• Title/Summary/Keyword: Laboratory measurement

Search Result 1,944, Processing Time 0.033 seconds

Mycelial Growth and Fruiting Body Formation of Hericium erinaceum in Sawdust and Agricultural By-product Substrates (톱밥 및 농업부산물 이용 배지상에서 노루궁뎅이버섯(Hericium erinaceum)의 균사생장 및 자실체형성)

  • Ko, Han-Gyu;Park, Hyuk-Gu;Kim, Seong-Hwan;Park, Won-Mok
    • The Korean Journal of Mycology
    • /
    • v.32 no.2
    • /
    • pp.89-94
    • /
    • 2004
  • This study was carried out to investigate the suitability of various agricultural by-products as basal substrates for the mycelial growth and fruiting body formation of Hericium erinaceum. For this aim, oak sawdust, cotton waste, sugarcane bagasse, Job's tears, rice hull, Chinese cabbage, and coconut waste were used as sole or mixed substrate(s). Corn waste and rice bran were used as nutrient supplements. The growth and density of mycelium, yield of fruiting body, and biological efficiency were compared among tested substrates colonized by Hericium erinaceum. The best measurement of mycelial growth and density, yield of fruiting body, and biological efficiency in a laboratory test was found in a spawn substrate composed with oak sawdust 80% and rice bran 20%. The suitability of this spawn substrate composition for Hericium fruiting body production was testified through practical tests in plastic bottles (850 ml) in a mushroom farm which had bottle cultivation facility. However, test in a mushroom farm which had plastic bag cultivation facility, best production of Hericium fruiting body (520 g per one bag) was observed in a spawn substrate composed of cotton waste 40%, saw dust 40%, corn waste 10%, and rice bran 10%.

ESTIMATION OF CLEAR WOOD PROPERTIES BY NEAR INFRARED SPECTROSCOPY

  • Schimleck, Laurence R.;Evans, Robert;Ilic, Jugo;Matheson, A.Colin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1161-1161
    • /
    • 2001
  • Rapid cost-effective methods of measuring wood quality are extremely important to tree improvement programs where it is necessary to test large numbers of trees. Non-destructive sampling of a forest can be achieved by using increment cores generally removed at breast height. At CSIRO Forestry and Forest Products methods for the rapid, non-destructive measurement of wood properties and wood chemistry based on increment core samples have been developed. In this paper the application of near infrared (NIR) spectroscopy to the prediction of a range solid wood properties, including density, longitudinal modulus of elasticity (E$\sub$L/) and microfibril angle (MFA), is described. Experiments conducted on individual species (Eucalyptus delegatensis and Pinus radiata), the two species combined and a number of mixed species from several genera are reported. NIR spectra were obtained from the radial/longitudinal face of each sample and used to develop calibrations for the measured physical properties. When the individual species were used the relationships between laboratory determined data and NIR fitted data were good in all cases. Coefficients of determination (R$^2$) ranging from 0.77 for MFA to 0.93 for stick density were obtained for E. delegatensis and R$^2$ ranging from 0.68 for MFA to 0.94 for strip density were obtained for P. radiata. The calibration statistics for the combined E. delegatensis and P. radiata samples were similar to those found for the individual species. As these results indicated that it might be possible to produce general calibrations based on samples from a number of species of a single genus or samples from a number of different genera, a wide range of species was subsequently tested. Good relationships were obtained for both density and E$\sub$L/. These calibrations had R$^2$ that were slightly lower than those determined using individual species and standard errors that were higher. The mixed species calibrations, when applied to the E. delegatensis and P. radiata sample sets, provided good estimates of density (stick and strip) and E$\sub$L/. The results demonstrated that a mixed species calibration, that encompasses wide variation in terms of, wood anatomy, chemistry and physical properties, could be used to rank trees. Experiments reported in this paper demonstrate that solid wood properties can be estimated by NIR spectroscopy. The method offers a rapid and non-destructive alternative to traditional methods of analysis and is applicable to large-scale non-destructive forest resource assessment, and to tree breeding and silvicultural programs.

  • PDF

CHANGING THE ANIMAL WORLD WITH NIR : SMALL STEPS OR GIANT LEAPS\ulcorner

  • Flinn, Peter C.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1062-1062
    • /
    • 2001
  • The concept of “precision agriculture” or “site-specific farming” is usually confined to the fields of soil science, crop science and agronomy. However, because plants grow in soil, animals eat plants, and humans eat animal products, it could be argued (perhaps with some poetic licence) that the fields of feed quality, animal nutrition and animal production should also be considered in this context. NIR spectroscopy has proved over the last 20 years that it can provide a firm foundation for quality measurement across all of these fields, and with the continuing developments in instrumentation, computer capacity and software, is now a major cog in the wheel of precision agriculture. There have been a few giant leaps and a lot of small steps in the impact of NIR on the animal world. These have not been confined to the amazing advances in hardware and software, although would not have occurred without them. Rapid testing of forages, grains and mixed feeds by NIR for nutritional value to livestock is now commonplace in commercial laboratories world-wide. This would never have been possible without the pioneering work done by the USDA NIR Forage Research Network in the 1980's, following the landmark paper of Norris et al. in 1976. The advent of calibration transfer between instruments, algorithms which utilize huge databases for calibration and prediction, and the ability to directly scan whole grains and fresh forages can also be considered as major steps, if not leaps. More adventurous NIR applications have emerged in animal nutrition, with emphasis on estimating the functional properties of feeds, such as in vivo digestibility, voluntary intake, protein degradability and in vitro assays to simulate starch digestion. The potential to monitor the diets of grazing animals by using faecal NIR spectra is also now being realized. NIR measurements on animal carcasses and even live animals have also been attempted, with varying degrees of success, The use of discriminant analysis in these fields is proving a useful tool. The latest giant leap is likely to be the advent of relatively low-cost, portable and ultra-fast diode array NIR instruments, which can be used “on-site” and also be fitted to forage or grain harvesters. The fodder and livestock industries are no longer satisfied with what we once thought was revolutionary: a 2-3 day laboratory turnaround for fred quality testing. This means that the instrument needs to be taken to the samples rather than vice versa. Considerable research is underway in this area, but the challenge of calibration transfer and maintenance of instrument networks of this type remains. The animal world is currently facing its biggest challenges ever; animal welfare, alleged effects of animal products on human health, environmental and economic issues are difficult enough, but the current calamities of BSE and foot and mouth disease are “the last straw” NIR will not of course solve all these problems, but is already proving useful in some of these areas and will continue to do so.

  • PDF

Overview of new developments in satellite geophysics in 'Earth system' research

  • Moon Wooil M.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.3-17
    • /
    • 2004
  • Space-borne Earth observation technique is one of the most cost effective and rapidly advancing Earth science research tools today and the potential field and micro-wave radar applications have been leading the discipline. The traditional optical imaging systems including the well known Landsat, NOAA - AVHRR, SPOT, and IKONOS have steadily improved spatial imaging resolution but increasing cloud covers have the major deterrent. The new Earth observation satellites ENVISAT (launched on March 1 2002, specifically for Earth environment observation), ALOS (planned for launching in 2004 - 2005 period and ALOS stands for Advanced Land Observation Satellite), and RADARSAT-II (planned for launching in 2005) all have synthetic aperture radar (SAR) onboard, which all have partial or fully polarimetric imaging capabilities. These new types of polarimetric imaging radars with repeat orbit interferometric capabilities are opening up completely new possibilities in Earth system science research, in addition to the radar altimeter and scatterometer. The main advantage of a SAR system is the all weather imaging capability without Sun light and the newly developed interferometric capabilities, utilizing the phase information in SAR data further extends the observation capabilities of directional surface covers and neotectonic surface displacements. In addition, if one can utilize the newly available multiple frequency polarimetric information, the new generation of space-borne SAR systems is the future research tool for Earth observation and global environmental change monitoring. The potential field strength decreases as a function of the inverse square of the distance between the source and the observation point and geophysicists have traditionally been reluctant to make the potential field observation from any space-borne platforms. However, there have recently been a number of potential field missions such as ASTRID-2, Orsted, CHAMP, GRACE, GOCE. Of course these satellite sensors are most effective for low spatial resolution applications. For similar objects, AMPERE and NPOESS are being planned by the United States and France. The Earth science disciplines which utilize space-borne platforms most are the astronomy and atmospheric science. However in this talk we will focus our discussion on the solid Earth and physical oceanographic applications. The geodynamic applications actively being investigated from various space-borne platforms geological mapping, earthquake and volcano .elated tectonic deformation, generation of p.ecise digital elevation model (DEM), development of multi-temporal differential cross-track SAR interferometry, sea surface wind measurement, tidal flat geomorphology, sea surface wave dynamics, internal waves and high latitude cryogenics including sea ice problems.

  • PDF

Effects of Sintering Temperature and SiC Contents on the Microstructure and Superconducting Properties of In-situ $MgB_2$ Wires (In-situ $MgB_2$ 선재의 소결온도와 SiC 함량에 따른 미세조직 및 초전도 특성 연구)

  • Hwang, Soo-Min;Park, Eui-Cheol;Park, Si-Hong;Jang, Seok-Hern;Kim, Kyu-Tae;Lim, Jun-Hyung;Joo, Jin-Ho;Kang, Won-Nam;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.68-73
    • /
    • 2007
  • We fabricated the in-situ $MgB_2$ wires using the powder-in-tube method and investigated the effects of sintering temperature and SiC contents on the microstructure and superconducting properties. Pure $MgB_2$ wires and 5, 10, 20 wt.% SiC doped $MgB_2$ wires were sintered at $600-1000^{\circ}C$ for 30 minutes in Ar atmosphere. We found that $MgB_2$ phase was mostly formed at the sintering temperature of $700^{\circ}C$ and above, and the critical temperature ($T_c$) increased with increasing sintering temperature. For the $MgB_2$ sintered at $850^{\circ}C$, the highest critical current density ($J_c$) was obtained to be $3.7{\times}10^5\;A/cm^2$ at 5 K and 1.6 T by a magnetic properties measurement system (MPMS). The addition of SiC to the $MgB_2$ wires changed microstructure and critical properties. SEM observation showed that the $MgB_2$ core had considerable micro-cracks in undoped wire and the density of micro-cracks decreased with increasing SiC contents. The critical temperature decreased as the SiC contents increased, on the other hand, the critical current density of SiC doped $MgB_2$ wires in high magnetic field was enhanced compared to that of undoped $MgB_2$ wires.

  • PDF

Flow Cytometric Characterization of Lymphocyte Subpopulations in Mice Infected with Clonorchis sinensis (간흡충 항원에 의한 마우스 비장 림프구의 아형 특성)

  • Yong-Suk Ryang;In-Soon Shin;Yung-Kyum Ahn
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 1996
  • A Recent discovery of surface antigens in cells has led to the success of quantitative measurement of T-cell subpopulations, and this has especially opened the way for an epoch-making development in the understanding and classification of cellular immune mechanisms. It is known that phenotypes of T-cell subpopulations exist in many forms according to the variation of species or animal experimental models. In Korea, Clonorchis sinensis still gives rise to public concern as it infects more than eighty million people and threatens the public by causing cirrhosis of the liver, or liver cancer when liver infection becomes prolonged and chronic. Up until now there has been much progress in research and improvement in the classification system of Clonorchis sinensis in the area of humoral immunity, but as for research in the area of cellular immune mechanisms, there is almost none. Knowing all these circumstances, the authors delved for the characterization of Iymphocyte subpopulations with mice as Clonorchis sinensis in the area of cellular immunity, and obtained the following results. That is, we injected Clonorchis sinensis antigens mixed in Freund's ajuvant solution intraperitoneally in mice and measured the T-cell subpopulation characterization of spleen lymphocytes with flow cytometry. The results of these measurements showed that CD2, CD5 and CD8 decreased early following injections but then in-creased again seven weeks after the injections. CD4, however, showed a slight increase shortly after the injection but then a fair increase seven weeks after the injection.

  • PDF

Channel and Data Analysis System for Digital TV Broadcasting Using Modified Hilbert Transform (변형된 힐버트 변환을 이용한 디지털 TV 방송 채널 및 데이터 분석 시스템)

  • Suh, Young-Woo;Lee, Jae-Kwon;Mok, Ha-Kyun;Choi, Jin-Yong;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.438-449
    • /
    • 2009
  • To analyze reception environments of ATSC Digital TV, CIR (Channel Impulse Response) analysis systems are widely applied. The receiving performances of conventional CIR analysis systems are not as good as those of commercial state-of-the-art receivers. There are difficulties in measuring and analyzing reception problems caused by multi-path interferences. To solve these problems, commercial DTV chip sets embedded CIR analysis system is proposed. Generally, commercial chip sets provide baseband (In-phase) channel data and field or segment sync data. For more precise analysis of measured I channel data, it is necessary to extract Q (quadrature) channel data components as well. This paper presents the technical requirements of CIR analysis system for DTV. In order to satisfy such requirements and measure more accurate magnitude and phase of CIR, a method to derive the quadrature data from the measured in-phase channel data is proposed. The proposed channel analysis system is implemented with a commercial DTV chip set and expedites the data analysis for use on DTV field test vehicles. Computer simulation and laboratory test results are provided to demonstrate the performance of the proposed channel analysis system.

Carotid Intima-Media Thickness Measurement in Obese Children (비만 소아들에서의 경동맥 내막중막 두께 측정)

  • Park, Kyung Ok;Choi, Suk Ju;Yeom, Hee Hyun;Chung, Sochung;Yu, Jeong Jin;Park, Youngshin;Lee, Dong Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.935-938
    • /
    • 2005
  • Purpose : The aim of the present study was to ascertain whether the increase of carotid intima-media thickeness(cIMT) as one of premature pathologic changes of atherosclerosis, was present in obese children compared to normal weight children. Methods : The obese group consisted of 21 obese/overweight(body mass index(BMI) above 85 percentile of age, sex standards) children and the control group of 11 normal weight children. None of the children had any chronic illnesses or previous medication history. We investigated the age, sex, height, weight, and systolic/diastolic blood pressure. We measured cIMT by ultrasonogram. In 19 of the obese group, we tested the serum glucose level, liver transaminase level, and cholesterol level etc. Results : The increase of cIMT in obese group did not achieved statistical significance(obese group vs. control group; 0.42 vs. 0.40 mm, P=0.0592). In addition, cIMT showed no significant correlation with any physical/laboratory variables including BMI(P=0.0585). Conclusion : To our knowledge, this is the first study to measure the cIMT in Korean children. Though the results approached statistical significance, we could not prove an increase of cIMT in obese children or an association between cIMT and BMI, due to the study's small sample size. In the future, larger and more extensive trials are needed.

INTEGRATED RAY TRACING MODEL FOR END-TO-END PERFORMANCE VERIFICATION OF AMON-RA INSTRUMENT (AMON-RA 광학계를 활용한 통합적 광선 추적 기법의 지구 반사율 측정 성능 검증)

  • Lee, Jae-Min;Park, Won-Hyun;Ham, Sun-Jeong;Yi, Hyun-Su;Yoon, Jee-Yeon;Kim, Sug-Whan;Choi, Ki-Hyuk;Kim, Zeen-Chul;Lockwood, Mike
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • The international EARTHSHINE mission is to measure 1% anomaly of the Earth global albedo and total solar irradiance using Amon-Ra instrument around Lagrange point 1. We developed a new ray truing based integrated end-to-end simulation tool that overcomes the shortcomings of the existing end-to-end performance simulation techniques. We then studied the in-orbit radiometric performance of the breadboard Anon-Ra visible channel optical system. The TSI variation and the Earth albedo anomaly, reported elsewhere, were used as the key input variables in the simulation. The output flux at the instrument focal plane confirms that the integrated ray tracing based end-to-end science simulation delivers the correct level of incident power to the Amon-Ra instrument well within the required measurement error budget of better than ${\pm}0.28%$. Using the global angular distribution model (ADM), the incident flux is then used to estimate the Earth global albedo and the TSI variation, confirming the validity of the primary science cases at the L1 halo orbit. These results imply that the integrated end-to-end ray tracing technique, reported here, can serve as an effective and powerful building block of the on-line science analysis tool in support of the international EARTHSHINE mission currently being developed.

Development of an Electro Impedance Spectroscopy device for EDLC super capacitor characterization in a mass production line (EDLC 슈퍼 캐피시터 특성 분석을 위한 양산용 전기화학 분석 장치 개발)

  • Park, Chan-Hee;Lee, Hye-In;Kim, Sang-Jung;Lee, Jung-Ho;Kim, Sung-Jin;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5647-5654
    • /
    • 2012
  • In this paper, we developed an electro impedance spectroscopy (EIS) device, which are primarily used for the analysis of fuel cells or batteries, to widen its coverage to the next generation super capacitor EDLC characterization. The developed system was composed of a signal generator that can generate various signal patterns, a potentiostatic generator, and a high speed digital filter for signal processing and measurement program. The developed system is portable, which is not only suitable laboratory use but also for mass production line. The special features of the system include a patterned output signal from 0.01 to 20 kHz, and a fast Fourier transform (FFT) analysis of current signals, both of which are acquired simultaneously. Our tests showed similar results after comparing the analysis from our newly-developed device showing the characteristics of EDLC complex impedance and the analysis from an equivalent impedance which was applied to an equivalent circuit. Now, we can expect a fast inspection time from the application of the present system to the super capacitor production line, based on time-varying changes in electrochemical impedance.