• Title/Summary/Keyword: LAE

Search Result 1,797, Processing Time 0.039 seconds

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

Optimization of Fermentation Process and Quality Properties of Wild Grape Wine (산머루 와인의 최적 발효조건 및 품질특성)

  • Kim, Eun-Jung;Kim, Yeong-Hoon;Kim, Jong-Won;Lee, Hyo-Hyung;Ko, Yu-Jin;Park, Mi-Hwa;Lee, Jeong-Ok;Kim, Young-Suk;Ha, Yeong-Lae;Ryu, Chung-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.3
    • /
    • pp.366-370
    • /
    • 2007
  • Wild grapes contain various organic acids, vitamins, and inorganic salts compared to other various fruits. Their anthocyanin compounds are also known to have excellent effects in preventing cancers and heart diseases. Wild grapes are supposed to be a superior material for wine fermentation. This study was performed for searching optimum conditions for producing wild grape wines to improve their quality and taste. Four wild strains were isolated from Muscat Bailey A, ‘Kyoho’ grapevine, and wild grapes. For wild grape wine production, an optimum initial sugar concentration was $24^{\circ}Brix$ and an optimum temperature was $24^{\circ}C$. Sensory characteristics of the wild grape wine were evaluated for incense, sour taste, astringency, and sweet taste. Quality properties of the wild grape wine produced under the optimized fermentation conditions were analyzed. Total sugar, polyphenol contents, and acidity of the wild grape wine were 50.00 mg/mL, 25.30 mg/mL, and 0.95%, showing higher value than those of commercial grape wines. Amino acids, tannins, alcohol contents, and pH were 1.80 mg/mL, 1.88 mg/mL, 12%, and 3.59, respectively. The optimum fermentation conditions can be used to improve quality of the wild grape wine.

Changes in Lignan Content and Antioxidant Activity of Fermented Sesame (Sesame indicum L.) by Cultivars (생물전환에 의한 품종별 참깨 발효물의 Lignan 함량과 항산화 활성 변화)

  • Jung, Tae-Dong;Shin, Gi-Hae;Kim, Jae-Min;Oh, Ji-Won;Choi, Sun-Il;Lee, Jin-Ha;Cho, Myoung-Lae;Lee, Sang Jong;Heo, In Young;Park, Seon Ju;Kim, Sung-Up;Jung, Chan-Sik;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.1
    • /
    • pp.143-148
    • /
    • 2016
  • This study investigated the lignan content, total phenol content, and antioxidant activities [2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging and oxygen radical absorbance capacity (ORAC)] of fermented sesame by cultivars. The results showed that the lignan contents of fermented and non-fermented sesame ranged from 2.35~6.58 mg/g and 2.17 to 6.58 mg/g, respectively. The highest total phenol contents of fermented and non-fermented sesame were 51.90 mg gallic acid equivalent (GAE)/g and 25.94 mg GAE/g, respectively. DPPH radical scavenging and ORAC value ranged from 37.95 to 82.57% and from 172.34 to $1,067.80{\mu}M$ TE/g in non-fermented sesame and fermented sesame, respectively. Fermented sesame had higher lignan content, total phenol content and antioxidant activities. than those of non-fermented sesame. Fermented sesame subjected to bioconversion showed increased lignan content and high antioxidant activity.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

The Optimal Configuration of Arch Structures Using Force Approximate Method (부재력(部材力) 근사해법(近似解法)을 이용(利用)한 아치구조물(構造物)의 형상최적화(形狀最適化)에 관한 연구(研究))

  • Lee, Gyu Won;Ro, Min Lae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.95-109
    • /
    • 1993
  • In this study, the optimal configuration of arch structure has been tested by a decomposition technique. The object of this study is to provide the method of optimizing the shapes of both two hinged and fixed arches. The problem of optimal configuration of arch structures includes the interaction formulas, the working stress, and the buckling stress constraints on the assumption that arch ribs can be approximated by a finite number of straight members. On the first level, buckling loads are calculated from the relation of the stiffness matrix and the geometric stiffness matrix by using Rayleigh-Ritz method, and the number of the structural analyses can be decreased by approximating member forces through sensitivity analysis using the design space approach. The objective function is formulated as the total weight of the structures, and the constraints are derived by including the working stress, the buckling stress, and the side limit. On the second level, the nodal point coordinates of the arch structures are used as design variables and the objective function has been taken as the weight function. By treating the nodal point coordinates as design variable, the problem of optimization can be reduced to unconstrained optimal design problem which is easy to solve. Numerical comparisons with results which are obtained from numerical tests for several arch structures with various shapes and constraints show that convergence rate is very fast regardless of constraint types and configuration of arch structures. And the optimal configuration or the arch structures obtained in this study is almost the identical one from other results. The total weight could be decreased by 17.7%-91.7% when an optimal configuration is accomplished.

  • PDF

Reduction of Visceral and Body Fats in Mice by Supplementation of Conjugated Linoleic Acid with γ-Oryzanol (Conjugated linoleic acid와 γ-oryzanol 혼합물의 생쥐 체지방 및 복부지방 감소 효과)

  • Byeon, Jae-Il;Ohr, Tae-Woo;Kim, Young-Suk;Moon, Yeon-Gyu;Park, Cherl-Woo;Kim, Jeong-Ok;Ha, Yeong-Lae
    • Journal of Life Science
    • /
    • v.18 no.9
    • /
    • pp.1212-1218
    • /
    • 2008
  • The synergistic effect of conjugated linoleic acid (CLA) and $\gamma$-oryzanol (OZ) on the reduction of visceral and body fats was investigated in mice. Female ICR mice, 10 weeks of age, were acclimated for one week and then randomly divided into 5 treatment groups by body weights: Control (70 ${\mu}l$ olive oil + 30 ${\mu}l$ CLA), CLA-OZ 1 (70 ${\mu}l$ olive oil + 30 ${\mu}l$ CLA + OZ 0.5 mg), CLA-OZ 2 (70 ${\mu}l$ olive oil + 30 ${\mu}l$ CLA + OZ 1.0 mg), OZ (100 ${\mu}l$ olive oil + OZ 1.0 mg), and Olive oil (100 ${\mu}l$ olive oil). Samples were daily intubated, p.o., for 4 weeks. Food and water were ad libitum. Four weeks later, mice were sacrificed by neck dislocation, followed by measuring whole body weight, empty carcass weight (ECW), which is weight without organs and visceral fats, visceral fats, body fats and protein content. Mice treated with CLA (control) sample maintained significantly, p<0.05, lower whole body weight, ECW, visceral and body fats, relative to mice treated with olive oil sample, indicating that CLA reduces the visceral and body fats. The CLA-OZ 1 treatment significantly reduced, p<0.05, visceral and body fats as compared to OZ treatment, but not significantly different from control treatment.Meanwhile, CLA-OZ 2-treated mice maintained significantly, p<0.05, lower visceral and body fats than control and OZ-treated mice. Protein contents in mice were not affected by any other treatments. These results suggest that OZ enhanced the reduction of visceral and body fats in mice by CLA.

A case-control study on the effects of the genetic polymorphisms of N-acetyltransferase 2 and glutathione S-transferase mu and theta on the risk of bladder cancer (N-Acetyltransferase 2와 glutathione S-transferase mu 및 theta 다형성이 방광암 발생에 미치는 영향에 대한 환자-대조군 연구)

  • Kim, Heon;Kim, Wun-Jae;Lee, Hyung-Lae;Lee, Moo-Song;Kim, Cheol-Hwan;Kim, Ro-Sa;Nan, Hong-Mei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.275-284
    • /
    • 1998
  • Activities of enzymes involved in the metabolism of various carcinogenic xenobiotics is one of the most important host factors for cancer occurrence. N-acetyltransferase (NAT) and glutathione S-transferases (GST) are enzymes which .educe the toxicity of activated carcinogenic metabolites. Slow N-acetylation and lack of GST mu (GSTMI) were reported as risk factors of bladder cancer. GST theta (GSTT1), which is another type of GST, was reported to be deleted at higher proportion among Koreans. Since cause of bladder cancer is not fully explained by single risk factor, many kinds of enzymes would be involved in the metabolism of carcinogens excreted in urine. This study was performed to investigate whether the polymorphisms of NAT2, GSTM1 and GSTT1 are risk factors of bladder cancer and to evaluate the effects of their interaction on bladder cancer development. Sixty-seven bladder cancer and 67 age- and sex-matched non-cancer patients hospitalized in Chungbuk National University Hospital from March to December 1996, are the subjects of this case-control study. Questionnaire interview was done and the genotypes of NAT2, GSTM1 and GSTT1 were identified using PCR methods with DNA extracted from venous blood. The effects of the polymorphism of NAT2 and GSTM1 and their interaction on bladder cancer were statistically tested after controlling the other risk factors. The frequencies of slow, intermediate, and rapid acetylators were 3.0%, 38.8%, and 58.2% to. the cases, and 7.6%, 40.9%, and 51.5% for the controls, respectively. The risk of bladder cancer was not associated with the increase of NAT2 activity($\chi^2_{trend}=1.18$, P-value>0.05). GSTM1 was deleted in 68.7% of the cases and 49.3% of the controls ($\chi^2=5.21$, P-value<0.05), and the odds ratio (95% CI) was 2.23 (1.12 - 4.56). GSTT1 deletion, the .ate of which were 26.9% for the bladder cancer patients and 43.3% for the controls, was a significant protective factor against bladder cancer. Smoking history turned out to be insignificant as a risk factor of bladder cancer (OR=1.85, 95% CI: 0.85 - 4.03), and occupation could not be tested because of the extremely small number of occupational history related to the increase of bladder cancer. In multiple logistic analysis controlling the effects of other risk factors, GSTM1 deletion was the only significant risk factor for bladder cancer (OR: 2.56, 95% CI: 1.22-5.36, P-value<0.05), but slow acetylation and GSTT1 deletion were not. These results suggest that GSTM1 deletion may be a significant risk factor of bladder cancer. Since there have been much debates on causal relationship between slow acetylation and GSTT1 deletion, and bladder cancer, further studies are needed.

  • PDF