• Title/Summary/Keyword: LC-MS/MS method

Search Result 599, Processing Time 0.027 seconds

Development of Multi-residue Analytical Method for 261 Pesticides in Herbal Medicines using GC-MS/MS and LC-MS/MS (GC-MS/MS와 LC-MS/MS를 이용한 생약재 중 261종 농약의 동시분석)

  • Na, Eun Shik;Kim, Seong Soo;Hong, Sung Soo;Kim, Kyoung Ju;Lee, Yong Jae;Lee, Byung Chul;Lee, Kyu Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.2
    • /
    • pp.142-169
    • /
    • 2020
  • BACKGROUND: A new analytical method has been developed to determine 261 pesticide residues in herbal medicines. METHODS AND RESULTS: The extraction of pesticides was carried out by modified method of the Korea Food Standards Codex sample extraction and determination was performed using GC-MS/MS and LC-MS/MS. During the pre-treatment process of the test method, Solid-liquid separation was changed to centrifugation. The method was validated by the precision and accuracy results. 261 pesticides spiked at three level 20, 50, 100 ug/kg in herbal medicines. The limit of quantification of method were 4-40 ug/kg for GC-MS/MS and 2-45 ug/kg for LC-MS/MS, respectively. Among the pesticides analysed by GC-MS/MS and LC-MS/MS, 244 pesticides (94% of total number) in chinese matrimony vine and 224 pesticides (86% of total number) in korean angelica root and 231 pesticides (89% of total number) in jujube and 214 (82% of total number) in cnidium showed recoveries in the range of 70-120% with RSD⪯20%. CONCLUSION: These results indicated that GC-MS/MS and LC-MS/MS analysis with the sample extraction in this study can be applied to multi-residue analysis of pesticides in herbal medicines.

Evaluation of the Method for Total Homocysteine in Plasma Using LC-MS/MS (LC-MS/MS를 이용한 Homocysteine 측정과 그 유용성 평가)

  • Jun, Sun-Hee;Lim, Mi-Suk;Jung, Yong-Sun;Song, Jung-Han
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • Total homocysteine is now considered a risk factor for cardiovascular diseases. I increased interest has led to a multitude of studies requiring the determination of total homocysteine in conjunction with other factor. There are various methods for measuring total homocysteine, including HPLC, FPIA, GC-MS and LC-MS/MS. The most recent method for measuring total homocysteine uses a deuterium-labelled internal standard and tandem mass spectrometry. This development requires no derivatization and therefore leads to an increase in sample throughput compared to other techniques. We have evaluated the method for homocysteine by the LC-MS/MS method, and the correlation between the FPIA method and the LC-MS/MS method. The standard curve (0, 5, 10, 20, 50, 100 uM) was linear over the range examined (up to 100 uM). The lower limit of quantification (CV < 10 %) was 0.5 uM/L and the lower limit of detection (S/N >3) was 0.1 uM/L. Intra-assay variation and inter-assay variation were both <6 %. The comparision study for homocysteine concentration showed good correlation (r=0.9684) between the FPIA method and LC-MS/MS methods. Our conclusion is that the method showed relatively good precision, and was rapid and accurate.

  • PDF

Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry (LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Kim, Joohye;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.110-117
    • /
    • 2018
  • The aim of this study was to develop an analytical method for the quantification of diazepam residues in fishery products, using liquid and gas chromatography-tandem mass spectrometry (LC-MS/MS and GC-MS/MS). The sample utilized in the study was extracted from the fish sample (crucian carp) using 0.1% formic acid in acetonitrile. For the utilization of the purification process, the dispersive solid phase extraction (dSPE) was used for LC-MS/MS, dSPE and SPE was used for GC-MS/MS, respectively. To be sure, the standard calibration curves showed a good linearity as the noted correlation coefficients, $r^2$ was > 0.99. The average recoveries for accuracy ranged in 99.8~124% for the samples which were fortified at three different levels (0.001, 0.002 and 0.010 mg/kg). The correlation coefficient for the precision effect was measured at a range of 4.01~11.8%. The limit of detection (LOD) for the diazepam analysis was 0.0004 mg/kg, and the limit of the quantification (LOQ) was 0.001 mg/kg. The proposed analytical method was characterized with a high accuracy and acceptable sensitivity to meet the established Codex Alimentarius Commission (CAC/GL71-2009) guideline requirements. We therefore established the optimal analysis method for the determination of diazepam in the fishery products using LC-MS/MS and GC-MS/MS. It would be applicable to analyze the diazepam residues in fishery products in further studies on this subject.

Development of Multi-residue Analysis of 320 Pesticides in Apple and Rice Using LC-MS/MS and GC-MS/MS (LC-MS/MS와 GC-MS/MS를 이용한 사과와 쌀 시료에서 320종 농약의 다성분 분석)

  • Kim, Jong-Hwan;Kim, Yeong-Jin;Kwon, Young-Sang;Seo, Jong-Su
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.2
    • /
    • pp.104-127
    • /
    • 2016
  • A new analytical method has been developed to determine 320 pesticides in apple and rice. The extraction of pesticides was carried out based on QuEChERS sample extraction, and determination was performed using LC-MS/MS and GC-MS/MS. 320 pesticides were selected for experiments. 251 and 110 pesticides among them were analysed by LC-MS/MS and GC-MS/MS, respectively. 41 pesticides of them were analyzed by both GC-MS/MS and LC-MS/MS. Among pesticides analysed by LC, 242 pesticides (96% of total number) in apple and 237 pesticides (94% of total number) in rice showed recoveries in the range of 70~120% with RSD ${\leq}20%$. In case of pesticides analyzed by GC-MS/MS, 103 pesticides (94% of total number) in apple and 83 pesticides (76% of total number) in rice were successfully validated. These results indicated that LC-MS/MS and GC-MS/MS analysis with the QuEChERS sample preparation can be partly applied to multi-residue pesticides in agricultural products.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Comparison of 2-D RP-RP MS/MS with 1-D RP MS/MS for Proteomic Analysis (단백체 분석을 위한 일차원 및 이차원 역상크로마토그래피의 비교)

  • Moon, Pyong-Gon;Cho, Young-Eun;Baek, Moon-Chang
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.377-386
    • /
    • 2010
  • Single-dimensional (1-D) and two-dimensional (2-D) LC methods were utilized to separate peptides from various sources followed by MS/MS analysis. Two-dimensional ultra-high performance liquid chromatography is a useful tool for proteome analysis, providing a greater peak capacity than 1-D LC. The most popular 2-D LC approach used today for proteomic research combines strong cation exchange and reversed-phase LC. We have evaluated an alternative mode for 2-D LC of peptides using 2-D RP-RP nano UPLC Q-TOF Mass Spectrometry, employing reversed-phase columns in both separation dimensions. As control experiments, we identified 129 proteins in 1-D LC and 322 proteins in 2-D LC from E. coli extract peptides. Furthermore, we applied this method to rat primary hepatocyte and a total of 170 proteins were identified from 1-D LC, and 527 proteins were identified from all 2-D LC system. The in-depth protein profiling established by this 2-D LC MS/MS from rat primary hepatocyte could be a very useful reference for future applications in regards to drug induced liver toxicity.

A Sensitive Method for Identification of N-Glycosylation Sites and the Structures of N-Glycans Using Nano-LC-MS/MS (나노 액체크로마토그래피-텐덤 질량분석기를 이용하여 N-당질화 위치 및 N-당사슬 구조 규명을 위한 방법)

  • Cho, Young-Eun;Kim, Sook-Kyung;Baek, Moon-Chang
    • YAKHAK HOEJI
    • /
    • v.57 no.4
    • /
    • pp.250-257
    • /
    • 2013
  • Biosimilars are important drugs in medicine and contain many glycosylated proteins. Thorough analysis of the glycosylated protein is a prerequisite for evaluation of biosimilar glycan drugs. A method to assess the diversity of N-glycosylation sites and N-glycans from biosimilar glycan drugs has been developed using two separate methods, LC-MS/MS and MALDI-TOF MS, respectively. Development of sensitive, accurate, and efficient methods for evaluation of glycoproteins is still needed. In this study, analysis of both N-glycosylation sites and N-glycans of glycoprotein was performed using the same LC-MS/MS with two different nano-LC columns, nano-C18 and nano-porous graphitized carbon (nano-PGC) columns. N-glycosylated proteins, including RNAse B (one N-glycosylation site), Fetuin (three sites), and ${\alpha}$-1 acid glycoprotein (four sites), were used, and small amounts of each protein were used for identification of N-glycosylation sites. In addition, high mannose N-glycans (one type of typical glycan structure), Mannose 5 and 9, eluted from RNAse B, were successfully identified using nano-PGC-LC MS/MS analysis, and the abundance of each glycan from the glycoprotein was calculated. This study demonstrated an accurate and efficient method for determination of N-glycosylation sites and N-glycans of glycoproteins based on high sensitive LC-MS/MS using two different nano-columns; this method could be applied for evaluation of the quality of various biosimilar drugs containing N-glycosylation groups.

Validation of LC-MS/MS Method for Analysis of Paralytic Shellfish Toxins in Shellfish and Tunicates (LC-MS/MS를 이용한 패류 및 피낭류 중 마비성 패류독소 분석법의 유효성 검증)

  • Cho, Sung Rae;Kim, Dong Wook;Yu, Hean Jae;Cho, Seong Hae;Ryu, Ara;Lee, Ka Jeong;Mok, Jong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.2
    • /
    • pp.174-180
    • /
    • 2020
  • The mouse bioassay has been used widely for the monitoring of paralytic shellfish toxins (PSTs) in many countries. However, this method shows low sensitivity and high limit of detection (LOD), as well as it cannot confirm toxic profiles. Recently, LC-MS/MS method was studied for the quantitative of PSTs, however, the method has any problems with unstable retention times by ionization suppression caused by high salt concentration in shellfish extracts. To establish an alternative method for PSTs analysis, we tried to original LC-MS/MS methods adding desalting operation using amorphous graphitized polymer carbon solid-phase extraction cartridges. The method validation was conducted to determine linearity, limit of detection, limit of quantification (LOQ), accuracy, and precision in quantifying PSTs. The correlation coefficients for all tested PSTs maintained over 0.999. The LODs and LOQs for all PSTs were about 0.19-1.05 ㎍/kg and 0.58-3.18 ㎍/kg, respectively. The accuracies for PSTs were 95.4-107.7% for saxitoxin group, 97.1-100.9% for gonyautoxin group, 99.0-100.8% for N-sulfocarbamoyl toxin group, and 96.8-104.6% for decarbamoyl toxin group. These results indicate that the modified LC-MS/MS method was appropriate for analyzing the PSTs in shellfish and tunicates.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.

Educational Peptide Mapping of Protein-based Biopharmaceuticals by using LC-MS/MS (LC-MS/MS를 이용한 단백질 의약품 맵핑 교수법)

  • Kim, Junseok
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.327-332
    • /
    • 2022
  • This experiment presents a precise analysis method using a mass spectrometer in the biopharmaceutical market, where utility is expanding. Among various techniques for analyzing the protein drug, somatotropin, the peptide fragments through biochemical sample preparation was analyzed by LC-MS/MS characterization. The analysis process was performed by separation analysis using nanoUPLC and MS/MS analysis using Orbitrap. In the case of somatotropin with 21 tryptic peptides, 13 of them were consistent with theoretical predictions within an average of 1 ppm error.