• Title/Summary/Keyword: LPG accident

Search Result 64, Processing Time 0.025 seconds

A Study on the Damage of Flame caused by the Vapor Cloud Explosion in LPG Filling Station (LPG충전소에서 증기운폭발에 의한 화염의 피해에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.53-60
    • /
    • 2010
  • LPG(Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, LPG demand is growing rapidly as an environmentally friendly energy source and its gas station is also increasing every year. Consequently, this study tries to find out the influence of flame caused by the VCE(Vapor Cloud Explosion) in filling station on the adjacent combustibles and people by simulating relevant quantity of TNT. In addition, the damage estimation was conducted by using API regulations. If the scale of the radiation heat is known by calculating the distance of flame influence from the explosion site, the damage from the site can be easily estimated. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analyze, the spot which is 30m away from the flame has 100% of the damage probability by the first-degree burn, 99.2% of the damage probability by the second-degree burn and 93.4% of the death probability by the fire.

The Optimal Design of Explosion Prevention for LPG Storage Tank (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.949-952
    • /
    • 2010
  • The utilization of LPG(Liquefied Petroleum Gas) is increasing as an environmental-friendly fuel in all countries making green growth new paradigm, and use of gas is spread fast as motor fuels to decrease air pollution. Loss of lives by explosion and fire is happening every year as gas use increases, and gas accident in large scale storage property is causing serious problems socially. To minimize this problem, underground containment type storage tank is being presented as an alternative recently. In this study, to minimize explosion occurrence in underground containment type storage tank, the suitable storage tank is designed to consider explosion prevention that makes exposure surface area minimize in confined contents volume and flame to construct storage tank by the most suitable condition in the underground containment room. As a result of the design of storage tank having the most suitable condition by this research, underground containment space was minimized on diameter 3m, length 4.83m in 20 tons storage tank and its safety was improved as exposure surface area in flame decreased by 89.4%, compared with the existent storage tank.

  • PDF

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

An Analysis of Gas Accident between 1995 and 1998, and Suggestion of Accident Reduction Countermeasures. (1995 ${\~}$ 1998년 가스사고 분석 및 사고감소대척 제시)

  • Park Kyo-Shik;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.1-8
    • /
    • 2000
  • It is required that gas accidents should be managed carefully as the consumption of fuel gas increases and high pressure gas process becomes more complex, which may cause a catastrophic accident. Factors to cause accidents were investigated through a systematic analysis of gas accidents between 1995 and 1998, which could be applied to prepare countermeasures to reduce gas accidents. As a result, it was suggested that the effective countermeasures to gas accidents should be kept applied, while new countermeasures were suggested in the field of increasing or not-decreasing number of accident. Totally 2,027 of accidents were reported during this term, and were found to decrease by about $12\%$ every year from 1996. The number of fuel gas such as LPG and city gas accident took up $96\%$, and most of accidents occurred at end-user's facility such as residential house and restaurant business. According to the kind of gas and facility, trend of accident by cause varies, while dominant causes are defective installation, appliance failure, or user's carelessness. Intentional accidents by fuel gas was excluded in this study because of its occurring mechanism and will be analyzed further elsewhere, although it took up $15\%$ and increased by $38\%$ every year.

  • PDF

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Analysis of Safety Decrees for Gas Safety Management System and its Development (주요선진국의 가스기술기준 체제분석 및 제도개선 발전 모형)

  • 김봉진;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.2
    • /
    • pp.51-63
    • /
    • 2001
  • Korea gas industrial because of received LNG in 1987 was converted by the Gas Safety Management System in relation to city gas, LPG and LNG. Gas accident were caused by treatment problem on the supplier and user, on technical and use management mater, on facilities and goods, and included problem with gas safety connection system. This study is present standard application plan of each department to use planning gas technical standard and gas utilization standard of introduction model than statute for change of self-regulation management system and complicated regulation of examination center and order.

  • PDF

A Study on Quantitative Risk Presentation of LNG Station (LNG충전시설의 위험도 표현에 관한 연구)

  • Ko, Jae-Wook;Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Kim, Min-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • There are lots of energy facilities using gas(storage facility, compressed gas pipe, station, tank lorry) on the domestic. These major gas facilities cause major accidents associated with fire, explosion, toxic and etc. With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG (Liquefied Natural Gas) and CNG(Compressed Natural Gas) stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Buchen LPG (Liquefied Petroleum Gas) station, it is difficult to establish a new station. In this research, we present quantitative risk assessment for LCNG;LNG multi-station and compare it result against individual risk criteria of HSE.

  • PDF

Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis (국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구)

  • Ko, Jae-Sun;Park, Sun-Young;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.56-63
    • /
    • 2008
  • We have garnered 3,593 data of gas [Natural Gas (NG) and Liquefied Petroleum Gas (LPG)] accidents reported for 16 years from 1991, and then analyzed the accidents according to their types and causes based on the classified database. According to the results the gas leak has been the most common accident followed by the explosion and then fire accidents. The most frequent accident-occurring locations for fire, explosion and leak are recognized around the valve, hose and pipeline, respectively. In addition, we have applied the Poisson analysis to predict the most-likely probabilities of fire, explosion and release in the upcoming 5 years. From this research we have assured the successive database updating will highly improve the anticipating-probability accuracy and thus it will play a key role as a significant safety-securing guideline against the gas disasters.

  • PDF

Qualitative Hazard Analysis for LNG Gas Stations Using K-PSR Method (K-PSR을 이용한 LNG 충진소에 대한 정성적 위험성평가)

  • Ko, Jae-Wook;Lee, Jae-Min;Yoo, Jin-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.63-69
    • /
    • 2006
  • With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG and CNG stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Bucheon LPG station in 1998, it is difficult to establish a new station. In this research, we conducted qualitative hazard analysis fer LCNG/LNG multi-station by using the K-PSR method and proposed recommendations for hazard mitigation.

  • PDF