• Title/Summary/Keyword: LCP

Search Result 148, Processing Time 0.024 seconds

Microstructural Morphology of Molded Thin Composites of Thermotropic Liquid Crystalline Polymer and Polyamide 6 (서모트로픽 액정폴리머와 폴리아미드6으로 성형된 얇은 복합재료의 미세구조형태)

  • Choe, Nak-Sam;Choe, Gi-Yeong;Ha, Seong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1703-1711
    • /
    • 2000
  • Microstructural morphology of molded composites of thermotropic liquid crystalline polymer(LCP) and polyamide 6 (PA6) has been studied as a function of epoxy fraction. Injection-moulding of a thin composite plaque at a temperature below the melting point of the LCP fibrils by suing the extruded LCP/PA6 pellets produced multi-layered structures: 1) the surface skin layer with thickness of 65-120 ym exhibiting a transverse orientation, 2) the sub-skin layer with an orientation perpendicular to the surface skin, i.e. in the flow direction, 3) the core layer with arc-curved flow patterns. Similar microstructural orientations were observed in the respective layers for the composite plaques with different fractions of epoxy.

Investigation on Hermeticity of Liquid Crystal Polymer Package for MEMS Based Safety Device (MEMS 기반 안전 소자에 대한 액정 폴리머 패키지의 밀폐도 연구)

  • Choi, Jinnil;Kim, Yong-Kook;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.287-290
    • /
    • 2015
  • Liquid crystal polymer (LCP) is a thermoplastic polymer with superior mechanical and thermal properties. In addition, its characteristics include very low water absorption rate and possibility to apply bonding process under low temperature. In this study, LCP is utilized as a packaging material for a microelectronic system (MEMS) based safety device with suggestion of a low temperature packaging process. Highly sensitive and stable capacitive type humidity sensor is fabricated to investigate hermeticity of the packaged MEMS device.

Establishment and Application of Landscape Control Point Selection Method for Landscape Assessment of Urban Development Projects (도시개발사업의 경관평가를 위한 조망점 선정체계 구축 및 적용)

  • Jang, Cheol-Kyu;Jung, Sung-Gwan;Kim, Kyung-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.39-50
    • /
    • 2011
  • This study furnishes basis data for plan foundation and proper valuation of view by presenting objective and concrete selection standards and ways of Landscape Control Point(LCP) on valuation of development projects. To sum up the results of study, it establishes the prospect, publicity and direction of view as a selection standard LCP on precedent studies. The prospect, which includes visual range, direction of view, geographical features, and visibility, sets up as a valuation basis picking out the available places which have alterations according to direction and distance in practice. In the case of publicity, to select the place as there presentative area where public activities often happen than others, thirteen evaluation indexes including administration facilities, educational facilities, commercial facilities and so on. And variation of landscape is set up as an assessment index to know how much the land has changed from the beginning to the end of development. To apply the selection standards to sample places, the preliminary LCP is founded by analyzing both the prospect and published; a series of courses for selecting the final LCP is founded by analyzing the preliminary LCP and variableness of landscape on a basic of placed which have many alterations of view. At last, in the case of a selection system for LCP, the preliminary LCP is founded by analyzing both the prospect and publicity; a series of courses for selecting the final LCP is found by analyzing the preliminary LCP and variableness of landscape. Applying selection standards and the assessment index to the Sam-deok 3 residence improvement area, in the case of prospect, the southern distant view area has the largest extent. Next, the results of the assessment using the system of publicity show that a five-lane road is taking up the largest area. Hence, a total of 48 preliminary LCPs are set up by analyzing both the prospect and publicity. The results of analyzing landscape variation, one of the valuation indexes, show that Sam-deok dong around the post office has the highest rate of variation at 28.07%. Finally, three LCPs in each part, which are close range, middle range and distance view, are selected; thus, a total of nine LCPs are selected. The selected LCPs that go through a series of practical courses like a GIS program have a lot of professional opinions and are expected to secure objectivity of landscape assessment.

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Efficient Storing of Suffix Arrays using Block-Sorting Compression (블록정렬압축을 이용한 접미사배열의 효율적인 저장)

  • Lee, Geon-Ho;Park, Geun-Su
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.7
    • /
    • pp.350-355
    • /
    • 2001
  • 블록정렬압축은 빠른 속도로 동작하면서 높은 압축률을 나타내는 압축 방법이다. 또한 블록정렬방식으로 압축된 텍스트는 원래 텍스트를 복원하는 과정에서 접미사배열을 0(n) 시간만에 구할 수 있다. 그러나 접미사배열을 이용하여 효율적인 검색을 수행하려면 lcp(longest common prefix)정보가 추가적으로 필요하다. 본 논문에서는 텍스트와 접미사배열이 주어졌을 때 lcp정보를 0(n) 시간만에 구할 수 있는 알고리즘을 제시한다.

  • PDF

Efficient storing of suffix arrays using block-sorting compression (블록정렬압축을 이용한 접미사배열의 효율적인 저장)

  • 이건호;박근수
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10a
    • /
    • pp.554-556
    • /
    • 2000
  • 블록정렬압축은 빠른 속도로 동작하면서 높은 압축률을 나타내는 압축 방법이다. 또한 블록정렬방식으로 압축된 텍스트는 원래 텍스트를 복원하는 과정에서 접미사배열을 O(n) 시간만에 구할 수 있다. 그러나 접미사배열을 이용하여 효율적인 검색을 수행하려면 lcp(longest common prefix)정보가 추가적으로 필요하다. 본 논문에서는 텍스트와 접미사배열이 주어졌을 때 lcp정보를 O(n)시간만에 구할 수 있는 알고리즘을 제시한다.

  • PDF

Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture (경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과)

  • Chung, Hyung-Jin;Choo, Ji Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.