• Title/Summary/Keyword: LC/tandem MS

Search Result 354, Processing Time 0.035 seconds

Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)

  • Golge, Ozgur;Liman, Turan;Kabak, Bulent
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.816-825
    • /
    • 2021
  • This study aims to validate a fast method of simultaneous analysis of 365 LCamenable and 142 GC-amenable pesticides in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively, operating in multiple reaction monitoring (MRM) acquisition modes. The sample preparation was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction. Key method performance parameters investigated were specificity, linearity, limit of quantification (LOQ), accuracy, precision and measurement uncertainty. The method was validated at two spiking levels (10 and 50 ㎍/kg), and good recoveries (70%-120%) and relative standard deviations (RSDs) (≤20) were achieved for 92.9% of LC-amenable and 86.6% of GC-amenable pesticide residues. The LOQs were ≤10 ㎍/kg for 94.2% of LC-amenable and 92.3% of GC-amenable pesticides. The validated method was further applied to 100 egg samples from caged hens, and none of the pesticides was quantified.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Determination and confirmation of the carbendazim residue in soybean sprout (콩나물중 살균제 carbendazim 잔류분의 정량 및 확인)

  • Kim, Young-Gook;Park, Jong-Tae;Hong, Suk-Soon
    • The Korean Journal of Pesticide Science
    • /
    • v.2 no.3
    • /
    • pp.79-84
    • /
    • 1998
  • Tandem HPLC and atmospheric pressure chemical ionization(APcI) LC/MS method was used for the determination and confirmation of carbendazim residues in soybean sprout. Fluorescence(FL) detector was connected in tandem with the ultraviolet(UV) detector for dual detection of the carbendazim residue at the excitation and emission wavelength of 280 nm and 310 nm, respectively. The limit of detection for carbendazim was $0.1{\mu}g/kg$ sample. Recoveries of carbendazim from fortified soybean sprout at 0.5, 1.0 and 2.0 ppm were averaged 89.1%. Mass spectrometry using a APcI source confirmed the carbendazim residue in the soybean sprout sample. Fragmentation pattern on the APcI LC/MS spectrum of carbendazim was simpler than that from electron impact(EI) mass spectrum. Carbendazim produced 3 major ions including m/z 133, m/z 159 and m/z 191($M^{+}$). This method was sensitive enough to provide reliable and reproducible results for practical applications.

  • PDF

Simultaneous and quantitative determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (토양 중 음이온 바이오사이드의 HPLC-MS/MS 동시 정량분석법)

  • Yang, Eun-Young;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.317-322
    • /
    • 2015
  • Simultaneous analytical method has developed for the determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chlorite and chlorate in soil were extracted with pure water, and cyanuric acid and sodium dodecylbenzenesulfonate (Na-DBS) were extracted with mobile phase (0.25 mM ammonium formate in 20 mM formic acid : acetonitrile (1:1)). The extract was injected into the LC-MS/MS system after filtration. The method detection limits in this study were 0.04 mg/kg for chlorite, 0.04 mg/kg for chlorate, 0.27 mg/kg for cyanuric acid, and 0.05 mg/kg for Na-DBS, respectively. The method was applied to the analysis of 50 soil samples collected from 40 sites sprayed with biocides and 10 background sites. As a result, anion biocides were not detected in all sites.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.

Verification of Analytical Method of Azaspiracid Toxins in Shellfish and Tunicates by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry)를 이용한 패류 및 피낭류 중 아자스필산 분석법의 유효성 검증)

  • Cho, Sung Rae;Jeong, Sang Hyeon;Park, Kunbawui;Yoon, Minchul;Kim, Dong Wook;Son, Kwang Tae;Ha, Kwang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.4
    • /
    • pp.404-410
    • /
    • 2021
  • Although, mouse bioassay for the monitoring of azaspiracids (AZAs) toxins in shellfish has been used previously, the reported method has low sensitivity and it is time-consuming. Recently, there is an interest in the quantitative analysis of AZAs using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The purpose of this study is to verify the simultaneous analysis of AZAs in shellfish and tunicate in Korea using LC-MS/MS. To validate the method, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and repeatability were determined. All standard compounds were analyzed within 7 min. The correlation coefficients (R2) of the standard solution was higher than 0.9995 (within the range of 0.8-10.0 ㎍/L). The LODs and LOQs of AZAs in shellfish were 0.08-0.16 ㎍/kg and 0.23-0.50 ㎍/kg, respectively. The accuracy and precision of the method for determining AZAs in shellfish were 87.1-93.0% and 1.23-4.91%, respectively. Consequently, the verified LC-MS/MS method is suitable to analyze AZAs in shellfish and tunicates in Korea.

Analysis of streptomycin in honey by LC-MS/MS (LC-MS/MS를 이용한 벌꿀 중 스트렙토마이신 분석)

  • Shim, Young-Eun;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.424-431
    • /
    • 2008
  • Streptomycin, which is one of aminoglycoside antibiotics, has been widely used in the rearing of food-producing animals to prevent and treat diseases in cattle, pigs and poultry. Although not licensed in South Korea, streptomycin has also been used for the treatment of bacterial honeybee disease, such as European foulbrood in Third World countries. A reliable and effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of streptomycin in honey. A established method was optimized the clean-up and extraction procedure for the trace determination, good precision and accuracy. And the chromatographic and tandem mass spectrometric parameters were also optimized. The precision (RSD) and accuracy (bias) in the concentration range of 5.0~50.0 ug/kg were 5.5~14% and -10.0~8.0%, respectively. Limit of detection was 0.75 ug/kg and recovery of streptomycin spiked at level of 10 ug/kg in honey was 74%. The established and validated method was applied to determine streptomycin in honey which was on the market.

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

Analysis of LC-MS/MS in Discrimination of the Origin of Commercial Red Ginseng Concentrates (시판 홍삼농축액의 원산지 판별을 위한 LC-MS/MS 분석)

  • Moon, Ji Young;Han, Hyun Jung;Dong, Hyemin;Park, Su Won;Kim, Hyun Jung;Bang, Kyong-Hwan;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.549-555
    • /
    • 2014
  • The geographical origin of commercial red ginseng concentrate was studied using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The ginsenoside content of domestic and Chinese red ginseng concentrates was determined. Four types of suspected origin samples could be selected this technique. The LC-MS/MS data were statistically analyzed on the basis of canonical function analysis and principal component analysis. Domestic and Chinese samples could be discriminated via canonical function analysis using posterior probability. In addition, the mixture ratio (Korean or Chinese origin) of the unknown origin specimen could be predicted based on the relationship between the mixing concentration of red ginseng concentrates and principal component 1.