• Title/Summary/Keyword: LC design

Search Result 393, Processing Time 0.03 seconds

A Continuously Tunable LC-VCO PLL with Bandwidth Linearization Techniques for PCI Express Gen2 Applications

  • Rhee, Woo-Geun;Ainspan, Herschel;Friedman, Daniel J.;Rasmus, Todd;Garvin, Stacy;Cranford, Clay
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.3
    • /
    • pp.200-209
    • /
    • 2008
  • This paper describes bandwidth linearization techniques in phase-locked loop (PLL) design for common-clock serial link applications. Utilizing a continuously tunable single-input dual-path LC VCO and a constant-gain phase detector, a proposed architecture is well suited to implementing PLLs that must be compliant with standards that specify minimum and maximum allowable bandwidths such as PCI Express Gen2 or FB-DIMM applications. A prototype 4.75 to 6.1-GHz PLL is implemented in 90-nm CMOS. Measurement results show that the PLL bandwidth and random jitter (RJ) variations are well regulated and that the use of a differentially controlled dual-path VCO is important for deterministic jitter (DJ) performance.

An improved electrode structure of the Patterned Vertical Alignment Liquid Crystal Cell for high optical property

  • Choi, Yong-Hyun;Son, Jung-Hee;Yang, Jin-Seok;Ji, Seung-Hoon;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.502-505
    • /
    • 2007
  • In this paper we propose a novel electrode structure for high transmittance in the Patterned Vertical Alignment (PVA) LC cell. Normally, the transmittance of PVA LC cell is depended on the shape of the electrode and cell gap. We studied the area decreasing the transmittance through the electrode structure for wide viewing angle and proposed new electrode design to change LC director configuration in the area. We use the 'TechWiz LCD' for calculation of the director configuration and optical characteristics. We show the comparison of the calculated optical transmittance between the conventional PVA mode and the proposed PVA mode. From the results, we confirm that the optical transmittance of the proposed structure of the PVA cell becomes higher.

  • PDF

Comparison of Two Layout Options for 110-GHz CMOS LC Cross-Coupled Oscillators

  • Kim, Doyoon;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.141-143
    • /
    • 2018
  • Two 110-GHz oscillators have been developed in 65-nm CMOS technology. To study the effect of layout on the circuit performance, both oscillators had the same LC cross-coupled topology but different layout schemes of the circuit. The oscillator with the conventional cross-coupled design (OSC1), showed an output power of -3.9 dBm at 111 GHz with a phase noise of -75 dBc/Hz at 1-MHz offset. On the other hand, OSC2, with a modified cross-coupled line layout, generated an output power of -2.0 dBm at 117 GHz with a phase noise of -77 dBc/Hz at 1-MHz offset. The result indicates that the optimized layout can improve key oscillator performances such as oscillation frequency and output power.

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

Design of a lenticular lens array module for stereoscopic vision application (입체영상을 위한 렌티큘러 렌즈 어레이 설계)

  • 김현영;박헌용;이은녕;조성민;심용식;이승걸;오범환;박세근;이일항
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.118-119
    • /
    • 2003
  • 조명각 변조방식에 의한 3차원 디스플레이 모듈의 구성요소는 back light unit(BLU), stripe-patterned LC shutter, lenticular lens sheet이다. 이런 3차원 디스플레이 에서 조명각도의 올바른 변조를 위해서는 stripe-patterned LC shutter, lenticular lens sheet 상호 결합이 가장 중요하다. 그림 1 은 이러한 입체영상 module의 개념도이다. 그림과 같이 LC shutter위에 적절한 렌티큘러 렌즈 어레이를 설치할 때, 줄무늬 모양의 면 광원에서 방출된 빛이 한번은 정확히 오른쪽 눈으로 다음 번에는 왼쪽 눈으로 향하게 하여 양안 시차에 의해 3D영상이 보이도록 하는 것이 이 모듈의 핵심원리이다. (중략)

  • PDF

Do-It-Yourself (DIY) manufacture of a Nano-LC MALDI spotter robot using 3D printing technology

  • Lee, Jae-ung;Oh, Han Bin
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.167-173
    • /
    • 2017
  • In the era of the forth Industrial Revolution, open source code and open source hardware have gained much attention. In particular, 3D printing technology is expanding into the realms of classical science, technology and our daily lives. Relatedly, in the present study, we demonstrate the manufacture of a nano-LC MALDI spotter robot using 3D printing technology. The parts of the spotter robot were either made using a 3D printer or purchased as 3D printer parts from the 3D printer online market, so that anyone can make the robot without a deep knowledge of engineering or electronics, i.e., DIY (do-it-yourself) product. In the nano-LC MALDI spotter, the nano-LC eluent and MALDI matrix were mixed in a T-union and discharged from the capillary outlet. The eluent and matrix mixture could be spotted onto the movable MALDI plate. The MALDI plate was designed to translate in a two-dimensional space (xy plane), which was enabled by the movements of two stepper motors. In the paper, all computer-aided design (CAD) files for the parts and operation software are provided to help the reader manufacture their own spotter robot.

Molecular Characterization of Some Antilisterial Bacteriocin Genes from Enterococcus faecium and Pediococcus pentosaceus

  • El-Arabi, Nagwa I.;Salim, Rasha G.;Abosereh, Nivien A.;Abdelhadi, Abdelhadi A.
    • Microbiology and Biotechnology Letters
    • /
    • v.46 no.3
    • /
    • pp.288-299
    • /
    • 2018
  • Food bio preservation is of major interest in the food industry. Many types of antimicrobial compounds can be produced by lactic acid bacteria (LAB), including bacteriocins. Bacteriocins increase the shelf-life of food by decreasing some food-borne diseases. In this study, a multi-coding sequence of bacteriocin genes was used for primer design to produce bacteriocin genes in Enterococcus faecium AH2 strain and Pediococcus pentosaceus AH1. Multi-coding sequences were aligned to detect conserved sequences in the bacteriocin gene. Eight genes encoding proteins involved in bacteriocin production were isolated and sequenced, including six from E. faecium AH2 (entA, entI, entF, entR, orfA2, orfA3) and two from P. pentoceseus AH1 (papA, pedB), and all gene sequences were deposited in the Gen Bank database under accession numbers LC064146-LC064151, LC101300, and LC101789, respectively. P. pentosaceus AH1 and E. faecium AH2 strains displayed bacteriocin activities of $2610AU\;mL^{-1}$ and $690AU\;mL^{-1}$ and inhibition zones of 26 mm and 19 mm, respectively. Overexpression of entA in E. faecium AH2 increased the bacteriocin and antimicrobial activities.

Factors influencing Symptom Experience in Patients with Liver Cirrhosis (간경변 환자의 증상경험에 영향을 미치는 요인)

  • Kim, Soo Hyun
    • Korean Journal of Adult Nursing
    • /
    • v.17 no.2
    • /
    • pp.248-258
    • /
    • 2005
  • Purpose: The purpose of this study is to examine the factors influencing symptom experience in patients with liver cirrhosis(LC). Method: A descriptive correlational study design was used. A convenience sample of 129 subjects was recruited from the gastroenterology department at two university hospitals in Seoul, Korea. Symptom experience in LC was measured with the instrument developed by the researcher based on Theory of Unpleasant Symptoms(Lenz et al, 1995) and the Child-Pugh Score, the Korean version of Profile of Mood States, and the Family Support Questionnaire were used to identify the factors influencing symptom experience. Results: The mean score of symptom experience was relatively low(M=41.67, SD= 24.71). Among individual symptoms, fatigue had the highest score in all dimensions. Fatigue, abdominal distension and/or peripheral edema, muscle cramps, dry mouth, and change in appearance were explored as symptoms needing management. In the regression analysis, symptom experience was found to be influenced significantly by anxiety/depression($R^2=.418$, p=.000) and the severity of LC(Child-Pugh Score)($R^2=.125$, p=.000). These variables explained 54.3% of the variance in symptom experience(F=63.607. p=.000). Conclusion: It suggests that nurses need to take into consideration psychological factor as well as physiological factor in symptom management for patients with LC.

  • PDF

A Low Power Fast-Hopping Frequency Synthesizer Design for UWB Applications (UWB 응용을 위한 저전력 고속 스위칭 주파수 합성기의 설계)

  • Ahn, Tae-Won;Moon, Je-Cheol;Kim, Yong-Woo;Moon, Yong
    • 전자공학회논문지 IE
    • /
    • v.45 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • A fast-hopping frequency synthesizer that reduces complexity and power consumption is presented for MB-OFDM UWB applications. The proposed architecture uses 3960 MHz LC VCO, 528 MHz ring oscillator, passive mixer and LC-tuned Q-enhancement BPF to generate Band Group 1 frequencies. The adjacent channel rejection ratio is less than -40 dBc for 3432 MHz and -H dBc for 4488 MHz. A fast switching SCL-tpre MUX is used to produce the required channel output signal and it takes less than 2.2 ns for band switching. The total power consumption is 47.9 mW from a 1.8 V supply.

Design of a Low-Pressure Hydrocyclone with Application for Fine Settleable Solid Removal Using Substitute Polystyrene Particles

  • Lee, Jin-Hwan;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.18 no.3
    • /
    • pp.189-195
    • /
    • 2005
  • By testing the separation performance for a fine settleable solid removal system in an aquaculture system using polystyrene particles as an experimental substitute, the optimal geometric dimensions for a Low-Pressure Hydrocyclone (LPH) were obtained. The design approach far the LPH took into consideration two inflow diameters (Di: 30, 50 mm), three overflow diameters (Do: 60, 70, 100 mm) and four cylinder lengths (Lc: 250, 345, 442, 575 mm), while the cylinder diameter (Dc) at 335 mm, the underflow diameter (Du) at 50 mm and the cone angle (${\theta}$) at $68^{\circ}$ were kept constant. The separation performances of 19 different dimension combinations of LPH were tested, ranging from 300 to 1200 ml/sec of inflow rate using substitute polystyrene particles (0.4-0.7 mm dia., ${\rho}_s=1.05g/cm^3$). These polystyrene particles exhibit a similar density and settling velocity to the fine fecal debris of the common carp. The total separation efficiency for the inflow rate ranged from a high of 97% to a low of 20%. Experimental results obtained by ANCOVA and the Tukey test (${\alpha}=0.05$) showed that the separation performances of the LPH were significantly affected (P<0.05) by the fi, Di, Do and Lc. The maximum separation performance was detected at a dimension combination of 30 mm of inflow diameter (Di), 60 mm of overflow diameter (Do), 442 and 575 mm of cylinder length (Lc). The dimension proportions were 0.09, 1.32-1.72, 0.18 and 0.15 for Di/Dc, Lc/Dc, Do/Dc and Du/Dc respectively.