• Title/Summary/Keyword: LT$_{50}$

Search Result 184, Processing Time 0.023 seconds

Surgical Treatment of Acyanotic Tetralogy of Fallot (비청색성 팔로사징의 외과적 치료)

  • 천종록;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.749-755
    • /
    • 1998
  • Background: Twelve patients with acyanotic tetralogy of Fallot(TOF), characterized by the combination of a malaligned ventricular septal defect(VSD) and infundibular pulmonic stenosis with the clinical finding of acyanosis at rest, underwent surgical correction between January 1988 and July 1997. Materials and methods: 9.92% of patients with the diagnosis of TOF were acyanotic TOF in the same period. Ages ranged from 12 to 42 months(mean 25.2 months). 2D-echocardiographic studies, cardiac catheterization, and angiocardiograms were performed in all patients before operation. The preoperative mean systemic arterial oxygen saturation was 93.5%. According to the 2D-echocardiographic analysis, there was Lt-to-Rt shunt through VSD in 4 patients, bidirectional shunt in 2 patients, and no shunt in 6 patients. Results: The preoperative mean right ventricle to pulmonary artery(RV-PA) pressure gradients were 52.3 mmHg on 2D- echocardiogram and 48.4 mmHg on cardiac catheterization. The repair of ventricular septal defect was performed through a right atrial approach and the hypertrophic infundibular muscle bundles were resected by the transatrial and transpulmonary approach. Six patients(50%) received a transannular patch. The mean cardiopulmonary bypass time was 135.0 minutes, and the aortic crossclamp time was 87.8 minutes. Postoperative complications included bleeding necessitating reentry in one and chylothorax in one. No patient died after operation and there were no late deaths. Postoperative 2D-echocardiograms revealed tiny patch dehiscence in 5 cases and a moderate RV-PA pressure gradients(mean 15.3 mmHg). All patients were in New York Heart Association functional class 1 after operation. Conclusions: acyanotic TOF is the uncommon form of TOF, and acyanotic TOF can be repaired with a good outcome.

  • PDF

Clinicostatistical Analysis for 53 Cases which were performed Microlaryngeal Surgery under Suspension Laryngoscope (Suspension Laryngoscope 하에 후두미세 수술을 시행한 53명에 대한 임상통계학적 고찰)

  • 전하동;최인환;추광철;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.6.3-7
    • /
    • 1979
  • During last two. decades, microlaryngeal surgery opened now era in the laryngeal surgery. In 1960, using Lynch's suspension laryngoscope, Seal co et al performed the first successful microsurgery in the treatment of polyp and other laryngeal diseases. In 1968, Kleinsasser reported a new technique of microlaryngeal surgery with a self retaining laryngoscope. Authors studied the statistic analysis of 53 cases (75 times) of the suspension laryngoscopic microsurgery at E.N.T. department of Han Yang University Hospital from May 1972 to April 1979 an reported this result. 1) sex distribution was male 1.3 : female 1. 2) age distribution was 3rd decade 14 cases (26.4%), 2nd decade 10 cases (18.7%) and 5th decade 9 cases (17%) in order. 3) chief compliant was hoarseness 48 cases (90.6%), dyspnea 16 cases (30.5%) and sore throat 8 cases (15.1%) in order. 4) diagnostic impression was polyp 18 cases (34%), nodule 12 cases (22.6%), papilloma 9 cases (17%), tumor 7 cases (13.2%), intubation granuloma 3 cases (5.7%) in order and other kinds were laryngeal stenosis with decannulation difficulty, laryngeal paralysis and hematoma. 5) histopathologic result of 48 cases was polyp 17 cases (35.4%), papilloma 11 cases (23%), nodule 9 cases (18.9%), malignancy 3 cases (6.3%), chronic inflammation 2 cases (4.2%) in order and others were hyperkeratosis, mucous retension cyst, nodule associated abscess, granuloma, hematoma and unconfirmed case. 6) in involved site, both sides 15 cases (60%), Lt.side 5 cases (19%), Rt side 3 cases (12%), anterior commissure 3 cases (12%) on the nodule and polyp (26 cases) and whole laryngeal involvement 7 cases (63.6%), one side cord involement 3 cases (23.7%), extralaryngeal involvement 1 cases (9.1%) on the papilloma (11 cases).

  • PDF

Evaluation of Puretone Threshold Using Periodic Health Examination Data on Noise-exposed Workers in Korea (소음 특수건강진단 자료를 이용한 순음청력검사 평가)

  • Kim, Yang-Ho;Choi, Jung-Keun;Park, Jung-Sun;Moon, Young-Han;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.30-39
    • /
    • 1999
  • Objectives. This study was carried out to evaluate hearing impairment judgement and to investigate the differences in various diagnostic criteria for noise-induced hearing loss (NIHL) among workers who required for close observation (C). Methods. Out of 731,029 workers who had taken the specific periodic health examination in 1994, we used the audiometric data on 37,999 workers (C) eliminating the employees who had previous otologic problems. Many investigators have being using different criteria for the evaluation of hearing impairment. In this study, we used the criteria of early (1989-1994), current, compensation for NIHL in Korea, 2-, 3-, 4-divided classification and hearing loss at 4,000 Hz and compared the evaluation results. Results. The prevalences of C and workers who had occupational disease $(D_1)$ diagnosed for NIHL were 11.1 % and 0.44 %. There were significant difference in the prevalences of C and $D_1$, depending on different province of Korea. Pure tone averages (PTAs) were not appropriately applied in their evaluation 97% of workers whom we studied on were below the level of mild hearing loss judged by ISO standard. However, there were wide variations in the prevalence rate of mild hearing loss by diagnostic criteria. Thus, there were different judgements in determining the degree of NIHL depending on which diagnostic criteria were utilized. PTAs were found 20.54 (Rt) and 20.74 (Lt) when the method of 3-divided classification was applied for audiometric data. The degree of hearing impairment of the left ear was more severe than that of right ear. The prevalence of normal hearing threshold below 20 dB was 75.4% and the range of difference in both ear was below 10 dB. Right sided hearing threshold levels were 21.08 dB (500 Hz), 18.44 dB (1,000 Hz), 22.09 (2,000 Hz) and 52.36 dB (4,000 Hz). There was typical high frequency loss (C5-dip at 4,000 Hz) above 30 - 40 dB in normal hearing level. The increasing trend in hearing threshold level was gradually decreased by the increase of PTAs. The difference between PTAs and threshold at 4,000 Hz was about 10 dB. Conclusions. We could found that PTAs in the previous examination were not appropriately evaluated. This study revealed that they did not use unique criteria for managing the workers of NIHL. For the prevention of NIHL, it was found that the quality control on diagnosis and comprehensive management program were required, especially for those of hearing loss (C).

  • PDF

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.