• Title/Summary/Keyword: LOA

Search Result 104, Processing Time 0.023 seconds

A Study of Multi Hull Form Design for Small Leisure Fishing Vessels (소형 레저어선의 다동체 선형설계 연구)

  • Lee Seung-Hee;Lee Young-Gill;Kang Dae-Sun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.2
    • /
    • pp.98-108
    • /
    • 2006
  • The vessels, already built and is operating in Korea, have the hull form of catamaran, with LOA(Length Over All) 15 m, LBP(Length Between Perpendiculars) 12 m, GT(Gross Tonnage) 9.77ton, Light Load Displacement 15.1ton. Korean Society of Ship Inspection & Technology, Chungnam National University, Inha University, Seoul National University and Advance Marine Tech co. ltd developed by cooperation it for fishing vessels. And it used FRP(Fiber Reinforced Plastics) for hull material and main engine of diesel $360ps{\times}2800rpm{\times}2sets$ with a water jet system. Based on these results, this paper describe small leisure fishing vessels with multi-hull, in relation to the project of CTYS(Regional Reserch Center for Transportation System of Yellow Sea Inha University) that aimed to development of trimaran hull form(LOA=17m, LBP=14m(Side Hull=6m), GT=9.77ton, Light Weight=11.2 ton).

  • PDF

Stabilization of Soil Moisture and Plant Growth on a Botanical Biofilter with a Wick-Typed Humidifying Apparatus (심지형 가습장치를 이용한 식물바이오필터의 토양수분 및 식물 생육의 안정성)

  • Kim, You Na;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.29 no.5
    • /
    • pp.579-587
    • /
    • 2016
  • The final goal of this research is to develop a miniaturized botanical biofilter using a wick-typed automatic humidifier for stabilizing soil moisture content (SMC) and purifying indoor air pollutants by the biofilter. This new biofilter equipped with wick-typed automatic humidifier was manufactured as more compacted design removing an absorption tower-typed humidifier compared with the previous big-sized biofilter made in 2015. This study was performed to compare changes of SMCs among floors depending on the number of wicks installed on the humidifier within the novel biofilter, and to compare changes of SMCs and plant growth parameters before and after planting Spathiphyllum wallisii ‘Mauna Loa’ on the biofilter. SMCs among floors depending on the number of wicks were similar, and all regression lines of SMCs showed almost horizontal lines because of long-term stability on SMCs. Comparing plant growth parameters of S. wallisii ‘Mauna Loa’ before planting and at 30 days after planting on the biofilter, all growth parameters were not statistically significant. Thus, SMCs of the biofilter were more stabilized using this humidifying apparatus regardless of the number of wicks than the previous biofilter using absorption tower-typed humidifying apparatus.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

Resistance and Seakeeping Tests of a LOA 47.7m Class Catamaran (LOA 47.7m급 쌍동선의 저항 및 내항 시험)

  • H.H. Chun;Y.K. Chung;S.S. Chung;R.H. Chang;S.W. Ha;J.M. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.56-63
    • /
    • 1999
  • The seakeeping and resistance tests of a 47.7m class catamaran are conducted in a towing tank with the 1/21.5 scale model. The effect of the trim tab on the resistance is investigated with the trim tab angle variations and the resistance and trim angle of the catamaran with the trim tab are compared with those without the trim tab. The heave and pitch motions are measured at the three full scale speeds in sea state of 3.4 and 5 and the vertical accelerations at five points on the deck are also measured. The measured accelerations are compared with the criteria of ISO 2631/3 and it is shown that the seakeeping performance of the catamaran is good.

  • PDF

Analysis on Eddy Current Losses for Cylindrical Linear Oscillatory Actuator with Halbach Array according to Drive Voltage Waveform (영구자석 Halbach형 원통형 액추에이터의 구동전압 파형에 따른 와전류 손실)

  • Jang, Seok-Myeong;Kim, Hyun-Kyu;Park, Ji-Hoon;Ko, Kyoung-Jin;Choi, Jang-Young;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.49-51
    • /
    • 2009
  • This paper deals with the analysis on eddy current losses for cylindrical linear oscillatory actuator (LOA) with Halbach array mover according to voltage waveform. This paper presents analytical procedures for calculation of eddy current losses using Poynting theorem. On the basis of the magnetic vector potential and a two-dimensional (2-d) cylindrical coordinate system, this paper derived analytical solutions of eddy current tosses using phase current analysis. The eddy current losses of each harmonic obtained by fast Fourier transform (FFT) analysis of phase current are compared with results obtained from finite-element method (FEM). Particularly, this paper shows that the eddy current losses of cylindrical LOA according to square voltage waveform are more significant than those according to sinusoidal voltage waveform.

  • PDF

The Statistical Identification of Airmass Characteristics during the Manna Loa Observatory Photochemistry Experiment (Mauna Loa (Hawaii)에서 관측된 대기질 특성의 통계적 분석)

  • Lee, Gang-Woong;Barry J. Huebert
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.332-342
    • /
    • 1994
  • Hierarchical cluster and factor analyses were used to identify various influences on free tropospheric air samples at Mauna Loa Observatory in Hawaii during MLOPEX. The cluster analysis separated thirteen chemical and meteorological variables into three characteristic groups (1)clean air, (2)anthropogenically influenced air, (3)marine and volcanic influenced air. The cluster analysis results compared well with those of factor analysis. Six independent components were identified in factor analysis. We have related these components to (1)volcano influenced air, (2)stratosphere-like air, (3)boundary-layer air with recent anthropogenic influence, (4)photochemical haze, (5)marine boundary- layer air, and (6)modified marine tropospheric air. Excluding local influence, we could calculate the nighttime free tropospheric values for $O_3$(41$\pm$10 ppbv), HN $O_3$(94$\pm$45 pptv), N $O_3$$^{[-10]}$ (16$\pm$10 ppbv), S $O_4$$^{[-10]}$ (60$\pm$0 pptv), N $H_4$$^{+}$(71$\pm$6 pptv), N $a^{+}$(5$\pm$1 pptv), PAN(13$\pm$9 pptv), MeN $O_3$(3.5$\pm$1.5 pptv), 2-butyl N $O_3$(0.6$\pm$0.1 pptv), $H_2O$$_2$(1015$\pm$44 pptv), $C_2$C $l_4$(3.3$\pm$0.1 pptv), condensation nuclei(249$\pm$13c $m^{-3}$), and dew point(-8.5$\pm$5.3$^{\circ}C$) during this experiment..

  • PDF

Numerical Additional Study for Evaluate Seakeeping assessment of the Planing Craft (고속활주선의 운동성능 평가를 위한 수치해석적 추가 연구)

  • Kim, Sang-Won;Seo, Kwang-Cheol;Cho, Dea-Hwan;Park, Geun-Hong;Lee, Gyeong-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.236-237
    • /
    • 2017
  • In this research, experimental seakeeping results of Warped hull form 2 on the regular waves were compared with numerical results of strip method and CFD. In case of ship's speed, there are 3 cases (3.4m/s, 4.6m/s, 5.75m/s) for numerical simulation, and they are belong to semi-planing and planing condition. Consequently, in case of strip method, it is shown that the resonance phenomena occurred from around ${\lambda}/L_{OA}=2$ to 4 and RAO value were significantly higher than that of other. this is different from experimental results. In case of CFD, overall trends were similar with experimental values except there are somewhat excessive RAO values around ${\lambda}/L_{OA}=0.5$ to 2.5. these phenomena is confirmed that it became larger as the ship's speed increased, and it was considered that the error occurred because the number of mesh in vertical direction of wave height at ${\lambda}/L_{OA}=0.5$ to 2.5 were relatively less than those of wave height at ${\lambda}/L_{OA}=2.5$ to 5.2.

  • PDF

On the Continuous Monitoring System of CFCs in the Ambient Air (CFCs 자동연속측정시스템 구축)

  • 한진석;강창국;노혜란;이덕희;최양일
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.94-95
    • /
    • 1999
  • 불소나 염소가 수소대신에 치환 되어있는 활로겐화 화합물인 염화불화탄화수소(CFCs chlorofluoro carbons)는 오존층 파괴물질 그리고 지구온난화 기체물질로 널리 알려져있다. 이러한 CFCs는 Mauna Loa, Niwot Ridge, South Pole과 같은 지구배경농도지역에서 70년대 후반부터 지속적으로 측정되어 오고 있다. 대기중 CFCs농도는 일반적으로 수백 ppt 수준으로 매우낮아 측정이 매우 어려운 것으로 알려져왔다.(중략)

  • PDF

Current Control Simulation Research of Moving Coil Type Linear Oscillatory A (가동코일형 LOA 전류제어 시뮬레이션 연구)

  • Jang, S.M.;Kwon, C.;Jeong, S.S.;Lee, S.L.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.614-616
    • /
    • 2001
  • This paper describes the current control simulation of the Linear Oscillatory Actuator and then, the dynamic simulation algorithm considering the armature reaction effect. Thirdly, the control algorithm is proposed to reciprocate a load without mechanical spring at the required stroke and position.

  • PDF

A Fast Response Smectic LCD using Induced Polarization

  • Mochizuki, Akihiro
    • Journal of Information Display
    • /
    • v.6 no.3
    • /
    • pp.6-11
    • /
    • 2005
  • In this paper, a general performance of the PSS-LCD or Polarization Shielded Smectic Liquid Crystal Display is discussed. This smectic base LCD does not use any spontaneous polarization, but uses induced polarization just sa me with current nematic base LCDs. Specific initial molecular alignment as well as specific cell design realizes ext remely fast optical response speed with native wide viewing angle. Moreover, this performance is provided by full compatible electronics for current conventional LCDs. A general performance of the PSS-LCD is introduced herein.