• Title/Summary/Keyword: LC20

Search Result 644, Processing Time 0.028 seconds

Simultaneous determination of seven major human cytochrome P450 activities using LC/MS/MS

  • Lee, Seung-Seok;Kim, Hae-Kyoung;Jin, Joon-Ki;Lee, Hye-Won;Kim, John;Lee, Hye-Suk
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.404.1-404.1
    • /
    • 2002
  • A LC/MS/MS method for the simultaneous determination of the activities of seven major human drug-metabolizing cytochrome P450s (CYP3A4. CYP2D6. CYP2C9. CYP1A2, CYP2C19, CYP2A6. and CYP2C8) was developed. This method used an in vitro cocktail of specific substrates (midazolam. bufuralol. diclofenac, ethoxyresorufin. S-mephenYlOin. coumarin. and paclitaxel) and LC/MS/MS. The assay incubation time is 20 min and the analysis time is 8 min/sample. (omitted)

  • PDF

Median Lethal Concentration ($LC_{50}$) for 24 Hours of Formalin to Eel, Anguilla japonica (뱀장어에 대한 포르말린의 24시간 반수치사농도 ($LC_{50}$))

  • Jung, Sung-Hee;Lee, Joo-Seok;Jee, Bo-Young;Seo, Jung-Soo;Kim, Jin-Woo;Kim, Eung-Oh
    • Journal of fish pathology
    • /
    • v.20 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • Acute toxicity of formalin (37% formaldehyde) was conducted to determine the median lethal concentration (LC50) on eel (avarage weight 96 ± 3.6 g, average total length 43 cm), Anguilla japonica at concentrations ranging from 0 to 500 ppm. In particular, this study was designed to estimate the safety concentrations of formalin in testing eels to eradicate Pseudodactylogyrus. All fish died after 10 hours and 24 hours at 500 ppm and 400 ppm, respectively. After 24 hours, cumulative mortality was 96.6% and 13.3% at 300 ppm and 200 ppm formalin, respectively. However, all experimental fish were alive after 24 hours at 100 ppm. The lethal concentration values were computed by using non-linear least square method. At the start of the test, water temperature, pH and dissolved oxygen level were 27~28℃, 7.4 and 5.55 ppm, respectively. The 24 hr-LC50 were 269 ppm.

Comparison of the efficacy of erector spinae plane block according to the difference in bupivacaine concentrations for analgesia after laparoscopic cholecystectomy: a retrospective study

  • Yoo Jung Park;Sujung Chu;Eunju Yu;Jin Deok Joo
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.172-178
    • /
    • 2023
  • Background: Laparoscopic cholecystectomy (LC) is a noninvasive surgery, but postoperative pain is a major problem. Studies have indicated that erector spinae plane block (ESPB) has an analgesic effect after LC. We aimed to compare the efficacy of different ESPB anesthetic concentrations in pain control in patients with LC. Methods: This retrospective study included patients aged 20 to 75 years scheduled for LC with the American Society of Anesthesiologists physical status classification I or II. ESPB was administered using 0.375% bupivacaine in group 1 and 0.25% in group 2. Both groups received general anesthesia. Postoperative tramadol consumption and pain scores were compared and intraoperative and postoperative fentanyl requirements in the postanesthesia care unit (PACU) were measured. Results: Eighty-five patients were included in this analysis. Tramadol consumption in the first 12 hours, second 12 hours, and total 24 hours was similar between groups (p>0.05). The differences between postoperative numeric rating scale (NRS) scores at rest did not differ significantly. The postoperative NRS scores upon bodily movement were not statistically different between the two groups, except at 12 hours. The mean intraoperative and postoperative fentanyl requirements in the PACU were similar. The difference in the requirement for rescue analgesics was not statistically significant (p=0.788). Conclusion: Ultrasound-guided ESPB performed with different bupivacaine concentrations was effective in both groups for LC analgesia, with similar opioid consumption. A lower concentration of local anesthetic can be helpful for the safety of regional anesthesia and is recommended for the analgesic effect of ESPB in LC.

Analysis of Amadori Compounds in Tobacco Leaf by LC-MS/MS (LC-MS/MS를 이용한 담배 중 Amadori Compounds의 분석)

  • Min, Hye-Jeong;Kim, Young-Hoi;Lee, Jeong-Min;Jang, Gi-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.33 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • Amadori compounds(1-deoxy-1-amino-2-ketoses) are important precursors of color, flavor and aroma produced in foods. Amadori compounds occur naturally in tobacco. The contribution of amadori compounds to smoke quality has been (of) interest because of their roles of the Maillard reaction in the leaf chemistry. The amounts of these compound in tobacco are affected by the processes of aging, drying and storage conditions. In this study, eight compounds were chemically synthesized because amadori compounds (have not been sold commercially these days.) were not available for obtaining commercially. The aim of this study was to develop the analytical method of amadori compounds in tobacco leaf by the liquid chromatography mass spectrometry using triple quadrupole analyzer(LC-MS/MS). This method was simple, rapid, selective and sensitive, and eight amadori compounds were simultaneously and quantitatively analyzed within 20 minutes. This method showed excellent accuracy and precision. Recovery rates of amadori compounds ranged from 86% to 102%, with relative standard deviation(RSD) ranged from 2.6% to 5.9%. This method was applied to analysis of amadori compounds contents of tobacco leaves in different varieties. Furthermore, it was expected that the method could be extended to the analysis of other amadori compounds.

Electro-optical Properties of PVC/Nematic Liquid Crytal Composite Films (PVC/Nematic 액정복합막의 전기광학특성)

  • Lee, Jong-Cheol;Kim, Byeong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.388-394
    • /
    • 1993
  • The state of aggregation and optical contrast of poly(vinyl chlorich, )(PVC)!nematic liquid crystal(LC) composite film liave been studied for a wide range(30~70 wt% LC)of film composition. In addition. effects of temperature, frequency and voltage of the applied AV electric field on the film transmittance have heen measured for a film containing (6O wt % I, C, which showed maximum optical contrast. For this particular composition of film, tlw thn'shold voltage was smalkr than .40$V_{p-p}$ at I kHZ, $25^{\circ}C$, and the rise time and decay time were smalle, r than l0Oms at 100$V_{p-p}$, I kHz, and $25^{\circ}C$.

  • PDF

Delayed Mortality of Benthic Amphipods Monocorophium acherusicum Exposed to Various Pollutants in Seawater(Cd, Cu, Hg, TBT, Ammonia and Phenanthrene) (유해오염물질에 급성 노출된 단각류 Monocorophium acherusicum의 지연 사망률에 관한 연구)

  • Lee Jung-Suk;Lee Kyu-Tae
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.2 s.49
    • /
    • pp.133-141
    • /
    • 2005
  • 다양한 유해오염물질에 급성 노출된 단각류 Monocorphium acherusicum의 노출 기간 이후에 발생하는 지연 사망(latent mortality)이 반수치사농도(LC5O)산출에 어떤 영향을 미치는 지를 규명하기 위한 일련의 실험이 수행되었다. 본 연구에서는 실험생물을 카드뮴, 구리, 수은과 같은 중금속, tributyltin(TBT), 암모니아 그리고 방향성탄화수소인 phenanthrene에 각각 96시간 동안 노출시킨 후 깨끗한 해수에 옮겨 다시 6일 동안 배양하면서 사망률을 조사하였다. 실험결과 구리, TBT, 암모니아, phenanthrene과 같은 물질에 노출된 M. acherusicum의 사망률은 노출이 끝난 이후에도 계속적으로 증가하는 지연 사망이 관찰되었으며, 이에 따라 기존의 방법_으로 산출된 96-h LC50보다 지연 사망을 고려한 새로운 LC50이 크게 낮아지는 경향이 관찰되었다. 지연사망률을 고려하지 않은 기존의 독성시험 결과는 지연 사망의 영향을 반영하지 못하므로 실제 현장에서 발생할 수 있는 오염물질의 영향을 과소평가 할 가능성이 있다. 따라서 지연 사망률에 대한 고려는 실제 현장 개체군에 대한 유해오염물질의 영향을 보다 정화하게 예측하는 데에 활용될 수 있을 것이다.

Control of pretilt angles on $SiO_x$ Thin Film by Electron Beam Evaporation Method (전자빔 경사증착을 이용한 $SiO_x$ 박막의 프리틸트각 제어)

  • Kang, Hyung-Ku;Kim, Young-Hwan;Kim, Jong-Hwan;Han, Jin-Woo;Kang, Soo-Hee;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.311-312
    • /
    • 2005
  • By using 45$^{\circ}$ obliqued evaporation method with electron beam system, uniformly vertical liquid crystal (LC) alignment was achieved. And a high pretilt angles of about 2.5$^{\circ}$ were measured. Also, it was verified that there are no variations of pretilt angle as a function of $SiO_x$ thin film thickness 20nm and 50nm. A good LC alignment states were observed at annealing temperature of 250$^{\circ}C$. The high pretilt angle and the good thermal stability of LC alignment by 45$^{\circ}$ obliqued electron beam evaporation method on the $SiO_x$ thin film can be achieved.

  • PDF

Liquid Crystal Alignment Effects on SiOx Thin Film by Electron Beam Evaporation Method (전자빔증착법을 통한 SiOx 박막의 액정 배향 효과)

  • Kang, Hyung-ku;Han, Jin-Woo;Kang, Soo-Hee;Kim, Jong-Hwan;Kim, Young-Hwan;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1024-1027
    • /
    • 2005
  • By using $45^{\circ}$ obliqued evaporation method with electron beam system, uniformly vertical liquid crystal (LC) alignment was achieved. And a high pretilt angles of about $2.5^{\circ}$ were measured. Also, it was verified that there are no variations of pretilt angle as a function of $SiO_x$ thin film thickness 20 nm and 50 nm. A good LC alignment states were observed at annealing temperature of $250^{\circ}C$. Consequently, the high pretilt angle and the good thermal stability of LC alignment by $45^{\circ}$ obliqued electron beam evaporation method on the $SiO_x$ thin film can be achieved.

Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)

  • Golge, Ozgur;Liman, Turan;Kabak, Bulent
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.816-825
    • /
    • 2021
  • This study aims to validate a fast method of simultaneous analysis of 365 LCamenable and 142 GC-amenable pesticides in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively, operating in multiple reaction monitoring (MRM) acquisition modes. The sample preparation was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction. Key method performance parameters investigated were specificity, linearity, limit of quantification (LOQ), accuracy, precision and measurement uncertainty. The method was validated at two spiking levels (10 and 50 ㎍/kg), and good recoveries (70%-120%) and relative standard deviations (RSDs) (≤20) were achieved for 92.9% of LC-amenable and 86.6% of GC-amenable pesticide residues. The LOQs were ≤10 ㎍/kg for 94.2% of LC-amenable and 92.3% of GC-amenable pesticides. The validated method was further applied to 100 egg samples from caged hens, and none of the pesticides was quantified.

Development and validation of an analytical method to quantify baphicacanthin A by LC-MS/MS and its application to pharmacokinetic studies in mice

  • Jeon, So Yeon;Kim, San;Park, Jin-Hyang;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.60-68
    • /
    • 2022
  • In this study, we developed and validated a sensitive analytical method to quantify baphicacanthin A in mouse plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The standard calibration curves for baphicacanthin A ranged from 0.5 to 200 ng/mL and were linear, with an r2 of 0.985. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. Besides, we investigated the pharmacokinetics of baphicacanthin A following its intravenous (5 mg/kg) and oral administration (30 mg/kg). Intravenously injected baphicacanthin A showed biphasic elimination kinetics with high clearance and volume of distribution values. Furthermore, baphicacanthin A showed a rapid absorption but low aqueous solubility (182.51±0.20 mg/mL), resulting in low plasma concentrations and low oral bioavailability (2.49 %). Thus, we successfully documented the pharmacokinetic properties of baphicacanthin A using this newly developed sensitive LC-MS/MS quantification method, which could be used in future lead optimization and biopharmaceutic studies.