• 제목/요약/키워드: LINK16

검색결과 535건 처리시간 0.024초

계통선 연결형 인버터 시스템 구성에 관한 연구 (A PWM Controlled High Frequency Link Inverter for Utility Interface Application)

  • 조기연;유동욱;김은수;배진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.466-470
    • /
    • 1991
  • In this paper, full bridge inverter with IGBT is proposed. By Controlling phase angle difference between 2 arms, PWM controlled high frequency link inverter has VVVF capability. For the simplicity, flexibility and compactness of control circuit, 16 bit single chip microcontroller 8797 BH is used and its characteristic is examined through experiment.

  • PDF

역방향 동기식 전송 방법 (Reverse link Synchronous Transmission Scheme)

  • 이동도
    • 정보와 통신
    • /
    • 제16권4호
    • /
    • pp.68-74
    • /
    • 1999
  • 본 논문에서는 최근 IMT-2000을 위한 무선 전송 규격에 반영된 SK 텔레콤의 기술을 설명한다. SK 텔레콤에서는 역방향 다중 접속에 의한 간섭량을 줄이기 위한 기술로서 기지국에서 이동국의 송신 타이밍을 조절하는 '역방향 동기식 전송방식(RSTS : Reverse link Synchronous Transmission Scheme)'을 ITU에 제안하여 현재 W-CDMA의 표준으로 채택되었다. 또한 기지국간 비동기 방식에서 셀 탐색을 위한 방법으로 '클러스터 파일럿과 셀파일럿을 이용한 다단계 셀 탐색 방법'을 제안하여 W-CDMA의 다단게 셀 탐색 방법의 기본 개념을 제시한 바 있다. 본 논문에서는 국제 표준에 반영된이 두가지 방법에 대한 알고리즘을 설명하고 동기식 전송 방식으로 얻게 되는 역방향 다중 접속 간섭량의 감소를 시물레이션을 통해 보인다.

  • PDF

A Study of WiMAX Security threats and Their Solution

  • Woo, Seon-mi;Jeong, Gisung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제8권2호
    • /
    • pp.66-74
    • /
    • 2016
  • In this study, we have discussed and illustrated the security issues of WiMAX technology including vulnerabilities, threats and some security solution. Both physical layer and data link layer have been considered. Jamming is a major threat in physical layer, and in data link layer we study an authentication problem and see the problem of some unencrypted messages leading to lack of confidentiality. Some of these vulnerabilities have been solved in the recent amendment of 802.16 and some still remain. Moreover WiMax is a new technology yet.

Ka 대역 광대역 MMIC 전력증폭기 (PHEMT MMIC Broad-Band Power Amplifier for LMDS)

  • 백경식;김영기;맹성재;이진희;박철순
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.177-180
    • /
    • 1999
  • A two-stage monolithic microwave integrated circuits (MMIC) broad-band power amplifier with AlGaAs/InGaAs/GaAs pseudomorphic high electron mobility transistor (PHEMT) has been developed for the up-link and down-link applications for local multipoint distribution systems (LMDS) in the frequency range of 24~28㎓. The amplifier has a small signal gain of 18.6㏈ at 24.5㎓ and 16.7㏈ at 27.1㎓. It achieved output powers of 19.8㏈m with PAE of 19.8% at 24.5㎓ and 18.8㏈m at 27.1㎓.

  • PDF

다중 전술데이터링크 운용에 따른 데이터 루핑 방지 방안 (A Method For Preventing Data Looping in Multi Tactical Datalink Operation)

  • 우순;임재성
    • 한국군사과학기술학회지
    • /
    • 제16권3호
    • /
    • pp.314-321
    • /
    • 2013
  • In this paper, we have proposed a method which can prevent data looping in multi tactical data-link operating situation. Because the situation of multi tactical data-link in Korea would be more complex than ever before, data looping is more likely to be happened. To prevent data looping, forwarder has to manage TQ(Track Quality) in forwarded track message by degrading it to enlarge correlation gate. Forwarder also has to discard useless track message which can be determined by minimum TQ value. To decide optimal formula for forwarder to degrade TQ and to determine minimum TQ, a research about track motion, correlation, TQ managing, etc in real system is necessary.

A Level Dependent Source Concoction Multilevel Inverter Topology with a Reduced Number of Power Switches

  • Edwin Jose, S.;Titus, S.
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1316-1323
    • /
    • 2016
  • Multilevel inverters (MLIs) have been preferred over conventional two-level inverters due to their inherent properties such as reduced harmonic distortion, lower electromagnetic interference, minimal common mode voltage, ability to synthesize medium/high voltage from low voltage sources, etc. On the other hand, they suffer from an increased number of switching devices, complex gate pulse generation, etc. This paper develops an ingenious symmetrical MLI topology, which consumes lesser component count. The proposed level dependent sources concoction multilevel inverter (LDSCMLI) is basically a multilevel dc link MLI (MLDCMLI), which first synthesizes a stepped dc link voltage using a sources concoction module and then realizes the ac waveform through a conventional H-bridge. Seven level and eleven level versions of the proposed topology are simulated in MATLAB r2010b and prototypes are constructed to validate the performance. The proposed topology requires lesser components compared to recent component reduced MLI topologies and the classical topologies. In addition, it requires fewer carrier signals and gate driver circuits.

A New Technique for Localization Using the Nearest Anchor-Centroid Pair Based on LQI Sphere in WSN

  • Subedi, Sagun;Lee, Sangil
    • Journal of information and communication convergence engineering
    • /
    • 제16권1호
    • /
    • pp.6-11
    • /
    • 2018
  • It is important to find the random estimation points in wireless sensor network. A link quality indicator (LQI) is part of a network management service that is suitable for a ZigBee network and can be used for localization. The current quality of the received signal is referred as LQI. It is a technique to demodulate the received signal by accumulating the magnitude of the error between ideal constellations and the received signal. This proposed model accepts any number of random estimation point in the network and calculated its nearest anchor centroid node pair. Coordinates of the LQI sphere are calculated from the pair and are added iteratively to the initially estimated point. With the help of the LQI and weighted centroid localization, the proposed system finds the position of target node more accurately than the existing system by solving the problems related to higher error in terms of the distance and the deployment of nodes.

Implementation of IEEE 802.11ac Down-link MU-MIMO WLAN MAC using Unified Design Methodology

  • Chung, Chulho;Jung, Yunho;Kim, Jaeseok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.719-727
    • /
    • 2016
  • This paper proposes a unified medium access control (MAC) design methodology and presents the implementation of the IEEE 802.11ac down-link multi-user multi-input and multi-output wireless local area network MAC using the proposed design methodology. The proposed methodology employs unified code for both network simulation and system implementation. Because the unified code closely relates these two processes, the performance of the implemented MAC system can be estimated before implementation. The MAC architecture for an access point implemented using the proposed design methodology is verified on an ARM-based platform, and it is applied to a 65 nm CMOS library.

MIDS LVT 에뮬레이터 연동을 통한 시뮬레이션 환경 구축 (Simulation Environment using MIDS LVT Emulator)

  • 이규현;조규태;이승영
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 추계학술발표대회
    • /
    • pp.380-381
    • /
    • 2016
  • MIDS(Multifunctional Information Distribution System)은 Link16의 작전 운용성을 공중/지상/해상 플랫폼에 확장하기 위해 설계된 전술정보 통신 체계이다. MIDS LVT(Low Volume Terminal)는 제한된 공간, 전력, 공조 시스템 환경에서도 MIDS 운용이 가능하도록 설계가 된 장비로써 본 장비를 탑재한 플랫폼은 Link16 시스템 상에서 통합위치 결정(Intergrated position determination), 운항 및 식별(Navigation and identification), 음성 및 데이터 통신 기능을 수행할 수가 있다. 본 논문에서는 이러한 MIDS에 대한 간략한 소개 및 MIDS LVT 에뮬레이터와의 연동을 통한 시뮬레이션 환경 구축 사례에 대해 다루도록 하겠다.

쿼드콥터 자세 변화에 대응한 착륙 접지면 수평 유지 시스템 (System for Leveling Landing Surface in Response to Changes in Quadcopter Posture)

  • 권영근;천동훈;황성현;최지욱;강호선;이장명
    • 로봇학회논문지
    • /
    • 제16권2호
    • /
    • pp.155-163
    • /
    • 2021
  • In this paper, we propose a four 2-link robotic leg landing system that is used for leveling the bottom of the landing system, even when the quadcopter posture is changed. The case of conventional skid type landing gear has a risk when the quadcopter lands on a moving vehicle because the skid type landing gear is tilted to the landing site at this situation. To solve this problem, it is necessary to level the bottom of the landing system when the quadcopter posture is changed in the flight. Therefore, the proposed landing system used a four 2-link robotic leg with leveling method. The leveling method was derived from the method of determining a plane. The superiority of the proposed system was verified with 6-axis stewart platform and real flight experiment, and it shows feasibility of leveling method and proposed landing system.