• Title/Summary/Keyword: LAMP(Loop Mediated Isothermal Amplification)

Search Result 89, Processing Time 0.02 seconds

Loop-mediated Isothermal Amplification (LAMP) for Detection of Streptococcus parauberis (Loop-mediated isothermal amplification (LAMP)법을 이용한 Streptococcus parauberis 의 신속 진단)

  • Moon, Kyung-Mi;Kim, Dong-Hwi;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.24 no.4
    • /
    • pp.428-436
    • /
    • 2014
  • Loop-mediated isothermal amplification (LAMP) technique relies on autocycling strand displacement DNA sysnthesis without template denaturation steps under isothermal conditions. LAMP has more advantages than modern PCR, as it requires only basic laboratory equipment like an isothermal water bath, oven, and heating cabinet. Hence, in this study, five random primers were designed with Streptococcus parauberis, shikimate kinase Arok gene sequences (Genbank accession number: CP0024711). Two primers were selected based on the ladder pattern. Other optimum reaction conditions like temperature, time, and sensitivity were established and confirmed with conventional SYBR-green PCR. Results confirmed that the designed random primers were species specific, without any non-target DNA amplification under isothermal conditions. Hence, this study suggests that LAMP techniques could be used in the diagnosis of fish pathogen, specifically S. parauberis.

Detection of Salmonella typhi by Loop-mediated Isothermal Amplification Assay

  • Jo, Yoon-Kyung;Lee, Chang-Yeoul
    • Biomedical Science Letters
    • /
    • v.14 no.2
    • /
    • pp.115-118
    • /
    • 2008
  • Salmonella typhi is frequent causes of foodborne illness and its detection is important for monitoring disease progression. In this study, by using general PCR and novel LAMP (Loop Mediated Isothermal Amplification) assay, we evaluated the usefulness of LAMP assay for detection of Salmonella typhi. In this LAMP assay, forward inner primer (FIP) and back inner primer (BIP) was specially designed for recognizing target invA gene. Target DNA was amplified and visualized as ladder-like pattern of bands on agarose gel within 60 min under isothermal conditions at $65^{\circ}C$. When the sensitivity and reproducibility of LAMP were compared to general PCR, there was no difference of reproducibility but sensitivity of LAMP assay was more efficient than PCR (the detection limit of LAMP assay was 30 fg, while the PCR assay was 3 pg). These results indicate that the LAMP assay is a potential and valuable means for detection of Salmonella typhi, especially for its rapidity, simplicity and low cost.

  • PDF

Development of a Rapid Detection Method for Pectobacterium carotovorum subsp. carotovorum Using the Loop-Mediated Isothermal Amplification (LAMP) (Loop-Mediated Isothermal Amplification (LAMP)법을 이용한 Pectobacterium carotovorum subsp. carotovorum의 신속 진단법 개발)

  • Kim, Jeong-Gu;No, Ji-Na;Park, Dong-Suk;Yoon, Byoung-Su
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.103-109
    • /
    • 2011
  • Pectobacterium carotovorum subsp. carotovorum is the causative agent of soft rot in crops such as potato and cabbages. Loop-mediated isothermal amplification (LAMP) is a simple DNA amplification method, as well as isothermal PCR technique. In this study, a new method for the rapid detection of Pectobacterium carotovorum subsp. carotovorum was developed using LAMP that named PCC-LAMP. Based on lytic murein transglycolase gene of Pectobacterium carotovorum subsp. carotovorum, a set of four primers for LAMP was designed. The optimal PCC-LAMP reaction temperature was established at $61^{\circ}C$. Under standard conditions, PCC-LAMP amplified $1{\times}10^3$ copies of clone PCC-pBX437 per reaction. Further, this method can also assay directly by SYBR Green I without electrophoresis. Amplification was not detected for five other bacterial species. In conclusion, PCC-LAMP may be a useful method for the detection Pectobacterium carotovorum subsp. carotovorum in the field.

Loop-mediated Isothermal Amplification Assay to Rapidly Detect Wheat Streak Mosaic Virus in Quarantined Plants

  • Lee, Siwon;Kim, Jin-Ho;Choi, Ji-Young;Jang, Won-Cheoul
    • The Plant Pathology Journal
    • /
    • v.31 no.4
    • /
    • pp.438-440
    • /
    • 2015
  • We developed a loop-mediated isothermal amplification (LAMP) method to rapidly diagnose Wheat streak mosaic virus (WSMV) during quarantine inspections of imported wheat, corn, oats, and millet. The LAMP method was developed as a plant quarantine inspection method for the first time, and its simplicity, quickness, specificity and sensitivity were verified compared to current reverse transcription-polymerase chain reaction (RT-PCR) and nested PCR quarantine methods. We were able to quickly screen for WSMV at quarantine sites with many test samples; thus, this method is expected to contribute to plant quarantine inspections.

Development of Diagnostic Technology of Xylella fastidiosa Using Loop-Mediated Isothermal Amplification and PCR Methods

  • Kim, Suyoung;Park, Yujin;Kim, Gidon
    • Research in Plant Disease
    • /
    • v.27 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • Xylella fastidiosa is the most damaging pathogen in many parts of the world. To increase diagnostic capability of X. fastidiosa in the field, the loop-mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR) assay were developed to mqsA gene of citrate-synthase (XF 1535) X. fastidiosa and evaluated for specificity and sensitivity. Both assays were more robust than current published tests for detection of X. fastidiosa when screened against 16 isolates representing the four major subgroups of the bacterium from a range of host species. No cross reaction with DNA from healthy hosts or other species of bacteria has been observed. The LAMP and PCR assays could detect 10-4 pmol and 100 copies of the gene, respectively. Hydroxynaphthol blue was evaluated as an endpoint detection method for LAMP. There was a significant color shift that signaled the existence of the bacterium when at least 100 copies of the target template were present.

Rapid and sensitive detection of Salmonella species targeting the hilA gene using a loop-mediated isothermal amplification assay

  • Chu, Jiyon;Shin, Juyoun;Kang, Shinseok;Shin, Sun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.19 no.3
    • /
    • pp.30.1-30.8
    • /
    • 2021
  • Salmonella species are among the major pathogens that cause foodborne illness outbreaks. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of Salmonella species. We designed LAMP primers targeting the hilA gene as a universal marker of Salmonella species. A total of seven Salmonella species strains and 11 non-Salmonella pathogen strains from eight different genera were used in this study. All Salmonella strains showed positive amplification signals with the Salmonella LAMP assay; however, there was no non-specific amplification signal for the non-Salmonella strains. The detection limit was 100 femtograms (20 copies per reaction), which was ~1,000 times more sensitive than the detection limits of the conventional polymerase chain reaction (PCR) assay (100 pg). The reaction time for a positive amplification signal was less than 20 minutes, which was less than one-third the time taken while using conventional PCR. In conclusion, our Salmonella LAMP assay accurately detected Salmonella species with a higher degree of sensitivity and greater rapidity than the conventional PCR assay, and it may be suitable for point-of-care testing in the field.

Development of diagnostic method for human Astrovirus with rapid, specific and high sensitivity using loop-mediated isothermal amplification method

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.1
    • /
    • pp.173-182
    • /
    • 2020
  • Human Astrovirus (HuAstV), known as a waterborne virus, is a group IV positive-sense single-stranded RNA that belongs to Astroviridae. The first outbreak of HuAstV was reported in England in 1975. HuAstV can exist not only among clinical patients but also in various water environments, such as water for agriculture and vegetables. For diagnosis of HuAstV from water samples, a polymerase chain reaction (PCR) system has been developed. However, the PCR-based diagnostic method has problems in field application, such as reaction time, sensitivity and specificity. For this reason, in this study we developed the loop-mediated isothermal amplification assay (LAMP) system, aimed specifically at HuAstV. Three prepared LAMP primer sets were tested by specificity, non-specificity and sensitivity; one LAMP primer set was selected with optimum reaction temperature. The developed LAMP primer set reaction conditions were confirmed at 62℃, and detection sensitivity was 1 fg/μL. In addition, restriction enzyme HaeIII (GG/CC) was introduced to confirm that the LAMP reaction was positive. As a result, selected LAMP primer set was 100 - 1000 times more specific, rapid, and sensitive than conventional-nested PCR methods. For verification of the developed LAMP assay, twenty samples of cDNA from groundwater samples were tested. We expect that the developed LAMP assay will be used to diagnose HuAstV from various samples.

Development of Loop-mediated Isothermal Amplification (LAMP) for Detection of Vibrio alginolyticus (Loop-mediated isothermal amplification (LAMP)법을 이용한 Vibrio alginolyticus의 신속 진단법 개발)

  • Hong, Seung-hyun;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.903-909
    • /
    • 2015
  • Loop-mediated isothermal amplification (LAMP), a PCR-based diagnostic method, is based on autocycling strand displacement DNA synthesis in the presence of exonuclease-negative Bst DNA polymerase under isothermal conditions. With the help of four specific primers that recognize six different sequences of a target DNA, LAMP has high specificity in pathogenic identification in a short time. Hence, in the present study, LAMP is used as a diagnostic tool in the identification of the most dreadful aquatic pathogenic species, Vibrio alginolyticus, and to develop species-specific LAMP primers and optimization of LAMP reaction conditions such as annealing temperature, elongation time, and other PCR chemical concentrations, including MgSO4, dNTPs, Betaine, and Bst polymerase. The optimized LAMP primers were also checked for specificity with other Vibrio species, which showed that the designed primers were very specific to V. alginolyticus After the first introduction of a species name like this one, the first part (“Vibrio” in this case) should be abbreviated to only the first letter.only. These are usually the most harmful pathogens of the Vibrio species that appear in shrimp and crabs. The results also revealed that the LAMP assay could be 10-fold more sensitive than conventional PCR in detecting V. alginolyticus. This could be the first report on using a rapid and highly sensitive technique, the LAMP assay, in the effective diagnosis of the pathogenic bacteria V. alginolyticus, which could help in the early detection of diseases, particularly in aquaculture.

Development of a Rapid Assay for Peach Rosette Mosaic Virus Using Loop-mediated Isothermal Amplification (Peach rosette mosaic virus 검출을 위한 신속한 등온증폭법 개발)

  • Lee, Siwon;Lee, Jin-Young;Kim, Jin-Ho;Rho, Jae-Young
    • Microbiology and Biotechnology Letters
    • /
    • v.44 no.4
    • /
    • pp.493-496
    • /
    • 2016
  • Peach rosette mosaic virus (PRMV) is a plant virus that was first reported in 1933 by Peach. It can infect hosts including peach, grape, blueberry, dandelion, plum, cherry tree, and weeds. PRMV is non-reportable in Korea, but it is designated as a controlled virus requiring plant quarantine. In this study, for the rapid and specific detection of PRMV, we developed an assay using loop-mediated isothermal amplification (LAMP). Comparison between conventional polymerase chain reaction (PCR) methods (real time-PCR and nested PCR) and LAMP for the detection of PRMV revealed an equivalent level of sensitivity by all the tested methods. For the LAMP assay, outer primer sets were used to amplify a 264-bp PCR product, which was then digested using the restriction enzyme Pvu II (CAG/CTG), and the visualization of two digestion fragments (207 + 57 bp) indicated a positive reaction. The developed LAMP assay for PRMV is expected to enable the rapid monitoring of PRMV in plants.

Simple and Rapid Detection of Potato leafroll virus by Reverse Transcription Loop-mediated Isothermal Amplification

  • Ju, Ho-Jong
    • The Plant Pathology Journal
    • /
    • v.27 no.4
    • /
    • pp.385-389
    • /
    • 2011
  • A new reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the Potato leafroll virus (PLRV) was developed and compared with conventional reverse transcription polymerase chain reaction (RT-PCR) to address its advantages over RTPCR. RT-LAMP primers were designed from the open reading frame 3 (ORF3) sequence of PLRV. The RT-LAMP reactions were conducted without or with a set of loop primers. By real-time monitoring using Turbimeter, the RT-LAMP (with loop primers) detects PLRV in less than 30 min, compared to 120 min of RT-PCR. By adding fluorescent reagent during the reaction, final products of the RT-LAMP were fluorescently visualized under UV light or could be differentiated by naked-eye inspection under normal light. The RT-LAMP was extremely sensitive, about 2000-fold more sensitive than RT-PCR. This study presents great potential of the RT-LAMP for diagnosis and PLRV epidemiology because RT-LAMP method is speedy, sensitive, inexpensive, and convenient.