shown. Single wavelength transient absorption or ground state bleach recovery kinetics are determined on the basis of a single laser shot, so that the samples are relatively free frm decomposition by irradiation. Excellent kinetics may be obtained from the near UV to the near IR and are not subject to interference from luminescence of samples. The sensitivity of this spectrometer is very high and it is reasonably easy and convenient to set up and use.

  • PDF