• Title/Summary/Keyword: Laboratories of University

Search Result 1,471, Processing Time 0.03 seconds

Estimation of Fetal Dose during Radiation Therapy of Pregnant Patient (임산부의 방사선치료 시 태아선량 평가)

  • Jung, Chi-Hoon;Kim, Chan-Yong;Kim, Bo-Gyum;Seo, Suk-Jin;Yoo, Sook-Hyun;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Purpose: To evaluate the effectiveness of a simple and practical shielding device to reduce the fetal dose for a pregnant patient undergoing radiation therapy of brain metastasis. Materials and Methods: The dose to the fetus was evaluated by simulating the treatments using the anthropomorphic phantom. The prescription dose at mid-brain is $300cGy{\times}10$ fractions with 6 MV photon with $18{\times}22cm^2$ field size. The additional shielding devices to reduce the fetal dose are a shielding wall, cerrobend plates and lead (Pb) sheets over acrylic bridge. Various points of measurement with off-field distance were detected by using ion-chamber (30, 40, 50, and 60 cm) with and without the shielding devices and TLD (30, 40, 50, 60, and 70 cm) only with the shielding devices. Results: The doses to the fetus without shielding were 3.20, 3.21, 1.44, 0.90 cGy at the distances of 30, 40, 50, and 60 cm from the treatment field edge. With shielding, the doses were reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy (70 cm). The total dose to the fetus was expected to be under 1 cGy during the entire treatment. Conclusion: The essential point during radiation therapy of pregnant patient would be minimizing the fetal dose. 10 cGy to 20 cGy is the threshold dose for fetal radiation effects. Our newly developed device reduced the fetal dose far below the safe level. Therefore, our additional shielding devices are useful and effective to reduce the fetal dose.

  • PDF

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

Serological Survey for the Major Viral Diseases in the Layers (국내 산란계의 주요 바이러스성 질병에 대한 혈청학적 모니터링 결과 및 분석)

  • Lee, Hae-Rim;Kim, Jong-Man;Kim, Jin-Hyung;Kim, Chang-Moon;So, Hyun-Hee;Lee, Dong-Woo;Ha, Bong-Do;Hong, Song-Chol;Mo, In-Pil
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.361-372
    • /
    • 2010
  • Serological evaluation for the poultry is important for various reasons, such as designing and assessing the vaccination program and diagnosing diseases and for this reason, serologic tests for the layer flocks have been conducted on a regular basis. Moreover, the nationwide serological survey and analysis are essential to understand the epidemiological status of national poultry industry. In this sense, the study was conducted to evaluate the immune status of the layer flocks with the sera submitted to Avian Disease Laboratory, Chungbuk National University in 2009, and several important viral diseases were selected for evaluation including low pathogenic avian influenza (LPAI), Newcastle disease (ND), infectious bronchitis (IB) and avian metapneumovirus (aMPV). For LPAI and ND, the age-related patterns of geometric mean titer (GMT) changes were similar but there were differences in the flock positive rate and the level of GMT due to the different vaccination policy. In the case of IB, the values of GMT showed that the field infection was more prevalent than expected. For aMPV, positive birds in a flock increased as the layers got older, which reflected the course of field infection because vaccination against aMPV was not allowed in 2009. From this study, the immune status for the main viral diseases in layers became more clarified but this information was limited because of only one year study. Therefore, serological survey needs to be conducted on a yearly basis and furthermore include broilers and breeders for a better understanding of the health status in the national poultry industry.

Consideration About the Bacterial Endotoxin Test Showing False Positive Test Result When Performing LAL Test (LAL Test에서 위양성을 나타내는 원인들에 대한 고찰)

  • Hwang, Ki-Young;Cho, Yong-Hyun;Lee, Yong-Suk;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.156-158
    • /
    • 2009
  • Purpose: Since radiopharmaceuticals are intended for human administration, it is imperative that we should undergo quality control very strictly. Now almost all the PET laboratories have adopted Bacterial Endotoxin Test as the stand quality control method to monitor whether pyrogen is free or not in the product vial containing crude solution. The aim of this study is to find out the reason why false positive result is observed when using commercially available test vial. Materials and Methods: For this experiment, we used commercially available single test kit (Associates of Cape Code. Inc. USA) and we made pH samples by mixing each buffer whose pH ranges are 1.0 to 12.0. Otherwise we made Ethanol samples diluted with distilled water. After making test samples, it added 0.2 mL to the test vial. Assay mixture in the test vial was incubated in a water bath (Chang Shin Co. KOR) for 60 min at $35{\pm}2^{\circ}C$. Results: After incubation period ($60{\pm}1^{\circ}C$), we inverted the test vial about $180^{\circ}$ To know what pH and how many percentage of Ethanol (Fisher Scientific Korea. Ltd) will affect the reaction. With pH buffer, false positive result was observed at pH 1.0 to 5.0 and 7.7 to 12.6 but at pH 5.2 to.7.5, the test results show negative. It's very strange that we couldn't observe negative test result with Tris buffer at pH 8.4, 8.6, 8.8, 9.0. in other case Ethanol, the test result was seen with 5 to 10% Ethanol. But to my surprise we could see very thick gel formation with 100% Ethanol. Conclusions: In this study, we could notice that pH which is too much acidic or alkalic or high concentrated Ethanol would affect Bacterial Endotoxin Test result. As you know, LAL test is sensitive and very reliable method. Therefore, we are needed to elicit the accurate test result as possible as we can.

  • PDF

Production of Poly-3-hydroxybutyrate from Xylose by Bacillus megaterium J-65 (Bacillus megaterium J-65에 의한 xylose로부터 poly-3-hydroxybutyrate 생산)

  • Jun, Hong-Ki;Jin, Young-Hi;Kim, Hae-Nam;Kim, Yun-Tae;Kim, Sam-Woong;Baik, Hyung-Suk
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1625-1630
    • /
    • 2008
  • A microorganism capable of producing high level of poly-3-hydoxybutyrate (PHB) from xylose was isolated from soil. The isolated strain J-65 was identified as Bacillus megaterium based on the morphological, biochemical and molecular biological characteristics. The optimum temperature and pH for the growth of B. megaterium J-65 were $37^{\circ}C$ and 8.0, respectively. The optimum medium composition for the cell growth was 2% xylose, 0.25% $(NH_4)_2SO_4$, 0.3% $Na_2HPO_4{\cdot}12H_2O$, and 0.1% $KH_2PO_4$. The optimum condition for PHB accumulation was same to the optimum condition for cell growth. Copolymer of ${\beta}$-hydroxybutyric and ${\beta}$-hydroxyvaleric acid was produced when propionic acid was added to shake flasks containing 20 g/l of xylose. Fermenter culture was carried out to produce the high concentration of PHB. In batch culture, cell mass was 9.82 g/l and PHB content was 35% of dry cell weight. PHB produced by B. megaterium J-65 was identified as homopolymer of 3-hydoxybutyric acid by GC and NMR.

The Recognition of teachers and students on clothing department education in vocational high school (전문계 고등학교 의상과 교육에 대한 교사와 학생의 인식)

  • Jang, Ja-Kyung;Shin, Hye-Won
    • Journal of Korean Home Economics Education Association
    • /
    • v.21 no.4
    • /
    • pp.71-89
    • /
    • 2009
  • The purpose of this paper was to suggest effective management of clothing department in vocational high schools. Bibliographic research on ten vocational high schools' clothing departments was done. Also a survey was done to figure out what students and teachers think of clothing department education. The results were as follows. There are ten clothing departments in vocational high schools countrywide. 1493 students are enrolled in the department and they are taught by 51 teachers. Each school has two to seven laboratories. Professional subject time assignment of clothing department varies from 82 to 112 hours. Students chose clothing department in order to enter the university and their satisfaction on the department was "fair." Students' satisfaction level of professional education courses was "fair" and they felt difficulties both in theory and practice. Students answered that Embroidery/Knitting courses should be closed and Fashion Coordination be opened. Students were "fairly" satisfied with facilities for practice and felt job training was necessary. Most of them wanted to enter university after high school graduation. Teachers answered professional education curriculum was "fair." They found it necessary to improve the textbooks and felt both theory and practice difficult. They wanted Embroidery/Knitting courses to be closed and Fashion CAD course to be installed. From the teachers' view, students' prospect was better to enter university than to get a job. Teachers suffered from too much teaching-unrelated workload and wanted the number of teachers to be increased. Considering the above results, vocational high schools should concentrate their efforts on making students continue to study by extending the way to enter the same department of university as department of vocational high schools. In addition, they should develop various practice programs through field practice and educational-industrial relationship to help students get jobs. Both teachers and students think that the clothing department curriculum is difficult now. Therefore, the level of the curriculum should be adjusted. Finally, it was necessary to increase the number of teachers and to carry out teachers' training to raise quality in education.

  • PDF

An Analysis of Teachers' Level of Usage and Concern Over the 7th Science Curriculum (제7차 과학 교육과정에 대한 지구과학 교사들의 관심도와 활용도 분석)

  • Lee, Yong-Seob;An, Hyun-Hee;Kim, Sang-Dal;Kim, Jong-Hee
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.378-392
    • /
    • 2003
  • The purpose of this study is to investigate the depth of earth science teachers' concern over the 7th Science Curriculum and levels of their use of it in reality, using the tools "Concern" and "Levels of use" which are two important tools use in CBAM. The results of the study are as follows. How much concern do the earth science teachers have over the 7th Science Curriculum? There are seven stages (from 0 stage to 6 stage) of teachers' concern over the curriculum. o stage represents teachers' indifference to the curriculum and 98% teachers are placed in this stage. According to the study on teachers' teaching experience, teachers having from 10 to 14 years of teaching experience are the most indifferent to the 7th Science Curriculum, compared to other teachers. Which levels of use of the 7th science curriculum do earth science teachers choose in reality? There are five levels of use (from 1 to 5) of the 7th curriculum. 43.97% of teachers are placed in the 3rd level called "Mechanical level", which represents a teacher-concerned learning method with consideration of learners' response. According to the study on teachers' frequency of level of use in the fields of "Instruction objects, Instruction contents, Instruction methods, Instruction materials and Evaluation.", teachers chose high levels of use in the fields of "Instruction objects and Instruction contents" and low levels of use in the other three fields. What factors are barriers for earth science teachers to perform the 7th Science Curriculum in reality? 80.9% of teachers have trouble performing the 7th Science Curriculum in reality because of too much routine work, official papers, and lack of instructional materials, laboratories, training systems and workshops. The two biggest barriers among the above are routine work and of official papers. According to the study on teachers' teaching experience, teachers having from 0 to years of teaching experience have the most trouble in performing the curriculum in reality, compared to other teachers.

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

Absorption of Carbon Dioxide into Aqueous Potassium Salt of Serine (Serine 칼륨염 수용액의 이산화탄소 흡수특성)

  • Song, Ho-Jun;Lee, Seung-Moon;Lee, Joon-Ho;Park, Jin-Won;Jang, Kyung-Ryong;Shim, Jae-Goo;Kim, Jun-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.505-514
    • /
    • 2009
  • Aqueous potassium salt of serine was proposed as an alternative $CO_2$ absorbent to monoethanolamine (MEA) and its $CO_2$ absorption characteristics were studied. The experiment has been conducted using screening test equipment with NDIR type gas analyzer and vapor-liquid equilibrium apparatus. $CO_2$ absorption/desorption rate and net amount of $CO_2$ absorbed in cyclic process are the criteria to assess the $CO_2$ absorption characteristics in this study. Effective $CO_2$ loading of potassium salt of serine and MEA are 0.425 and 0.230 respectively. Cyclic capacities are 0.354 and 0.298 for potassium salt of serine and MEA. The absorption rate of the potassium serinate decreased sharply at $CO_2$ loading is 0.1 and were maintained approximately at half of MEA. To enhance the absorption rate of aqueous potassium salt of serine, small quantities of rate promoters, namely piperazine and tetraethylenepentamine were blended, so that rich $CO_2$ loading were increased by 13.7% and 18.7% respectively. The rich $CO_2$ loading of potassium salt of serine was 29.2% and 35.0% higher than those of aqueous sodium and lithium salt of serine, respectively. The absorption rate of potassium salt of valine and isoleucine which have similar molecular structures to serine were lower than that of serine because of the presence of bulky side group. Precipitation phenomena during $CO_2$ absorption were discussed by the aid of literatures.

Immunohistochemical study of the gastrointestinal endocrine cells in the Mongolian Gerbils, Meriones unguiculatus (몽골리안 저빌(Meriones unguiculatus)의 위장관 내분비 세포에 대한 면역조직화학적 연구)

  • Lee, Jae-hyun;Lee, Hyeung-sik;Ku, Sae-kwang;Park, Ki-dae;Kim, Kil-soo
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.653-660
    • /
    • 2000
  • In order to study the regional distribution and relative frequency of the immunoreactive endocrine cells in the gastrointestinal tract of the Mongolian gerbil, Meriones unguiculatus, the gastrointestinal tract was divided into 9 portions (cardia, fundus, pylorus, duodenum, jejunum, ileum, cecum, colon and rectum) and immunostained by immunohistochemical (PAP) method using 8 types of specific antisera against cholecystokinin (CCK)-8, gastrin, secretin, pancreatic polypeptide(PP), somatostatin, serotonin, glucagon and insulin. CCK-8-, gastrin-, somatostatin- and serotonin-immunoreactive cells were demonstrated in this study. These immunoreactive cells were found in the gastric gland regions of the pylorus or between parietal and chief cells of the fundus with round to spherical shaped, and in the interepithelial regions of the intestinal tract with spherical to spindle shaped except for jejunum where some of immunoreactive cells were also observed in the intestinal glands with round to spherical shaped. CCK-8-immunoreactive cells were restricted to the pylorus and duodenum with numerous and a few frequency, respectively. Gastrin-immunoreactive cells were restricted to the pylorus with numerous frequency. Similar to those of gastrin-immunoreactive cells, somatostatin-immunoreactive cells were restricted to pylorus with moderate frequency. Serotonin-immunoreactive cells were detected throughout whole gastrointestinal tract except for cardia and cecum with moderate or numerous frequency. However, no secretin-, PP-, glucagon- and insulin-immunoreactive cells were observed in this study. From these results, the appearance type, regional distribution and relative frequency of immunoreactive endocrine cells in the gastrointestinal tract of the Mongolian gerbils were somewhat lowered or restricted compared to those of other mammals and these differences were might be caused by feeding habits and species specification.

  • PDF