• Title/Summary/Keyword: Laboratory proficiency testing

Search Result 25, Processing Time 0.021 seconds

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field (환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구)

  • PARK, Kyunghwan;LEE, Cheolgyu
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

Proficiency Testing by Inter-Laboratory Comparisons for Braking Lining (제동 라이닝애 대한 시험소간 비교에 의한 숙련도시험)

  • Chung Jong-Duk;Kwon Sung-Tae;Hong Yung-Ki;Kim Won-kyung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.586-591
    • /
    • 2003
  • This paper describes the result of proficiency testing by inter-laboratory comparisons for braking lining. Proficiency testing provides an objective means of assessing and demonstrating the validity and reliability of test results produced by laboratories. To more accuracy comparison test for braking lining test, they will be made the same test procedure and environment conditions.

  • PDF

Interlaboratory Study for Proficiency Testing on the Water Toxicity Determinations by Acute Toxicity Test with Daphnia magna (국내 생태독성 분석기관에 대한 숙련도시험 결과 평가)

  • Kim, Jongmin;Shin, Kisik;Yu, Soonju;Kim, Myeong Ock;Choe, Sung Hun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.632-637
    • /
    • 2014
  • Proficiency testing by interlaboratory comparisons is used to determine the performance of individual laboratories. In order to verify the quality of acute toxicity testing with Daphnia magna, National Institute of Environmental Research in South Korea is regularly organizing interlaboratory comparisons to estimate the analytical accuracy of different laboratories. Total 58 laboratories located in South Korea took part in interlaboratory proficiency testing scheme with three proficiency testing samples. TU(Toxic Unit) values of each laboratory were determined and robust z-score was calculated in order to evaluate the proficiency levels. Based on the robust z-score classification, 74% of the participant laboratories showed a satisfactory performance (43 laboratories). The main reason of 'unsatisfactory' performance seemed to be considered that the unsuitable management of test organism incubation system and the lack of experience on the identification of the test organism condition by effect of toxicity.

A Study on Proficiency Comparison Testing Between Testers Using ISO/IEC 25023 Software Quality Characteristics Evaluation (ISO/IEC 25023 소프트웨어 품질 특성 평가를 이용한 시험자간 비교시험에 관한 연구)

  • Lee, Chang-Hee;Kim, Myung-Sup;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.18-27
    • /
    • 2020
  • This study compared and analyzed the results of proficiency testing between testers based on the international standard ISO/IEC 17043 proficiency testing requirements using ISO/IEC 25023 software quality characteristics evaluation. Application of the test was submitted to the KASTO as a software test in the electric test field defined by KOLAS. Among ISO/IEC 25023, the evaluation items for proficiency testing between testers were selected as functional completeness and time behavior. The comparison test between testers was carried out on May 28, 2019 at the accredited LG Electronics SW Laboratory in Seoul and attended by KOLAS assessors. The test evaluation method was measured once per tester with functional completeness, and measurement was repeated 10 times per tester according to time behavior. As a result, in the case of functional completeness, all 12 test steps were passed, and the satisfaction was evaluated. Time behavior was repeated 10 times, and the mean was 9.45 ± 0.01 seconds for testers 1 and 3 and 9.52 ± 0.0 seconds for tester 2, but there was no statistically significant difference. In conclusion, the proficiency of the testers was equal, and the reliability of the test results of the test institute was confirmed.

An Experimental Study on the Compressive Strength Deviation of Concrete With Different Consolidation Methods (다짐 방법에 따른 콘크리트 압축강도 편차에 관한 실험적 연구)

  • Seo, Il;Jun, Woo-Chul;Park, Hee-Gon;Lee, Hyun-Seok;Lee, Jae-Sam;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.77-78
    • /
    • 2011
  • This paper presents a basic study which is to develop concrete cylinder moulds for a proficiency testing compressive strength of concrete among laboratories accredited Korea Laboratory Accreditation Scheme(KOLAS). The concrete cylinder moulds sufficiently have homogeneity for a proficiency testing which is a means of assessing the ability of laboratories to competently perform specific test and measurements. The concrete compressive strength specimens placed different consolidation methods were analyzed by a statistic technique. The methods of consolidation are rodding, and internal or external vibration.

  • PDF

Establishment of National Quality Control System for Analytical Laboratory of Pesticide Products by Proficiency Testing (농약 이화학시험 분석기관의 숙련도시험을 통한 정도관리체계 확립 연구)

  • Chang, Hee-Ra;Park, Hyo-Kyung;Lim, Youngjoo;Kim, Kwang-Ho;Kim, Chan Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.350-356
    • /
    • 2012
  • Performance of proficiency testing and the validation of analytical method was included a scheme of quality assurance in analytical chemistry laboratory to monitor a laboratory's performance abilities and produce consistently reliable data. This study was assessed the applicability of proficiency testing scheme proposed for analytical laboratories of pesticide product in domestic. The validation of analytical methods, stability and homogeneity for formulated pesticide products (emulsifiable concentrate) of emamectin benzoate and lufenuron was confirmed for the proficiency testing. The z-score of 33 participation laboratories for emamectin benzoate were that the numbers of outlier were 2 laboratories (6.0%), z-score outside the range from -3 to 3 designated "unaccptable" were 2 laboratories and z-score in the ranges -2 to -3 and 2 to 3 designated "questionable" were 3 laboratories (9.0%). Three laboratories (9.0%) showed the z-score designated "questionable" for lufenuron. The additional proficiency testing for various product types will be needed to establish the scheme of quality control.

Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories (KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험)

  • Chun, Sejong;Yoon, Byung-Ro;Kim, Soo-Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • KOLAS (KOrea Laboratory Accreditation Scheme) belongs to APLAC (Asia Pacific Laboratory Accreditation Cooperation). KOLAS manages the accreditation scheme for measurement traceability to SI units. As per June 2016, there are 22 KOLAS laboratories for liquid flow metering. Among them, 12 laboratories participated in the proficiency test (PM2015-08) for water flow metering, organized by KASTO (Korea Association of Standards and Testing Organizations). This proficiency test was performed with three kinds of flow ranges ($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m^3/h{\sim}200m^3/h$) considering the CMC (calibration and measurement capability) of the participating laboratories. The purpose of the proficiency test was to find out measurement equivalence of the CMC's between each participating laboratory and the reference testing laboratory (KRISS). The measurement equivalence was tested by the number of equivalence ($E_n$). If ${\mid}E_n{\mid}$ < 1, the measurement equivalence was established. All the participating laboratories passed this proficiency test.

Performance of Institute of Occupational Health, Korean Industrial Health Association in Proficiency Analytical Testing Program (대한산업보건협회 산업보건연구소의 PAT 정도관리 참여결과)

  • Lee, Jun-Seong;Yoo, Ho-Kyum;Oh, Mi-Soon;Park, Wha-Me;Yun, Gi-Sang;Choi, Ho-Chun;Chung, Kyou-Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.313-321
    • /
    • 1996
  • Our laboratoy has been participated in Proficiency Analytical Testing (PAT) program which is operated by the Americal Industrial Hygiene Association in cooperation with the National Institute for Occupational Safety and Health (NIOSH). The program is designed to assist a laboratory improve its analytical performance by providing samples on a quarterly basis, evaluating the results, and providing reports on how well the laboratory performed. Evaluation of the results reported here covers five rounds of the PAT program (round 121~round 125). The way a laboratory is evaluated by PAT program is as follows: 1) There is no overall proficiency rating given to a laboratory. 2) A proficiency rating is given for each type of analyze (i.e., metals, silica, asbestos, solvents) that a laboratory analyzed. 3) Proficiency is rated acceptable ("A") if Z score lies between -3 and +3, and unacceptable if Z score is either higher than +3 ("H") or lower than -3 ("Lo"). Z score = (reported data - reference value) / standard deviation 4) For a laboratory to be rated proficient it must either have had no outliers over the most recent two rounds or of the samples actually analyzed over the past year (past four rounds), 75 % or more of the analyze sample results must be acceptable. According to the above rating criteria of PAT program, performance of metals including cadmium, lead, chromium and zinc, and asbestos sample analyses were rated acceptable ("A"). For silica analyses, all samples except one out of four samples in round 122 was rated high("H") were acceptable showing 95 % of ing 95 % of acceptance rate (19/20) throughout the rounds. Analyses of organic solvents were done on 52 samples in 9 types including methanol(MOH), 1,1,1-trichloroethane(MCM), tetrachloroethylene(PCE), trichloroethylene(TCE), benzene(BNZ), o-xylene(OXY), toluene(TOL), chloroform(CFM), 1,2-dichloroethane(DCE). All samples analyzed were rated acceptable except 2 samples that were rated high; one out of each four MCM and TCE samples in round 121, and one that was low out of four o-xylene analyses in round 122 indicating 94 % of acceptance rate(49/52) throughout the rounds. According to the laboratory rating criteria, our laboratory is rated proficient so far for all types of contaminants.

  • PDF

Evaluation of the proficiency testing results for brominated flame retardants in high impact polystyrene (고충격폴리스티렌 중 브롬계 난연제 숙련도시험 결과 평가)

  • Kim, Dal-Ho;Ryu, Je-Hoon;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.435-442
    • /
    • 2011
  • Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) which have taken much interest recently due to their potential hazardous effects to human body and ecosystem. Many countries and European community prohibits the usage of certain BFRs in electronics and electronic devices (e.g. RoHS). In this perspectives, Korea Research Institute of Standards and Science (KRISS) has designed and practiced proficiency testing programs based on the ISO/IEC 17043 in order to assist laboratory accreditation activities. The programs for interlaboratory comparisons include congeners of PBDE (PBDE-154, 183, 206, 209) in high impact polystyrene (HIPS). A sample bottle that contains 10 g granular HIPS was distributed to 35 participating laboratories and the test results were calculated by the statistical procedure using z-scores to evaluate performance of each laboratory. The results and the laboratory's performance were discussed.