• Title/Summary/Keyword: LNG storage tank structures

Search Result 29, Processing Time 0.022 seconds

The Development of Compressive Strength Estimation Equation for LNG Storage Tank using Rebound Hardness Method (반발경도법을 이용한 LNG 저장탱크 콘크리트의 압축강도 추정식 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.26-32
    • /
    • 2017
  • Outer tank concretes of LNG storage tank are composed of prestressed concrete structures that act as a protective wall. The danger such as the collapse of structures will exist if concrete structures is not secured due to the deterioration. Concrete compressive strength directly related to the safety of structures can be predicted by using estimation equation of compressive strength through rebound hardness test and ultrasonic wave velocity method. But, there is no the estimation equation of LNG storage tank for a relation between NDT data and real strength. In this study, to obtain more accurate real strengths for LNG storage tank, core specimens were sampled from walls of pilot LNG storage tank. The rebound hardness test of general NDT for concrete structures was carried out at each 3 positions for the four areas. The compressive strength estimation equation of LNG storage tank was developed by using the data for rebound hardness test of pilot LNG storage tank and compressive strength test of sampled concrete cores.

Experimental Study of Dynamic Response for Pilot LNG Storage Tank (파이롯트 LNG저장탱크의 동특성 실험연구)

  • Kim, Young-Kyun;Lee, Kang-Won;Hong, Seong-Ho;Kim, Ji-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.591-597
    • /
    • 2003
  • The demand of LNG in Korea has dramatically increased since it was first imported in 1986. Thus, more LNG storage tanks are required to meet the growing consumption of LNG. However the design, construction, and analysis of LNG storage facility need highly advanced technology compared to the general structures due to the fluid-structure interaction and the low temperature of LNG. Recently Korea Gas Corporation(KOGAS) constructed a pilot LNG storage tank, and it is in operation to develop and accumulate the core technology. As a part of those objects, the fundamental dynamic test for the pilot tank were performed. For this study, dynamic test were carried out and the dynamic characteristics of the pilot tank were verified and analyzed.

  • PDF

Dynamic Experiment for Mode Shape of Pilot LNG Storage Tank (Pilot LNG저장탱크의 모드 형상 파악을 위한 동특성 실험)

  • Lee Kangwon;Hong Seongho;Kim Young Kyun;Kim Ji Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.18-23
    • /
    • 2003
  • The demand of LNG in Korea has dramatically increased since it was first imported in 1986. Thus, more LNG storage tanks are required to meet the growing consumption of LNG. However the design, construction, and analysis of LNG storage facility need highly advanced technology compared to the general structures due to the fluid-structure interaction and the low temperature of LNG. Recently Korea Gas Corporation(KOGAS) constructed a pilot LNG storage tank, and it is in operation to develop and accumulate the core technology. As a part of those objects, the fundamental dynamic test for the pilot tank were performed. For this study, dynamic test were carried out and the dynamic characteristics of the pilot tank were verified and analyzed.

  • PDF

FE Analysis on the Strength Safety of a Full Containment LNG Storage Tank System with Damping Safety Structures (댐핑안전 구조물을 고려한 완전밀페식 LNG 저장탱크 시스템의 강도안전성에 관한 유한요소해석)

  • Kim, Chung-Kyun;Kim, Tae-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.85-90
    • /
    • 2007
  • This paper presents the finite element analysis on the strength safety of a full containment LNG storage tank system with damping safety structures. For the FEM analysis of the inner tank, the combined loads in which are related to a hydrostatic pressure, a cryogenic temperature load, BOG pressure, LNG weight, and a sinking force at the comer of the inner tank have been applied to the inner tank structure. The FEM computed results show that the conventional inner tank is safe for the given combined loads, but the damping safety structure such as compressive springs may be more useful structures to increase the safety of the tank system. The increased stiffness and the appropriate position of the springs are very important design parameters for increasing the damping strength safety of the tank system.

  • PDF

A Study on the Strength Safety Analysis of a Full Containment LNG Storage Tank Due to a Wind Pressure (완전밀폐식 LNG 저장탱크에 작용하는 풍압에 의한 강도안전 해석에 관한 연구)

  • Kim, Chung-Kyun;Jeong, Nam-In
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Using the finite element analysis, this paper presents the strength safety of a side wall of an outer tank and a roof structures in a full containment LNG storage tank system. The outer tank structure in which is constructed with a prestressed concrete is forced by internal hydrostatic and hydrodynamic pressures of a leaked LNG and an external wind pressure including a typhoon one. The FEM computed results show that the ring beam between a side wall of an outer tank and a roof structure supports most of the internal and the external loads. This means that the design point of the outer tank system is a ring beam structure and the other one is a center part of the roof structure. In this FE analysis model of a full containment LNG tank system, the outer tank and the roof structures are safe for the given combined loads such as an internal leaked LNG pressure and an external typhoon pressure.

  • PDF

A Study on the Integrated Control and Safety Management System for a LNG Storage Tank (LNG 저장탱크의 통합제어 안전관리 시스템에 관한 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.44-50
    • /
    • 2005
  • This paper presents integrated control and safety management system for a LNG storage tank. This system is for collecting and analyzing the temperature, pressure, and vibration signals in which are used to control and guarantee the system safety and leakage control from the inner gas tank. Based on the investigations of LNG tank related failures and accidents, we strongly recommend the modification and new development of current safety related measuring and control systems because the LNG tank is constructed bigger and bigger in recent years for the efficiency and safety increments. Thus, this paper presents newly developed integrated control and safety management system for a large LNG storage tank. This system provides the enhanced measuring and control systems, and new displacement based safety system, which may detect and control the deformation properties of tank structures. In addition, we recommend that the new integrated control and safety management system should be coupled by process integrated innovation system (PIIS) for an increased safety, efficiency, and productivity of LNG tanks.

  • PDF

A Development of Representative Condition Evaluation Standard for LNG Storage Tank Structures (LNG 저장탱크 구조물의 종합적 상태평가기준 개발)

  • Kim, Jung-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.44-51
    • /
    • 2018
  • As the LNG storage tank is aged, if there is a crack in the outer wall concrete or corrosion of the reinforcing steel, there is a risk of a major accident such as collapse of the structure depending on the type and degree of damage. Since 2014, LNG storage tanks have undergone precise safety diagnosis and safety inspection has been carried out. The condition evaluation criteria for each component have been revised and applied in January 2016. The condition evaluation standard is to evaluate the status of storage tanks based on the appearance survey and material test results of LNG storage tanks and it is important for maintenance. In addition, the representative condition evaluation standard that shows the comprehensive state of each LNG storage tank is important in maintenance, but the related standard for LNG storage tank outer concrete is not available in Korea and abroad, and development of the condition evaluation standard is necessary. In this paper, we examined the structural characteristics of LNG storage tanks, analyzed the status of the condition evaluation criteria for each member, and developed a comprehensive status rating system by weighting the members. We used the AHP(Analytic Hierarchy Process) technique and developed a representative conditon evaluation criteria through surveys of professional organizations.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Estimation for Adaptability of Fiber Reinforced Plastic Composite for LNG Storage Tank (유리섬유강화 플라스틱의 LNG 저장탱크용 합판 대체 가능성 평가)

  • Kim S. B.;Cho J. M.;Cho S. H.;Kwon Y. S.
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.28-32
    • /
    • 2003
  • In order to apply the properties of fiber reinforced plastic(FRP) to support panel of polyurethane foam in LNG storage tank, we estimated the mechanical properties, degree of vapour barrier, chemical stability and thermal conductivity changes as ageing. According to the results, the mechanical strength (i.g. compressive strength, bending strength, tensile strength and shear strength) are more than 30 times higher than those of plywood. The FRP-polyurethane foam(PUF) composites have lower thermal conductivity changes as ageing than plywood-PUF composites. FRP-PUF sandwich composite for LNG storage tank with these remarkable properties are compared the abilities of these structures with those of the conventional structures(plywood-PUF sandwich composite). Finally, we can obtain the effects such as superior mechanical properties and fuel saving through improved ability of vapor barrier.

  • PDF

Structural Analysis for Design of Anchor Straps for a Large-Scale LNG Storage Tank with Corner Protection and Inner Tank (코너프로텍션과 내조를 고려한 대용량 LNG 저장탱크 앵커스트랩의 구조설계를 위한 유한요소해석)

  • Jin, Chengzhu;Ha, Sung-Kyu;Kim, Seong-Jong;Lee, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1543-1548
    • /
    • 2011
  • Structural analysis is performed to design anchor straps for a large-scale-liquefied-natural-gas (LNG) storage tank with corner protection and an inner tank by considering structural integrity. Anchor straps made of 9% nickel steel are attached to the inner tank, corner protection, and concrete raft to prevent the failure of the inner tank during both normal and emergency operating conditions. Two finite element (FE) models were analyzed in this study. One is a stand-alone model of the anchor strap, while the other is an extended model of the substructure of the anchor strap, inner tank, and corner protection. Three-dimensional shell elements are used to effectively assess the bending and axial behavior of structures. The Tresca stress values in each part of the two models are calculated for operation under five different load-condition cases: normal operation, leakage of the LNG, hydro test, and two earthquake conditions.