• Title/Summary/Keyword: LPG valve

Search Result 74, Processing Time 0.018 seconds

Study for Failure Cases on Engine Electronic Control Computer in Liquid Petroleum Gas vehicle (액화석유가스 자동차 엔진의 전자제어 컴퓨터의 고장사례 연구)

  • Lee, Il-Kwon;Kim, Young-Gyu;Kook, Chang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.28-33
    • /
    • 2011
  • The purpose of this paper analyzes and studies to improve the failure cases on the computer that one of electronic control elements for engine in liquified petroleum gas vehicle. The first case, it certified the non-starting phenomenon of engine that it's electronic control unit didn't control the fuel for idle speed actuator because of no given action signal in slow-cut solenoid valve. The second case, it knew the bad condition phenomenon of engine and back-fire by the wire melting of ignition coil and firing of transistor being inside ECU. The third case, it certified the action stoping phenomenon of engine and malfunctioning signal for engine ECU because of leakage of current and an excess current by moisture inflowing inside ECU curcuit plate. Therefore, it is thought that will elevate the durability and reliability of engine computer throughout procure of quality.

A Development of Forklift Shift and Constant Speed Endurance Test Controller for Dynamometer Test (다이나모 시험용 지게차 변속 및 정속 내구시험 제어기 개발)

  • Jung, G.H.;Lee, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.3
    • /
    • pp.13-21
    • /
    • 2007
  • A forklift is a motive machine powered by LPG, diesel engine or electric motors. The internal combustion engine type forklift is equipped with automatic transmission to meet the required drive load as well as the easy operation of the vehicle. This paper deals with the shift control and endurance test controller which is developed for the functional test of the newly designed automatic transmission on a dynamometer test bench. Its major function is to control the proportional solenoid currents, which is directly related to clutch pressures, for the given reference current trajectory during shift and sequential operation of shift schedule designed for the durability test at each gear. It also has the ability to monitor all the necessary test data through RS232 communication and log them to disk files. The current controller of embedded system is designed from the identified dynamics of solenoid coil and the current reference can be easily modified with a user interface software on PC so as to match the shift data by experiments.

  • PDF

Hydrox Generator for Steel Manufacturing (철강재료 가공용 수산소 혼합가스 발생기)

  • Kim, Hong-Gun;Kwac, Lee-Ku;Lee, Woo-Gum;Cha, Hwa-Dong;Shin, Jooung-Dal
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.257-262
    • /
    • 2011
  • A low capacity generator converted to high capacity of 40m3 is designed and developed in order to use the hydroxy gas in the steel manufacturing process. For efficient design, it is increased from 8 electrode tubes to 10 electrode tubes as well as expanding the diameter of cell integument up to two times bigger, which can increase the amount of hydrogen occurrence per a cell significantly. In addition, circulating pump and pipe, heat exchanger of affiliated SUS material have been used in the circulation of electrolysis catalyst, and circulating cooling section and piping design are also developed. The flame trap is designed into all-in-one suitable check valve in the flow rate of 28-35m3/h and its application is possibly applied in work operation. It is found that the efficiency of generator developed is enhanced substantially up to 84%. It is expected that the application in this field can be expanded significantly by this study.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.