• Title/Summary/Keyword: LVP

Search Result 15, Processing Time 0.031 seconds

Purification, Structural Characterization, and Biological Activity of Polysaccharides from Lentinus velutinus

  • Udchumpisai, Wascharin;Bangyeekhun, Eakaphun
    • Mycobiology
    • /
    • v.48 no.1
    • /
    • pp.51-57
    • /
    • 2020
  • A polysaccharide (LVP) was purified from fruiting body of Lentinus velutinus by ethanol precipitation fractionation and DEAE and Sephadex G-100 column chromatography. The yield of purified polysaccharide was 0.025%. Molecular characteristics of LVP were determined by gel permeation chromatography, FT-IR spectroscopy, and thin-layer chromatography. Our results revealed that LVP is a polysaccharide composed of only glucose units, and has a molecular weight of 336 kDa. Biological activity assays indicated that LVP exhibits both cytotoxic and antioxidant activity. LVP showed specific cytotoxicity against cancer cells (HeLa and HepG2 cells), and alterations in cancer cell morphology were found after LVP treatment.

The Electrochemical Performance of Li3V2(PO4)3/Graphene Nano-powder Composites as Cathode Material for Li-ion Batteries

  • Choi, Mansoo;Kim, Hyun-Soo;Lee, Young Moo;Jin, Bong-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.109-114
    • /
    • 2014
  • The $Li_3V_2(PO_4)_3$/graphene nano-particles composite was successfully synthesized by a facile sol-gel method. The addition of a graphene in $Li_3V_2(PO_4)_3(LVP)$(LVP) showed the high crystallinity and influenced the morphology of the $Li_3V_2(PO_4)_3$ particles observed in X-ray diffraction (XRD) and scanning electron microscopy (SEM). The LVP/graphene samples were well connected, resulting in fast charge transfer. The effect of the addition graphene nano-particles on electrochemical performance of the materials was investigated. Compared with the pristine LVP, the LVP/graphene composite delivered a higher discharge capacity of $122mAh\;g^{-1}$ at 0.1 C-rate, better rate capability and cyclability in the potential range of 3.0-4.3 V. The electrochemical impedance spectra (EIS) measurement showed the improved electronic conductivity for the LVP/graphene composite, which can ensure the high specific capacity and rate capability.

Moderating Effect of Luxury Value Perceptions in the Relationship between In-Store Emotions and Perceived Brand Luxury

  • Lee, Eun-Jung;Kim, Hanna
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.1
    • /
    • pp.81-96
    • /
    • 2016
  • The meaning of luxury varies by individuals. The differing luxury perceptions should influence the way individuals react to relevant marketing programs for luxury. Limited research exists on the topic despite interest in luxury segmentation and consumer-oriented values for luxury in marketplaces. Referring to the conceptual framework by Wiedmann et al. (2007), we explored the moderation role of four dimensions of luxury value perceptions (LVP; financial, functional, individual, and social dimensions), in the relationship between in-store emotion and perceived brand luxury. A total of 218 U.S. consumers participated in our online survey using a hypothetical luxury store image. The results revealed the following: First, on the relationship between felt pleasure and perceived brand luxury (PBL), the financial dimension of LVP only showed a significant moderation effect. Second, the effect of felt arousal on PBL was moderated by the financial and social dimensions of LVP. Lastly, the individual dimension of LVP only moderated the relationship between felt dominance and PBL. Theoretical and managerial implications are suggested.

Fabrication and Characterization of Spherical Carbon-Coated Li3V2(PO4)3 Cathode Material by Hydrothermal Method with Reducing Agent

  • Moon, Jung-In;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.29 no.9
    • /
    • pp.519-524
    • /
    • 2019
  • Spherical $Li_3V_2(PO_4)_3$ (LVP) and carbon-coated LVP with a monoclinic phase for the cathode materials are synthesized by a hydrothermal method using $N_2H_4$ as the reducing agent and saccharose as the carbon source. The results show that single phase monoclinic LVP without impurity phases such as $LiV(P_2O_7)$, $Li(VO)(PO_4)$ and $Li_3(PO_4)$ can be obtained after calcination at $800^{\circ}C$ for 4 h. SEM and TEM images show that the particle sizes are $0.5{\sim}2{\mu}m$ and the thickness of the amorphous carbon layer is approximately 3~4 nm. CV curves for the test cell are recorded in the potential ranges of 3.0~4.3 V and 3.0~4.8 V at a scan rate of $0.01mV\;s^{-1}$ and at room temperature. At potentials between 3.0 and 4.8 V, the third $Li^+$ ions from the carbon-coated LVP can be completely extracted, at voltages close to 4.51 V. The carbon-coated LVP exhibits an initial specific discharge capacity of $118mAh\;g^{-1}$ in the voltage region of 3.0 to 4.3 V at a current rate of 0.2 C. The results indicate that the reducing agent and carbon source can affect the crystal structure and electrochemical properties of the cathode materials.

Electrochemical Characteristics of Li3V2(PO4)3 Negative Electrode as a Function of Crystallinity (결정화도에 따른 Li3V2(PO4)3 음극의 전기화학적 특성)

  • Ku, Jun-Whan;Park, Kyung-Jin;Ryu, Ji-Heon;Oh, Seung-Mo
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • $Li_3V_2(PO_4)_3$/carbon composite materials are synthesized from a sucrose-containing precursor. Amorphous $Li_3V_2(PO_4)_3/C$ (a-LVP/C) and crystalline $Li_3V_2(PO_4)_3/C$ (c-LVP/C) are obtained by calcining at $600^{\circ}C$ and $800^{\circ}C$, respectrively, and electrochemical performance as the negative electrode for lithium secondary batteries is compared for two samples. The a-LVP electrode shows much larger reversible capacity than c-LVP, which is ascribed to the spatial $Li^+$ channels and flexible structure of amorphous material. In addition, this electrode shows an excellent rate capability, which can be accounted for by the facilitated $Li^+$ diffusion through the defect sites. The sloping voltage profile is another advantageous feature for easy SOC (state of charge) estimation.

Effects of aprotinin on isolated rat heart in myocardial preservation in prolonged hypothermic cardioplegic followed by reperfusion (아프로티닌이 흰쥐 적출심장의 심근보호에 미치는 영향)

  • 이헌재
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.549-556
    • /
    • 1995
  • We investigated the effects of aprotinin, a protease inhibitor, on isolated rat heart subjected to cardioplegia and global ischemia for 4 hours and then reperfused for 40 minutes. Before ischemia, hearts were perfused with either aprotinin 1x105KIU/L[Aprotinin group,n=8 or no aprotinin[control group,n=8 added to Krebs-Henseleite solution for 30 minutes. Hemodynamic and biochemical parameters such as heart rate, LVP, dP/dt, coronary flow and creatine kinase were measured before cardioplegia and after reperfusion 10,20,30,40 minutes. After completion of experiment, wet and dry heart weight were measured for tissue water and water content evaluation. On reperfusion, recovery of LVP of aprotinin group at each time point was significantly better than that of control group[p<0.05 , and of dP/dt at reperfusion 40 minutes[p=0.034 . No statistically significant differences in heart rate, coronary flow and CK were observed between the two groups, but aprotinin group seemed to have better recovery. No significant differences in tissue water and water content were observed between the two group.These results suggest that pretreatment of aprotinin is effective in myocardial preservation in prolonged hypothermic ischemia and reperfusion.

  • PDF

Protective Effect of Chlorpromazine for the Isolated Rat Heart from Reperfusion Injury (Chlorpromazine 이 과분극 정지심장의 재관류 손상에 미치는 보호효과)

  • 류한영
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 1990
  • This study was designed to investigate the protective effect of chlorpromazine against the reperfusion injury of myocardium after high potassium cardioplegic arrest. Langendorff`s preparations of rat heart were infused with high potassium cardioplegic solution[St. Thomas Hospital Solution] at 25oC. Chlorpromazine [10-7M] increased the recovery of myocardial contractility[dp/dt], left ventricular pressure[LVP], and coronary flow rate of the reperfused heart. Both in control and experimental groups, the restoration of myocardial activity could not reach to the level of preplegic control. These results suggest that the etiologic factors of the reperfusion injury include the influence of high potassium cardioplegic solution and/or reperfusion itself, and that chlorpromazine protects myocardium from the reperfusion injury.

  • PDF

General Pharmacology of KI-60606 (KI-60606의 일반약리작용시험)

  • 김은주;김현진;김동연
    • Biomolecules & Therapeutics
    • /
    • v.10 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • In this study general pharmacological profiles of KI-60606 on the central nervous system, the cardiovascular system and the other organs were investigated. The dosages given were 0,5, 10 and 25 mg/kg and drugs were administered intravenously. The animals used for this study were mice, rats, cats and guinea pigs. KI-60606 showed no effects on general behavior, motor coordination, spontaneous locomotor activity, hexobarbital-induced hypnosis time, body temperature, analgesic activity, anticonvulsant activity and contraction of nictitating membrane in cats. Furthermore KI-60606 showed no effects on blood pressure, heart rate, LVP (left ventricular peak systolic pressure), LVEDP (left ventricular end diastolic pressure), LVDP (left ventricular developing pressure), DP(double product), CFR(coronary flow rate), smooth muscle contraction using guinea pig ileum and gastric secretion at all dosage tested except the increase of gastrointestinal transport and urinary $K^+$ excretion.

Effects of Verapamil in Cardioplegic Perfusates on the Ischemic Myocardium in Isolated Rat Heart (흰쥐의 적출된 심장에서 Verapamil이 허혈성 심근에 미치는 효과)

  • Kim, Su-Cheol;Jo, Gyu-Seok;Park, Ju-Cheol;Yu, Se-Yeong
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.119-124
    • /
    • 1997
  • Using isolated rat heart preparations, we observed the protective effe ts of verapamil cardioplegia on ischemic myocardial injury. Isolated rat hearts were subjected to global ischemia at $25^{\circ}C$ Twenty four isolated Sprague Dawley rat hearts underwent 30 minutes of the retrograde nonworking perfusion with Krebs-Henseleit buffer solution followed by $25^{\circ}C$ cardioplegic solution (St. Thomas'Hospital Cardioplegic Solution) for 60 minutes. Before ischemic arrest, rat hearts were treated with cold cardioplegic solution in control group (n=12) and cold cardioplegic solution with verapamil (1 mg/L) in experimental group (n=12). After 60 minutes of ischemia, hemodynamic and biochemical parameters such as heart rate, left ventricular pressure (LVP), + dp/dt max, coronary flow and creatine phosphokinase (CPK) were measured before giving cardioplegia and 30 minutes after reperfusion. Verapamil group exhibited greater recovery of heart rate, LVP, +dpldt max, coronary flow and CPK than control group (p < 0.05).

  • PDF

Fault Analysis of Semiconductor Device (반도체 장치의 결함해석)

  • Park, S.J.;Choi, S.B.;Oh, C.S.
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.192-197
    • /
    • 2016
  • We have surveyed on technical method of fault analysis of semiconductor device. Fault analysis of semiconductor should first be found the places of fault spots. For this process they are generally used the testers; EB(emission beam tester), EM(emission microscope), OBIRCH(optical beam induced resistance change method) and LVP(laser voltage probing) etc. Therefore we have described about physical interpretation and technical method in using scanning electron microscope, transmission electron microscope, focused ion beam tester and Nano prober.