• Title/Summary/Keyword: LED Fluorescent Lamp

Search Result 124, Processing Time 0.03 seconds

Development of The LED FDL for Replacing Fluorescent Lamp (형광램프대체용 LED FDL 개발)

  • Yang, Byong-Moon;Jang, Woojin;Cha, Jae-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

A Study on LED Fluorescent Lamp applying Circuit Driven Method to Tubular LED Lamp Converter (직관형 LED램프 컨버터에 회로구동방식을 적용한 LED 형광등 연구)

  • Yang, Byongmoon;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2015
  • In this paper, we perform a study on LED Fluorescent Lamp applying Circuit Driven Method to Tubular LED Lamp Converter. The energy efficiency of LED fluorescent lamp converter requires exceptional protection circuit design, circuit design and structure, because it can not take advantage of Heat-sink structure of the heightened degree Reflector for Fluorescent Lamp. In this paper, we performed a study on LED fluorescent lamp applying circuit driven method to tubular LED lamp converter, Also, we designs LED lamp and converter which can supply DC power common commercial power source.

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

Interior Light Environment and Building Energy Performance Analysis of LED and Fluorescent lamp installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.466-471
    • /
    • 2009
  • Generally LED lamp has many advantages to compare with a general lamp, long life and no pollution matter like the mercury. Also it is excellence for color rendering and need to small consumption electric rower. However LED lamp has some disadvantages to compare to general fluorescent lamp and That is small light flux about 50% and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, after analyze a illuminance distribution with an environment analysis and cooling, heating and light energy. The purpose of this study is to analyze light environment. light, cooling and heating energy simulation in Office building.

  • PDF

A Study on the Application of LED Light Source in Subway Train (도시철도차량에 LED 광원의 적용에 관한 연구)

  • Choi, Sung-Kuk;Park, Dae-Won;Kil, Gyung-Suk;Park, Hee-Chul;Jo, Eun-Je
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.2050-2055
    • /
    • 2009
  • This paper describes the proceeding experimental results to replace the 32 [W] fluorescent lamp installed in subway train to a LED module. We fabricated 25 [W] LED modules to meet the illuminance 300 [lx] specified in the standard for subway train. After the installation of LED modules, comparative analysis with conventional fluorescent lamps was carried out. From the experimental results, illuminances on the height of 0.85 [m] and 1 [m] above floor were 323 [lx] and 360 [lx], respectively. These illuminances satisfied the requirement 300 [lx]. By the application of 25 [W] LED module as a light source in subway train, energy saving about 22 [%] compared with 32 [W] fluorescent is acquired. Also, low cost of maintenance is expected due to 8 times longer lifetime 50,000 hours of LED than that 6,000 hours of fluorescent lamp.

  • PDF

Effect of night break treatment using Red LED (660 nm) on flower bud initiation and growth characteristics of chrysanthemum cv. 'Baekma', and cv. 'Jinba' (적색 LED(660nm)의 광중단 처리에 따른 국화 '백마'와 '신마'의 화아분화 및 생육특성)

  • Kwon, Young Soon;Choi, Seong Youl;Kil, Mi Jung;You, Bong Sik;Jung, Jae A;Park, Sang Kun
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.297-303
    • /
    • 2013
  • This study was carried out to examine the effect of Red LED (660 nm) and fluorescent lamp for night break (NB) treatments of each 3 hours (22:30-01:30), 4 hours (22:00-02:00) and 5 hours (21:30-:02:30) per day for 53 days on flower bud initiation and growth in Chrysanthemum cv. 'Baekma' and cv. 'Jinba'. The days to flower budding after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (21.0 days) and 5 hr (20.5 days) NB, and it was shorter at Red LED 3 hr (14.2 days). The days to flowering after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (54.0 days), 5 hr (53.5 days) NB, and Red LED 5 hr (53.3 days), and it was shortest at Red LED 3 hr (50.2 days) NB treatment among all treatments. The days to flower budding after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (20.6 days) and was shorter at Red LED 3 hr (14.1 days) among all treatments. Similarly, the days to flowering after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (55.3 days) and was shortest at Red LED 3 hr (50.2 days) among all treatments. Therefore, inhibition of flower bud initiation was the most effective under fluorescent lamp 4 hr treatment. The length of cut flower of 'Baekma' was increased by fluorescent lamp 4 hr, 5 hr, and Red LED 5 hr, but of 'Jinba' was longer at LED 4 hr and 5 hr treatment. The weight of cut flower of 'Baekma' was heaviest at fluorescent lamp 5 hr treatment and was at Red LED 5hr treatment for 'Jinba' even though there was not statistically significant difference between 'Baekma' and 'Jinba'. Consequently, under fluorescent lamp 4 hr for night break was the most effective on flower bud initiation, flowering inhibition and cut-flower characteristics in 'Baekma' and 'Jinba'.

Analysis on the Light Source Efficiency of CCFL and LED Monitors (CCFL 및 LED 모니터 광원 효율 분석)

  • Shin, Hee-Woo;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.44-50
    • /
    • 2021
  • In this paper, we analyze the efficiency of light sources of CCFL and LED monitors. Cold Cathode Fluorescent Lamp (CCFL), which is widely used as a light source for LCD display, supplies a high voltage of 1,200[V] or more when it is initially driven. In addition, a constant normal voltage of 400 ~ 800[V] after lighting, and 3 ~ 6[ mA] is needed for a power circuit that can stabilize the current. Applying a high voltage causes a lot of stress on the inverter and generates a lot of heat in the cold cathode lamp, causing significant damage to the BLU (Back Light Unit), resulting in a burning phenomenon, which causes the screen to output normal colors when outputting the screen. We can not see the yellow output and the screen darkened. Therefore, in order to prevent such a symptom in advance, efficiency can be increased by using a Light Emitting Diode (LED) as the light source of the LCD display instead of a cold cathode fluorescent lamp (CCFL). As a result, it is shown that the LED method outperforms the CCFL method.

Interior Light Environment and Building Energy Performance Analysis of LED Lamp Installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-85
    • /
    • 2010
  • In this paper, A new integrated energy simulation results of LED lamp are presented to use it effectively in the office buildings. Generally LED lamp has many advantages in comparison with a general lamp such as long life and no pollution problem like the mercury. It also is excellent in color rendering and small consumption electric power. However LED lamp has some disadvantages to compare to general fluorescent lamp. It is small light flux about 50[%] and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, the illuminance distribution with an environment analysis and cooling, heating and light energy has to be analyzed. The purpose of this study is to analyze light environment, light, cooling and heating energy simulation in office building.

A Study on the Comparison of the Emotional Experiment from Fluorescent Lamp and LED Lighting (사무공간의 사용자 행위별 형광램프와 LED조명 감성비교 실험에 관한 연구)

  • Lee, Min-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.8-17
    • /
    • 2012
  • Unlike traditional lightings, LED lighting is one of objects that sends user an emotional segments through brightness control from various color temperature and dimming control. Also, within present interior lighting environment, emotional researches about traditional fluorescent lamp and newly implemented LED lighting environment are in active progress. Despite the fact adjectives describing emotions and scale modeling have been repeatedly used in many cases for a long time, there seems to be a lack of results in reliability, and there is a limitation for applying into actual lighting design. The purpose of this study is to construct an actual sized test-bed, which is used to draw out one's emotional words of behavior patterns from inner emotional experiences about lighting environment in an office space. Also, having fluorescent lamp and LED lighting as the main test subjects, we have tested emotional parts according to the changes of color temperature and adjective vocabularies chosen from user's action, and we have compared and analyzed the drawn out data. Also, having fluorescent lamp and LED lighting as the main test subjects, we have tested emotional parts according to the changes of color temperature and adjective vocabularies chosen from user's action, and we have compared and analyzed the drawn out data.

A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.