• 제목/요약/키워드: LOAD CELL

검색결과 1,188건 처리시간 0.025초

전면 유리와 EVA의 광 반사에 의한 PV모듈의 광전류 손실 예측 시뮬레이션 (A Simulation of Photocurrent Loss by Reflectance of the Front Glass and EVA in the Photovoltaic Module)

  • 이상훈;송희은;강기환;안형근;한득영
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.76-82
    • /
    • 2013
  • The solar cell is a device to convert light energy into electric, which supplies power to the external load when exposed to the incident light. The photocurrent and voltage occurred in the device are significant factors to decide the output power of solar cells. The crystalline silicon solar cell module has photocurrent loss due to light reflections on the glass and EVA(Ethylene Vinyl Acetate). These photocurrent loss would be a hinderance for high-efficiency solar cell module. In this paper, the quantitative analysis for the photocurrent losses in the 300-1200 wavelength region was performed. The simulation method with MATLAB was used to analyze the reflection on a front glass and EVA layer. To investigate the intensity of light that reached solar cells in PV(Photovoltaic) module, the reflectance and transmittance of PV modules was calculated using the Fresnel equations. The simulated photocurrent in each wavelength was compared with the output of real solar cells and the manufactured PV module to evaluate the reliability of simulation. As a result of the simulation, We proved that the optical loss largely occurred in wavelengths between 300 and 400 nm.

수중 환경에서 고분자 전해질 연료전지(PEMFC) 공급용 수소 생산을 위한 가압 디젤 개질시스템에 관한 연구 (Study on Pressurized Diesel Reforming System for Polymer Electrolyte Membrane Fuel Cell in Underwater Environment)

  • 이광호;한광우;배중면
    • 한국군사과학기술학회지
    • /
    • 제20권4호
    • /
    • pp.528-535
    • /
    • 2017
  • Fuel cells have been spotlighted in the world for being highly efficient and environmentally friendly. A hydrogen which is the fuel of fuel cell can be obtained from a number of sources. Hydrogen source for operating the polymer electrolyte membrane fuel cell(PEMFC) in the current underwater environment, such as a submarine and unmanned underwater vehicles are currently from the metal hydride cylinder. However, metal hydride has many limitations for using hydrogen carrier, such as large volume, long charging time, limited storage capacity. To solve these problems, we suggest diesel reformer for hydrogen supply source. Diesel fuel has many advantages, such as high hydrogen storage density, easy to transport and also well-infra structure. However, conventional diesel reforming system for PEMFC requires a large volume and complex CO removal system for lowering the CO level to less than 10 ppm. In addition, because the preferential oxidation(PROX) reaction is the strong exothermic reaction, cooling load is required. By changing this PROX reactor to hydrogen separation membrane, the problem from PROX reactor can be solved. This is because hydrogen separation membranes are small and permeable to pure hydrogen. In this study, we conducted the pressurized diesel reforming and water-gas shift reaction experiment for the hydrogen separation membrane application. Then, the hydrogen permeation experiments were performed using a Pd alloy membrane for the reformate gas.

암모니아 가스 제거를 위한 포괄고정화 담체 개발 (Development of Encapsulated Media for Ammonia Removal)

  • 정미영;남궁형규;송지현;황선진
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.306-310
    • /
    • 2009
  • Packed-bed reactor for removing ammonia was tested at different loading rates. Nitrifiers for ammonia removing was encapsulated in gel media which consisted of polyethlene glycol, alginate and activated carbon. The removal efficiency was nearly 100% when ammonia loading was $12g/m^3/hr$, and the maximum elimination capacity (EC) achieved on this study was $18g/m^3/hr$. The initial microbial portion of nitrifiers in the media was about 82% and it was increased to more than 90% at the end of the operation. Short-term shock loading test was carried out to survey the stability of the media. The inlet loading rates were varied from 2 to $20g/m^3/hr$. The packed-bed reactor overcame the shock loading i.e. removal efficiency recovered rapidly from about 80% to almost 100% within 6 hrs. The results of Live/Dead cell test showed that nitrifiers maintained there activity in the encapsulated media during the test and also against ammonia shock load.

ZVS-PWM Boost Chopper-Fed DC-DC Converter with Load-Side Auxiliary Edge Resonant Snubber and Its Performance Evaluations

  • Ogura, Koki;Chandhaket, Srawouth;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권1호
    • /
    • pp.46-55
    • /
    • 2004
  • This paper presents a high-frequency ZVS-PWM boost chopper-fed DC-DC converter with a single active auxiliary edge resonant snubber in the load-side which can be designed for power conditioners such as solar photovoltaic generation, fuel cell generation, battery and super capacitor energy storages. Its principle operation in steady-state is described in addition to a prototype setup. The experimental results of ZVS-PWM boost chopper-fed DC-DC converter proposed here, are evaluated and verified with a practical design model in terms of its switching voltage and current waveforms, the switching v-i trajectory, the temperature performance of IGBT module, the actual power conversion efficiency and the EMI of radiated and conducted emissions. And then discussed and compared with the hard switching scheme from an experimental point of view. Finally, this paper proposes a practical method to suppress parasitic oscillation due to the active auxiliary resonant switch at ZCS turn off mode transition with the aid of an additional lossless clamping diode loop, and reduced the EMI conducted emission in this paper.

마이크로그리드 과도상태 시 전력 수급 균형 전략 (Power Balancing Strategy in the Microgrid During Transient)

  • 서재진;이학주;정원욱;원동준
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

반복하중을 받는 등방정친압밀점토의 거동 및 한계반복응력 (The Critical Repeated Stress and Behavior of the Isotropic Normally Consolidated Clays Subjected to Repeated Loads.)

  • 김팔규;송전섭
    • 한국지반공학회지:지반
    • /
    • 제4권3호
    • /
    • pp.43-52
    • /
    • 1988
  • 반복하중을 받는 정토의 거동은 단일하중에 의한 결과와 매우 상리하게 나타나며, 그중에서도 특히 간극수려의 거동은 상당히 중요하다. 본 연구는 반복하중 하에서의 점토에 대한 응력-변형 특성을 규명하기 위한 실험적 연구로서 하 중을 가하는 동안에 발생하는 간극수려에 대하여도 언급하였다. 시료는 삼축용기 안에서 24시간동안 등방려밀시켰으며, 삼축시험은 비배수상태 하에서 재성형된 시료에 때하여 압축파괴, 파괴반복, 비파괴 평형시험을 변형제어방법으로 수행하였다. 이에 따라 어느 특정한 시료의 거동을 뚜렷하게 서로 다른 두가지 양상으로 구분하는 반복응력의 한계치가 존재 함을 확인할 수 있었다.

  • PDF

신재생에너지전원을 고려한 새로운 유효설비예비율 평가방법의 개발 (Development of Methodology of New Effective Installed Reserve Rate considering Renewable Energy Generators)

  • 박정제;최재석
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.26-32
    • /
    • 2010
  • This paper proposes a new effective installed reserve rate in order to evaluate reliability of power system considering renewable generators, which include uncertainty of resource supply. It is called EIRR(effective installed reserve rate) in this paper. It is developed with considering capacity credit based on ELCC by using LOLE reliability criterion. While the conventional installed reserve rate index yields over-evaluation reliability of renewable generators, the proposed EIRR describes actual effective installed reserve rate. However, it is not the probabilistic reliability index as like as LOLE or EENS but another deterministic effective reliability index. The proposed EIRR is able to evaluate the realistic contribution to the reliability level for power system considering wind turbine generators and solar cell generators with high uncertainty in resource supply. The case study in model system as like as Jeju power system size presents a possibility that the proposed EIRR can be used practically as a new deterministic reliability index for generation expansion planning or operational planning in future.

전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석 (The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System)

  • 문원식;조성민;신희상;이희태;한운기;추동욱;김재철
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

마이크로 압입 크리프 시험기 개발 및 성능평가 (Development and its Performance Evaluation of a Micro-Impression Creep Machine)

  • 양경탁;김현준;김호경
    • Tribology and Lubricants
    • /
    • 제24권1호
    • /
    • pp.27-33
    • /
    • 2008
  • A micro-impression creep machine was designed and developed, adopting a small punch in diameter of 150 um, displacement gage with an accuracy of sub-${\mu}m$ scale, and load-cell with an accuracy of mN scale in order to investigate creep behavior of small solder ball in diameter of less than 1 mm. Creep behavior of lead-free solder ball(Sn-3.0Ag-0.5Cu) in diameter of $760\;{\mu}m$ was investigated in the stress range of $8{\sim}60\;MPa$ and at $303\;K{\sim}393\;K$. The applied load became decreased slightly and continuously in the creep rate of $10^{-4}/s$ range during the current experiments. Also, the machine frame was so sensitive to the environmental temperature that nm scaled displacement recording was unstable according to the change in environmental temperature.

삼점 신호 평균기법에 의한 요속신호의 잡음 축소 기법 (Noise Reduction Technique by Three-Points Ensemble Averaging in Uroflowmetry)

  • 최성수;이인광;이상봉;박준오;이수옥;차은종;김경아
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1638-1643
    • /
    • 2009
  • Uroflowmetry is a convenient clinical test to screen the benign prostatic hyperplasia(BPH) common in the aged men. A load cell is located beneath the urine container to measure the weight of urine. However, it is sensitive to the impact applied on the bottom of the container by the urine stream, which could be a noise source lowering the reliability of the system. With this aim, our study proposed a noise reduction technique by computing ensemble average of the weighted signals that were acquired from three-load cells forming a regular triangle beneath the urine container. Simulated urination experiment was performed with three different collection methods, all of which demonstrated significant noise reduction by ensemble averaging. Furthermore, the best results can be obtained without any special urine collection devices. Thus, our novel method can be usefully applied to uroflowmetry for enhancing measurement in terms of accuracy and reliability.