• 제목/요약/키워드: Laboratory measurement

검색결과 1,944건 처리시간 0.028초

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Automated measurement of tool wear using an image processing system

  • Sawai, Nobushige;Song, Joonyeob;Park, Hwayoung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.311-314
    • /
    • 1995
  • This paper presents a method for measuring tool wear parameters based on two dimensional image information. The tool wear images were obtained from an ITV camera with magnifying and lighting devices, and were analyzed using image processing techniques such as thresholding, noise filtering and boundary tracing. Thresholding was used to transform the captured gray scale image into a binary image for rapid sequential image processing. The threshold level was determined using a novel technique in which the brightness histograms of two concentric windows containing the tool wear image were compared. The use of noise filtering and boundary tracing to reduce the measuring errors was explored. Performance tests of the measurement precision and processing speed revealed that the direct method was highly effective in intermittent tool wear monitoring.

  • PDF

Measurements of a microchannel flow using micro-PIV

  • Lee Inwon;Choi Jayho;Lee In-Seop
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.44-52
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.8\;\times\;6.8{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

ERA 부분방전 측정시스템의 측정불확도개선 (Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory)

  • 허종철;김위영;김석수;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

Thermal Strain Measurement of Austin Stainless Steel (SS304) during a Heating-cooling Process

  • Ha, Ngoc San;Le, Vinh Tung;Goo, Nam Seo;Kim, Jae Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.206-214
    • /
    • 2017
  • In this study, measurement of thermophysical properties of materials at high temperatures was performed. This experiment employed a heater device to heat the material to a high temperature. The images of the specimen surface due to thermal load at various temperatures were recorded using charge-coupled device (CCD) cameras. Afterwards, the full-field thermal deformation of the specimen was determined using the digital image correlation (DIC) method. The capability and accuracy of the proposed technique are verified by two experiments: (1) thermal deformation and strain measurement of a stainless steel specimen that was heated to $590^{\circ}C$ and (2) thermal expansion and thermal contraction measurements of specimen in the process of heating and cooling. This research focused on two goals: first, obtaining the temperature dependence of the coefficient of thermal expansion, which can be used as data input for finite element simulation; and second, investigating the capability of the DIC method in measuring full-field thermal deformation and strain. The results of the measured coefficient of thermal expansion were close to the values available in the handbook. The measurement results were in good agreement with finite element method simulation results. The results reveal that DIC is an effective and accurate technique for measuring full-field high-temperature thermal strain in engineering fields such as aerospace engineering.

TLD를 이용한 X-선 수중 흡수선량 측정 및 해석 (Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD)

  • 오장진;전재식;하석호;김원식;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.21-28
    • /
    • 1988
  • LiF : PTEE를 사용하여 중경 X-선(HVL : 0,29, 0.84, 1.60, 2.62mmCu) 영역에 대한 수중 흡수선량을 측정 해석하였다. 이때 선량계 (0.4mm ${\times}\;{\phi}$12.5mm, hot-pressed LiF TLD-700)는 루사이트로 둘러 싸여 있고 물의 흡수선량은 각각의 TL출력 값에 Burlin의 공동이론을 적용하여 해석하였다. 그 결과 물 팬텀 속 깊이 5cm에서 흡수선량률의 측정 오차는 최대 ${\pm}5%$로 나타났다. 이 측정값을 측정 오차가 ${\pm}2%$의 간접절대측정방법인 이온화법에 의한 측정값과 비교한 결과 두 값의 차이는 LiF : PTFE의 측정오차 범위 내에서 일치하였다. 이와같은 결과로 LiF : PTFE를 이용한 수중 흡수선량 측정의 신뢰성을 확인할 수 있게 되었으며 이는 중경 X-선 영역에 대한 선량당량 평가의 근거로 활용 될 수 있을 것이다.

  • PDF

차음성능 측정시 터널링 효과에 관한 연구 (A Study on Tunneling Effect in Sound Transmission Loss Measurement)

  • Kim, Bong-Ki;Kim, Jae-Seung;Kim, Hyun-Sil;Kang, Hyun-Ju;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • 제23권1E호
    • /
    • pp.24-30
    • /
    • 2004
  • This study is aimed to evaluate a tunneling effect in the laboratory measurement of sound transmission loss. Based on the formulation for sound transmission loss of a finite panel in the presence of tunnel, variations of the sound transmission loss with the parameters of panel location and tunnel depth are investigated. In comparison with the transmission loss of a finite plate in an infinite rigid baffle, the maximum difference occurs in the laboratory measurement when the panel is placed at the center of the tunnel, while a better estimation of true transmission loss is obtained when the panel is located at either end.

Scanning Rayleigh Doppler Lidar for Wind Profiling Based on Non-polarized Beam Splitter Cube Optically Contacted FPI

  • Zheng, Jun;Sun, Dongsong;Chen, Tingdi;Zhao, Ruocan;Han, Yuli;Li, Zimu;Zhou, Anran;Zhang, Nannan
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.195-202
    • /
    • 2018
  • A Scanning Rayleigh Doppler lidar for wind profiling based on a non-polarized beam splitter cube optically contacted FPI is developed for wind measurement from high troposphere to low stratosphere in 5-35 km. Non-polarized beam splitter cube optically contacted to the FPI are used for a stable optical receiver. Zero Doppler shift correction is used to correct for laser or FPI frequency jitter and drift and the timing sequence is designed. Stability of the receiver for Doppler shift discrimination is validated by measuring the transmissions of FPI in different days and analyzed the response functions. The maximal relative wind deviation due to the stability of the optical receiver is about 4.1% and the standard deviation of wind velocity is 1.6% due to the stability. Wind measurement comparison experiments were carried out in Jiuquan ($39.741^{\circ}N$, $98.495^{\circ}E$), Gansu province of China in 2015, showing good agreement with radiosonde result data. Continuous wind field observation was performed from October 16th to November 12th and semi-continuous wind field of 19 nights are presented.

3차 교차상관신호의 역상관을 통한 펨토초 및 처프된 피코초 펄스의 정확한 선행펄스 대비율 측정 (Accurate Contrast-ratio Measurement of Femtosecond and Chirped Picosecond Pulses from the Decorrelation of Third-order Correlation Trace)

  • Hong, Kyung-Han;Sung, Jae-Hee;Yu, Tae-Jun;Choi, Il-Woo;Kim, Hyung-Taek;Noh, Young-Chul;Ko, Do-Kyeong;Lee, Jong-Min
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 동계학술발표회 논문집
    • /
    • pp.349-350
    • /
    • 2007
  • PDF