• 제목/요약/키워드: LID 기술

검색결과 143건 처리시간 0.025초

경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석 (Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System)

  • 백창열;조천형
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

침투트렌치 시설의 유출저감 효과 분석 (Analysis of Infiltration Trench Facility for Runoff Reduction Effect)

  • 연종상;장영수;신현석;김응석
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5813-5819
    • /
    • 2014
  • 도시화로 인한 도시유역의 불투수면적 증가에 따른 우수유출수 증가를 저감하기 위해 저영향개발의 계획 및 적용이 활발하게 진행되고 있다. 본 연구에서는 LID 요소기술 중 침투트렌치의 국내 적용성 및 성능검증을 위해 침투트렌치 실험조건을 바탕으로 SWMM을 구축하여 유출량 및 비점오염원 저감효과를 분석하였다. SWMM의 침투트렌치 적용면적은 전체 유역면적의 5~15%의 면적에 적용하며 모의를 수행하였다. SWMM 모의결과 첨두유출량은 45.7~61.9%, 총유출량은 47.2~62.3%, BOD 부하량은 52.3~55.3%의 저감효율로 분석되었다. 실험결과와 비교하면 유출량의 경우 12~24% 크며, BOD 부하량의 경우 37~38% 작게 산정되었다. 추후 침투트렌치의 적용성 및 성능검증에 도움을 줄 수 있을 것으로 판단된다.

지능형 물관리를 통한 효율적인 물분배의 탄소저감 효과 분석 (Analysis of carbon reduction effect of efficient water distribution through intelligent water management)

  • 김하룡
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.436-436
    • /
    • 2023
  • 산업혁명을 거치면서 높은 화석연료를 사용하는 제조업 중심의 산업구조와 많은 자원을 필요로 하는 도시의 집중 현상으로 지구 온난화에 따른 이상기후 발생이 증가하고 있다. 이러한 기후변화는 홍수, 태풍, 폭염 및 폭설 등의 자연재해 발생 빈도 및 규모를 증가시켜 피해가 커지고 있다. 특히 인구 및 시설들이 집중해 있어 도시의 집중 현상은 이러한 재해에 더욱 취약한 구조가 됨에 따라 피해의 규모를 가중 시키고 있는 실정이다. 전 세계적으로 기후변화 문제의 심각성을 인식하고 이를 해결하기 위해 선신국에 의무를 부여하는 교토의정서(1997년) 채택에 이어, 선진국과 개도국이 모두 참여하는 파리협정(2015년)을 채택하였고 2016년 협정이 발효되었다. 파리협정의 목표는 산업화 이전 대비 지구 평균온도 상승을 2℃보다 아래로 유지하고, 나아가 1.5℃로 억제하기 노력하는 것을 강제하는 것으로 2050년까지 탄소 순배출량을 '0'으로 만든다는 탄소중립사회로의 전환이 본격적으로 시작되었다. 본 연구에서는 기후변화로 인한 물부족 및 수실오염과 같은 도시의 수자원 문제 해결을 위해 IoT 기반 센서 및 네트워크 기반 수자원 플랫폼을 개발하였다. 도시 수자원 시설 데이터를 기반으로 대체 수자원 확보 및 수요 중심의 물 관리를 통해 효율적인 물 배분이 될 수 있도록 하였으며 이러한 스마트 물 관리에 따른 대체 수자원 확보 및 효율적 물 배분이 탄소 저감에 미치는 효과에 대해 분석하였다. 연구대상 지역은 세종 6-4구역으로 LID 특화지구로 조성되었으며 1,000 세대의 주민이 생활하는 공동주택이다. 물 순환(LID) 시설에서 확보된 물을 물 공급 시설과 연계하여 공동주택에서 활용함으로써 감소된 상수 사용량을 온실가스 배출량으로 환산하여 탄소 저감량을 계산하였다. 실제 주민들(1,000세대)이 사용하고 있는 상수량 데이터와 전력거래소 온실가스 배출계수를 활용하였으며 물순환(LID) 시설로 확보하여 대체할 수 있는 상수량은 10%로 가정하였다. 연구대상 지역(1,000세대)의 연간 상수공급량은 331,603m3이며, 연간 전력사용량은69,637kWh이다. 온실가스 배출량은 31.963tCO2eq이며, 온실가스 저감량은 3.2tCO2eq로 산정되었다. 추후 LID 시설에 대한 상수 대체량과 온실가스 저감효과 정량화가 필요하다.

  • PDF

회전교차로 설계(안) 방안 (Planning of roundabout design)

  • 맹승진;황주하;아잠 무함마드;물타자예브 아르다셔
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.490-490
    • /
    • 2018
  • 우리나라의 홍수대책은 제방 축제 및 보강, 하천의 홍수통수능 확대 등 하천 중심의 대책이 대부분이며, 도시 홍수에 대한 대책과 시설물은 홍수저감용 우수저류조가 대다수이나, 민원과 설치장소 확보 등으로 인해 많은 어려움을 겪고 있다. 또한 가뭄대책은 획일적으로 지하수관정 개발에만 의존하고 있다. 이는 우리의 후손을 위해 보존해야 할 의무가 있으며, 현 세대에서 가뭄을 극복하기 위한 수자원은 강우에 의한 지표수로 해결하려는 노력이 필요하다. 도시의 경우 가뭄 극복을 위해 우수를 저류하여 다양한 용도로 활용하는 기술이 필요하고 사회적으로 많은 관심을 불러일으키고 있다. 국내에 로터리 형태로 운영되던 회전교차로가 교통량 증가에 따라 2000년대 이후 성공적인 해외사례를 토대로 한 간혈적인 도입기를 거쳐 2010년 교통운영체계 선진화 방안에 의한 시범사업 이후 도입이 확대되고 있다. 본 연구에서는 LID(Low Impact Development, 저영향 개발) 기법을 적용하여, 홍수와 가뭄에 대한 대책으로 회전교차로 중앙교통섬을 활용한 초기 우수대응 기술을 개발하고 이를 실현할 수 있는 효과적인 회전교차로 설계 및 시공기술을 개발하고자 한다. 도시의 경우 강우시 초기강우에 의한 유출수에는 인체에 해로운 오염물질들이 포화되어 있기 때문에 초기우수에 의한 유출수를 효과적으로 배제하여 하천수질 등 개선하고자 하며, 이와 같은 초기우수에 대한 비점오염원 저감 시설과 우수를 집적하는 우수저류시설을 회전교차로 내에 설치하고 초기 우수에 대한 관리 기법을 개발하고자 한다.

  • PDF

중·대형 디스플레이용 건식 식각(ICP Dry etcher) 설비의 플라스마 균일도 제어 기술 (Plasma Uniformity Control Technology for Dry Etching (ICP Dry etcher) Equipment for Medium and Large Displays)

  • 홍성재;전홍구;양호식
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.125-129
    • /
    • 2022
  • The current display technology tends to be highly integrated with high resolution, the element size is gradually downsized, and the structure becomes complicated. Inductively coupled plasma (ICP) dry etcher of various types of etching equipment is a structure that places a large multi-divisional antenna source on the top lid, passes current to the Antenna, and generates plasma using the induced magnetic field generated at this time. However, in the case of a device of a large area size, a support that can withstand a load structurally is necessary, and when these support portions are applied, arrangement of antenna becomes difficult, which causes reduction in uniformity. As described above, the development of antenna source of a large area having a uniform plasma density on the whole surface is difficult to restrict hardware (H/W). As a solution to this problem, we confirmed the change in uniformity of plasma by applying two kinds of specific shape faraday shield(FICP) to the lower part of the large area upper lid antenna of 6 and 8th more than that generation size. In this thesis, we verify the faraday shield effect which can improve plasma uniformity control of ICP dry etcher equipment applied to medium and large displays.

도시 및 도로 조경공간을 활용한 소규모 인공습지 조성 기술 (Development of small constructed wetland for urban and roadside areas)

  • 강창국;;손영규;조혜진;김이형
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.231-242
    • /
    • 2011
  • 도시화가 진행될수록 건물의 옥상 및 교통관련 시설물 또한 증가하여, 녹지공간은 감소하고 불투수면은 증가하게 된다. 불투수면이 증가함에 따라, 도시내 자연적 물순환 시스템 파괴, 비점오염물질 증가, 생태축 단절 등과 같은 다양한 환경수리학적 문제점이 발생되고 있다. 최근 들어 국민들의 생활 및 의식수준이 향상되면서, 도시의 경제적인 측면뿐만 아니라 심미적인 측면, 환경적인 측면을 동시에 고려한 지속가능한 도시 개발이 요구되고 있다. 또한 강우유출수 관리에 대한 관심과 인식이 높아지면서 Low Impact Development(LID) 관련 기술의 개발 및 적용에 관한 연구가 활발히 진행되고 있으나, 국내 환경에 적합한 가이드라인, 설계기준 등은 매우 부족한 실정이다. 본 연구는 도시 및 도로가에 적용하기 위한 소규모 인공습지 기술을 개발하기 위하여, Pilot-scale 실험을 실시하였으며, 분석 결과, TSS, $COD_{Cr}$, TN, TP, Total Pb에 대한 평균저감효율이 각각 95%, 82%, 35%, 91%, 57%로 나타났다. 이러한 결과는 소규모 인공습지가 향후 도시 내 효율적인 물순환 시스템을 구축하고, 수생태계 보전에 기여할 수 있을 것으로 판단된다.

국내 비점오염 관련 연구 동향 및 향후 연구방향 제언 (A Review of Research Trend Related to NPS and Suggestion for Research Direction in the Future)

  • 전제찬;정제호;김용석;김이형
    • 한국습지학회지
    • /
    • 제20권1호
    • /
    • pp.80-93
    • /
    • 2018
  • 본 연구에서는 1980년대부터 수행되어온 비점오염원과 관련된 연구동향을 1) 비점오염물질의 유출특성, 2) 처리기술, 3) LID 및 GI 기술, 4) 관리방안 및 정책의 4개 분야로 나누어 검토하고, 향후 연구방향을 제시하였다. 비점오염원과 관련된 연구는 2010년 이전까지는 주로 비점오염물질의 유출특성에 관한 연구가 주를 이루었으며, 최근에는 LID 및 GI 기술 개발 효과평가 및 적용이 주를 이루고 있었다. 비점오염원의 대책마련을 위해서는 사회 지리 환경 기상 등 많은 분야를 접목한 연구가 이루어져야 하지만 아직까지는 많이 미흡한 실정이었다. 또한, 지역적으로 비점오염의 발생 원인물질과 최적 저감대책이 다를 수밖에 없으므로 중앙정부에 의한 일률적인 대책과 가이드라인보다는 지역의 특성을 고려한 대책과 가이드라인의 마련이 필요하였다. 아울러 관주도가 아니라 민간주도로 비점오염원을 관리할 수 있는 법과 제도의 마련이 필요하였다. 아울러 관주도가 아니라 민간주도로 비점오염원을 관리할 수 있는 법과 제도의 마련을 위한 연구가 수행되어야 할 것이다.

소규모 개발사업의 저영향개발(LID) 사전협의 제도 도입 연구 - 비용편익 분석을 중심으로 - (A Study on The Introduction of LID Prior Consultation for Small-Scale Development Projects - Focusing on Cost-Benefit Analysis -)

  • 지민규;사공희;주용준
    • 청정기술
    • /
    • 제26권2호
    • /
    • pp.151-157
    • /
    • 2020
  • 급격한 도시화는 국토의 불투수면을 증가시켜 도시형 홍수의 위험성을 가중시켜왔고, 지하수위의 저하, 수질오염물질 증가 등 환경재해 및 환경오염 문제를 유발시키고 있다. 국내에서는 이러한 환경적 영향을 최소화하고 개발 이전의 물순환 건전성을 유지하기 위해 저영향개발 기법을 도입하여 적용하고 있지만, 소규모 개발사업의 대부분은 강우유출량 관리의 법적 근거가 부재하여 사각지대에 놓여 있다. 이에 빗물의 표면 유출을 증가시키는 소규모 개발사업 또한 오염원인자 책임 원칙에 따라 저영향개발 시설의 적용을 의무화하는 것이 요구되며 이를 위해 물순환 회복 사전협의 제도를 도입하는 것이 필요하다. 본 연구는 소규모 개발사업의 저영향개발기법 도입을 가정하여 비용편익 분석을 중심으로 수행되었다. 비용·편익 분석에 필요한 전국 소규모 개발 대상사업의 규모 및 건수는 『건축법』에 따른 대지면적이 1,000 ㎡ 이상 이거나 건축연면적 1,500 ㎡ 이상의 건축물에 서울시의 실제 사전협의 통계자료를 적용하여 도출하였다. 피규제 기업·소상공인, 피규제 이외 기업·소상공인·일반국민 및 정부를 대상으로 소규모 개발사업의 저영향개발 시설물 설치에 따른 비용·편익을 분석한 결과, 경제성의 기준 값인 1보다 많이 낮은 것으로 확인되었으며 이는 대상사업의 규모 대비 시설물의 설치 비용이 높기 때문으로 사료된다. 하지만 저영향개발 시설의 설치에 따른 수환경 및 대기질 개선 등의 환경적 가치와 하수처리시설 운영비 절감 등의 공공성을 고려하면 향후 소규모 개발사업의 사전협의제도 도입은 필연적이다. 앞으로 소규모 개발사업의 사전협의 제도 도입과 함께 비용·편익을 개선하기 위해서는 지자체의 제도적, 재정적 지원이 적극적으로 요구된다.