• Title/Summary/Keyword: L4

Search Result 40,688, Processing Time 0.077 seconds

Inhibitory Effects on the Enzymes Involved in the Inflammation by the Ethanol Extracts of Plant Foodstuffs (식물성 일반식품 자원의 에탄올 추출물이 염증 효소계에 미치는 영향)

  • Kwon, Eun-Sook;Kim, Il-Rang;Kwon, Hoon-Jeong
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.348-352
    • /
    • 2007
  • Inflammation is a complex process resulting from a variety of mechanisms. Combined inhibition of the activities of enzymes involved in the process may therefore be considered more important in anti-inflammatory property of plant extracts than any single contribution. In this study, the inhibitory effects of the ethanol extracts of thirty plant foods on the activities of secretory phospholipase $A_{2}$ ($sPLA_{2}$), cyclooxygenase-1 (COX-1), cyclooxygenase-2 (COX-2), and 12-lipoxygenase (12-LOX) were examined. Several legumes, mungbean sprout and some leaf vegetables inhibited the activity of $sPLA_2$, upstream enzyme of inflammation pathway. Only soybean sprout and mungbean sprout significantly inhibited 12-LOX activity. Although most of extracts inhibited the activities of both COX-1 and COX-2, water dropwort and amaranth showed selectivity for the inhibition of COX-2 over COX-1. Especially, mungbean showed anti-inflammatory property at both upstream and downstream of inflammation pathway with relatively low $IC_{50}$ values for $sPLA_{2}$ and COX-2 enzymes. Mungbean sprout exhibited inhibitory effects on all enzymes related to early and late inflammation and soybean sprout suppressed 12-LOX and COX-2 simultaneously, although the activities of these plants were showed at relatively high concentration. Therefore, mungbean, mungbean sprout, and soybean sprout appear to exhibit anti-inflammatory effects by combined inhibition of inflammatory enzymes.

A Study on Reading Pupillary and Distance Between Optical Centers suitable for Korean (한국인 체형에 적합한 근용안경의 광학중심간 거리에 대한 연구)

  • Youk, Do-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.37-45
    • /
    • 2003
  • This study investigated that total 1071 reading glasses wearers (male 432, female 639) without any eye disease or deformation in eyelid, orbit, eyeball (over 50 years old), were tested. Reading pupillary distance of 524 (male 202, female 322) of 1071 were examined and reading glasses power was examined for all 1071 patients. As a result of average reading diopters analysis by sex. male had S+2.34Dptr, female had S+2.23Dptr in average and male had a little more average power than female by 0.11Dptr. However, the difference was not much enough and by aging accommodation reduction changes were applied to both male and female. After dividing ready-made reading glasses on sale in optical shops into 5 groups by F.P.D. the average D.B.O.C(distance between optical centers) of each 5 group was examined (1st group 64.04 mm, 2nd group 66.96 mm, 3rd group 68.28 mm, 1th group 62.03 mm, 5th group 72.00 mm : the average of all groups was 66.96 mm : each group included 3 random samples : 195 ready-made reading glasses were measured), and compared with the average reading P.D of males and females (male 60.04 mm, female 58.23 mm). The result showed D.B.O.C of ready-made reading glasses on sale was bigger than the average reading P.D of them. The result reviewed the average range for male was $0.23{\Delta}(minimum){\sim}5.06{\Delta}(maximum)$, and for female was $0.46{\Delta}{\sim}5.79{\Delta}$. In conclusion when wearing ready-made reading glasses, female got more effected by average $0.45{\Delta}$ because reading P.D of female was smaller than that of male.

  • PDF

Development of pSJE6c, an Expression Vector for Kimchi Lactic Acid Bacteria, and Heterologous Gene Expression Using the Vector (김치유산균용 발현벡터 pSJE6c 개발과 이를 이용한 외래 유전자 발현)

  • Lee, Kang-Wook;Park, Ji-Yeong;Lee, Ji-Yeon;Lee, Hwang-A;Baek, Chang-Un;Jo, Hyeon-Deok;Kim, Joo-Yeon;Kwon, Gun-Hee;Chun, Ji_Yeon;Kim, Jeong-Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.4
    • /
    • pp.389-398
    • /
    • 2009
  • Development of expression vectors is important for the basic and applied researches on kimchi LAB (lactic acid bacteria). An expression vector, pSJE6c was constructed by inserting P6C promoter sequence from Lactococcus lactis into pSJE, a shuttle vector for E. coli and Leuconostoc species. To test the efficiency of pSJE6c, aga ($\alpha$-galactosidase) and lacZ ($\beta$-galactosidase) genes were expressed in Lactobacillus brevis 2.14. Compared to the pSJE, expression levels of both genes were increased, indicating P6C promoter was better than indigenous promoters. Enzyme activities of L. brevis cells harboring pSJE6caga (pSJE6c with aga) or pSJE6Z (pSJE6c with lacZ) were 1.5-2 fold higher than those with pSJEaga (pSJE with aga) or pSJEZ (pSJE with lacZ). More RNA transcripts were detected in cells harboring pSJE6c based recombinant plasmid. The results indicated that heterologous gene expressions in kimchi LAB could be improved significantly by use of efficient expression vectors.

Quality Analysis on the Size and the Preparation Method of Meju for the Preparation of Korean Traditional Soy Sauce (Kanjang) (한국 재래식 간장 제조를 위한 메주의 크기와 제조 방법에 따른 품질특성)

  • Lee, Jong-Gu;Kwon, Kwang-Il;Choung, Myoung-Gun;Kwon, O-Jun;Choi, Ji-Young;Im, Moo-Hyeog
    • Journal of Applied Biological Chemistry
    • /
    • v.52 no.4
    • /
    • pp.205-211
    • /
    • 2009
  • This study was carried out to acquire basic data for industrial production of Korean traditional kanjang (soy sauce). Five types of meju, $23{\times}11{\times}12$ ($L{\times}W{\times}H$, cm), $23{\times}11{\times}7$, $15{\times}11{\times}7$, $11{\times}11{\times}6$, $11{\times}11{\times}6$ (made a hole $\varphi$ 1.5 cm) were prepared. The temperature and humidity of meju preparation were $15{\sim}20^{\circ}C$ and 40~50% respectively. The smaller size of meju, the lower free amino acid and non-volatile organic acid content of that. And, two types of meju, conventional method (CM-meju, the temperature and humidity were prepared at $15{\sim}20^{\circ}C$ and 40~50% of relative humidity) and improved method(IM-meju, the temperature and humidity were prepared at $25{\sim}30^{\circ}C$ and 80~90% of relative humidity) for kanjang production were prepared. There was no difference of total nitrogen content and soluble nitrogen content in the size of meju. In total free amino acid content and total free sugar content, IM-meju was the higher than CM-meju. So, the quality of IM-meju was better than that of CM-meju.

Diagnosis of Irrigation Time Based on Microchange of Stem Diameter in Greenhouse Tomato (온실재배 토마토의 농직경 변화에 의한 관개시기 진단)

  • 이변우
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.250-257
    • /
    • 1997
  • Stem diameter and shoot fresh weight of tomato grown in greenhouse were measured non-destructively at 10 minutes interval from 1 to 16 July, 1996 with displacement detector using strain gauges and with suspension-type load cell, respectively, and simultaneously were measured soil water potential, transpiration and solar radiation. Ample water was irrigated before experiment, and thereafter, irrigations were made on the next morning when visual symptoms of wilting appeared. Shoot fresh weight and stem diameter showed very similar patterns in diurnal changes which are characterized by predawn maximum and afternoon minimum and in long- term evolutions, suggesting that stem diameter shrinkage and expansion are closely related to plant water content and growth, respectively, Shoot weight and stem diameter reached minimum values a little later than the time on which transpiration showed maximum. The daily net gains of fresh weight(DG) and stem diameter(DI) showed significantly Positive correlations with solar radiation in those days on which plants were not water-stressed. However, Dl and DG on those days of water stress showed much lower values than expected from the relationships between solar radiation and them. Transpiration was much lower than the expected potential transpiration on 10 July, implying that plants were water-stressed. In this case water stress was not detected from visual symptom of wilting and/or soil water potential, but was able to be identified by the lower DI and DG than the expected. The maximum contraction of stem diameter(MC) and the maximum loss of fresh weight(ML) during daytime showed significantly positive correlations with solar radiation in those days on which plants were not water-stressed and were observed greater than expected from the relationships on severely water-stressed days. But mild water stress could not be discernable by ML and MC. It would be concluded that the daily net gains of fresh weight and/or stem diameter could be used as criteria for diagnosing the water status of tomato and for triggoring the onset of irrigation in automatic system.

  • PDF

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

Effects of Zinc, Phosphorus and Iron on the Cadmium Uptake and Accumulation by Hydroponically Grown Tomato (수경 재배된 도마도(Lycopersicum esculentum Mill)에 의한 Cd의 흡수, 축적과 이에 미치는 Zn, Fe 및 인산의 효과)

  • Kim, M.J.;Motto, H.L.
    • Applied Biological Chemistry
    • /
    • v.21 no.1
    • /
    • pp.40-50
    • /
    • 1978
  • Effects of Zn, P and Fe on Cd uptake and accumulations by tomato (Lycopersicum esculentum Mill) and also their interactions on the uptake of Zn, Fe, Mn, P and Cd were investigated using batch type solution culture technique. Experiment 1 was a factorial scheme with 3 levels of Zn (0, 0.5, 2.5 ppm) and 3 levels of Cd (0, 0.2, 1.0 ppm). At 1.0 ppm Cd, significant yield reduction of dry matter and visual toxicity symptoms (yellowing and necrosis) of Cd was observed for all zinc levels. At this Cd level, increasing Zn treatment from 0 to 2.5 ppm increased Cd concentration from 199 to 235 ppm in leaves and from 124 to 145 ppm in stems. Similarly, Cd treatment did not suppress Zn uptake in leaves, and rather significantly increased in stems. Fe concentrations in leaves and stems were significantly reduced due to Cd treatment while Mn were increased by both Zn and Cd treatment. The results of experiment 2 with 3 levels of P (0.5, 2.0, 4.0m Mol) and 3 levels of Cd (0, 1.0, 2.0 ppm) in a factorial scheme also showed a growth reduction and visual toxic symptons from 1.0 ppm Cd level. Increasing P treatment tend to increase Cd concentrations in leaves and stems although it was not statistically significant. Increasing P concentration due to Cd treatment could be the 'concentration' effect as a result of reduced growth, while there was significant decrease in Fe concentration due to Cd treatment in spite of possible 'concentration' effect. Mn concentration was increased at 1.0 ppm Cd level and then dropped at 2.0 ppm Cd level. Zu concentration in leaves and stems showed significant increase as Cd treatment increased as observed in experiment 1. Experiment 3 had 3 levels of Fe (0.5, 1.0, 2.0 ppm) and 3 levels of Cd (0, 0.8, 1.6 ppm) treatments in a factorial design. Significant growth reduction and visual toxic symptoms as observed in experiment 1 and 2 were also observed from 0.8 ppm Cd level. Increasing Fe treatment obviously alleviated toxic symptoms, improved growth and significantly increased dry matter yield. At 0.8 ppm Cd treatment level, increasing Fe treatment from 0.5 to 2.0 ppm significantly decreased Cd concentration from 141 to 92 ppm in leaves and from 101 to 46 ppm in stems. At 1.6 ppm Cd treatment level the decrease was from 224 to 167 ppm in leaves and from 124 to 109 ppm in stems. As in the case of experiment 1 and 2, Fe concentration in leaves and stems were reduced as Cd treatment increased to 1.6 ppm at 0.5 and 1. 0 Fe treatment levels, whereas at 2.0 ppm Fe level, Cd treatment increased Fe concentration in leaves and stems showing significant interactions of Fe and Cd on Fe uptake. Cd effect on Zn and Mn showed similar results to experiment 1 and 2 and Fe treatments reduced Zn and Mn concentrations in plant tissue. The results of 3 experiments show that P and Zn did not manifest suppressive effect on Cd uptake, Fe significantly demonstrated it. Fe also alleviated Cd toxicity symptoms significantly in terms of visual symptoms and dry matter yield. Visual toxicity symptoms were definitely related to Fe status in plant tissue as well as possible physiological effect of Cd itself, and the results suggest that Fe requirement for normal growth increase as Cd element is present in plant tissue. Zn accumulated more in stems than in leaves whereas Cd, Fe and Mn showed the opposite trend in all experiments.

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

The Etiologic Diseases and Diagnostic Usefulness of Color Doppler Ultrasonography in Children with Chronic Coughs (소아 만성 기침의 원인 질환과 컬러 도플러 초음파 검사의 진단적 유용성)

  • Park, Sun Young;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • Purpose : The objectives of this study were to investigate the causes of chronic cough and to establish the appropriate diagnostic approach to chronic cough in children. Methods : One hundred and thirty two cases of chronic cough were prospectively evaluated. They visitors to pediatric chronic cough clinics at Kang-nam saint Mary's Hospital of Catholic University from August 2000 to July 2001 for 12 months. Careful history taking by questionnaire, physical examination, radiologic studies of chest and sinus, hematologic and immunologic studies, allergic skin tests, and methacholine challenge tests were performed. Color doppler(CD) ultrasonography were performed and compared with simultaneous 24 Hr. esophageal pH monitoring to diagnose gastroesophageal reflux disease(GERD). Results : Age distributions were demonstrated that nine in infants, 82 in early childhood, 38 in late childhood, and three in adolescence. Common causes of chronic cough were bronchial asthma in 40 cases, chronic sinusitis in 22 cases, GERD in seven cases, bronchial asthma combined with sinusitis in 28 cases, bronchial asthma combined with GERD in 14 cases, psychogenic cough in two. cases, foreign body in one case, chronic bronchitis in one case, and bronchiolitis in one case. Comparing with 24 Hr. pH monitoring, sensitivity, specificity, positive predictive value and negative predictive values of CD ultrasonography were 88%, 69%, 85 %, and 73% respectively. Conclusion : The most common causes of chronic cough in children were bronchial asthma, sinusitis and GERD in order. We suggest that CD ultrasonography can be used as a good, convenient screening method for patients with suspected GERD in outpatient settings.

Pharmacokinetic Study of Pyrazinamide Related to the Mechanism of the Renal Excretion (Pyrazinamide의 신배설기전에 관한 약동학적 연구)

  • Choi, Eung-Sang;Shin, Sang-Goo;Lee, Sun-Hee;Choi, Cheol-Hee;Kim, Yong-Sik;Lim, Jung-Kyoo;Park, Chan-Woong
    • The Korean Journal of Pharmacology
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 1987
  • The renal handling and tissue distribution of pyrazinamide were studied after administration of single dose intravenous injection for 15 min or constant infusion in New Zealand White rabbits. Peak pyrazinamide serum concentration ranged from 57.3 to $105.0{\mu}g/ml$ ($mean{\pm}SD;83.0{\pm}17.8$). The mean half-life of the a phase was $0.143{\pm}0.047$ hr while the ${\beta}$ phase ranged from 1.66 to 3.25 hr($mean{\pm}SD;2.38{\pm}0.57$). The mean steady-state volume of distribution in non-compartmental model was $0.935{\pm}0.362\;L/kg$ Excretion ratio of pyrazinamide was dramatically reduced from 1.02 to 0.30 when unbound serum pyrazinamide concentration was increased from 6.04 to $60.9\;{\mu}g/ml$. The urine flow dependency of renal clearance of pyrazinamide was demonstrated in steady-state serum concentration. The tissue/serum concentration ratio of pyrazinamide was highest in kidney and lowest in skeletal muscle among the tissues examined. The results suggested that a large fraction of pyrazinamide filtered by glomerulus and secreted by renal tubule was reabsorbed and this tubular reabsorption of pyrazinamide might be greatly influenced by urine flow.

  • PDF