• Title/Summary/Keyword: L2TP

Search Result 421, Processing Time 0.024 seconds

DISTRIBUTION OF ORGANIC MATTERS AND RELEASE CHARACTERISTICS IN DAM RESERVOIR

  • Lee, Yo-Sang;Kim, Woo-Gu;Koh, Deuk-Koo;Yang, Jae-Rheen
    • Water for future
    • /
    • v.35 no.5
    • /
    • pp.21-30
    • /
    • 2002
  • The inflow into a multi-purpose dam reservoir contains many suspended solids from the upper stream during the rainy season. Concentrations of SS increased to 73.3 mg/l and the TP measurement increased to 0.09 mg/l during the rainy season in 1999. It was discovered that particles less than $10\;\mu\textrm{m}$ in size composed about 50% of the total amount. Some of these particles reduce the reservoir capacity and have an impact on water. In this study, the sediment depth at Daecheong multi-purpose dam was examined. Piston coring was performed at 9 locations At Hoenam 1 out of 9 locations examined showed maximum depth, which was 90 cm and at Muneui 3 showed the minimum depth, which was 35 cm. At Hoenam, the release rate of TN was found to be $62.14~84.72\;mg/\textrm{m}^2{\cdot}day$ in 1998. However, it was found to considerably reduced to $23.20\;mg/\textrm{m}^2{\cdot}day$ in 2001. The release rate of TP was measured at $13.02~14.38\;mg/\textrm{m}^2$.day at 1998, and it was reduced to $6.93mg/\;mg/\textrm{m}^2{\cdot}day$ in 2001.

  • PDF

Microalgal Growth and Nutrient Removal in a Lake, a Stream and the Outflow of a Wastewater Treatment System (호수수, 하천수와 하수처리수에서 미세조류 증식 특성 및 영양 염류 제거 효과)

  • Chang, In-Ho;Joung, Yo-Chan;Choi, Seung-Ik;Ahn, Tae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.2
    • /
    • pp.129-135
    • /
    • 2011
  • The possibility of nutrient removal during Scenedesmus sp. growth in Lake Paldang, Geongan cheon stream, and the outflow from a wastewater treatment system was examined. Scenedesmus sp. grew well in Lake Paldang water when total nitrogen (TN) and total phosphorus (TP) values were 1.9 and 0.02 mg $L^{-1}$, respectively, and 50% of the nutrients were removed. In Geongan cheon stream, the TN and TP was 3.0 mg $L^{-1}$ and 0.09 mg $L^{-1}$, respectively, chlorophyll-${\alpha}$ reached a maximum of 239~259 $m^{-3}$, and 50% of the nutrients were removed. In the wastewater treatment outflow, where Scenedesmus sp. already existed, the organism grew well without inoculation. Scenedesmus sp. can grow with proper inoculation and physical turbulence in natural waters, such as lake and stream water, and nutrients can be eliminated as phytoplankton growth occurs.

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Effect of Operating Parameters on the Phosphorus Removal of Municipal Wastewater in a Pilot-scale Moving Bed Biofilm Reactor with Waste-tire Media (폐타이어 담체를 이용한 파일럿 규모 유동상 생물막 공정에서 하수의 인제거에 미치는 운전인자 영향)

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.436-441
    • /
    • 2008
  • This work experimentally determined the effect of operating parameters such as temperature and solid retention time (SRT) on the phosphorus removal of municipal wastewater with waste-tire media. The experiments were carried out in pilot-scale moving bed biofilm reactor filled at a 0.15 filling ratio with the media. Total phosphorus (TP) removal efficiency was $91{\pm}5$, $75{\pm}16$, and $59{\pm}14%$ at the temperature of 9~10, 10~20, and $20{\sim}26^{\circ}C$, respectively. TP removal efficiency was $71{\pm}17$, $74{\pm}16$, $74{\pm}16$, and $68{\pm}18%$ at the SRT of 3.5~5, 5~10, 10~15, and 15~20 days, respectively. At the nitrate concentration of 1~3, 3~6, and 6~9 mg/L, TP removal efficiency was $82{\pm}9$, $68{\pm}18$, $47{\pm}7%$, respectively. The concentration of total phosphorus in the effluent was $0.1{\sim}1.8(0.8{\pm}0.4)mg/L$ regardless of operating conditions, which meets Korean phosphorus limit value, 2 mg/L, for discharge into receiving waters.

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

The effect of powder A2/powder A3 mixing ratio on color and translucency parameters of dental porcelain

  • Lee, Wan-Sun;Kim, So-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.400-405
    • /
    • 2015
  • PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, $L^*$, $a^*$, and $b^*$ were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (${\alpha}$=0.05). RESULTS. The higher the mixing ratio was, $L^*$, $a^*$, and $b^*$ of IPS e.max Ceram were all increased, and $L^*$ of Vintage Halo was reduced and $a^*$ and $b^*$ were increased. $L^*$ and $a^*$ of Ceramco3 were reduced and $b^*$ of Ceramco3 was increased. Color difference (${\Delta}E^*ab$) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE $L^*$, $a^*$, and $b^*$ were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

A study on the derivation of Dimensionless Unit Hydrographs by the Linear model in the small watersheds (선형 Model에 의한 소류역에 있어서의 무차원 단위도 유도에 관한 연구)

  • 이순혁;한중석
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.23 no.3
    • /
    • pp.78-87
    • /
    • 1981
  • This study was attempted to get dimensionless unit hydrograph by linear model which can be used to the estimation of flood for the development of Agricultural water resources and laid emphasis on the application of dimensionless unit hydrographs for the ungaged watersheds by applying linear model. The results summarized through this study are as follows. 1.Peak discharge is found to be Qp= CAR (C =0. 895A-o.145) having high significance between peak discharge, Qp and effective rainfall, R within the range of small watershed area, 84 to 470km2. consequently, linearity was acknowledged between rainfall and runoff. Reasonability is confirmed for the derivation of dimensionless unit hydrograph by linear model. 2.Through mathematical analysis, formula for the derivation of dimensionless unit hydrograph was derived. qp--p=(tp--t)n-1[e-(n-1)](tp--t-1) 3.Moment method was used for the evaluation of storage constant, K and shape parameter, n for the derivation of dimensionless unit hydrograph. Storage constant, K is more closely related with the such watershed characteristics as length of main stream and slopes. On the other hand, the shape parameter, n was derived with such watershed characteristics as watershed area, river length, centroid distance of the basin and slopes. 4.Time to peak discharge, Tp could be expressed as Tp=1. 25 (√s/L)0.76 having a high significance. 5.Dimensionless unit hydrographs by linear model stood more closely to the observe dimensionless unit hydrographs On the contrary, dimensionless unit hydrographs by S.C. S. method has much difference in comparison with linear model at the falling limb of hydrographs. 6.Relative errors in the q/qp at the point of 0.8 and 1.2 for the dimensionles ratio by linear model and S. C. S. method showed to be 2.41, 1.57 and 4.0, 3.19 percent respectively to the q/qp of observed dimensionless unit hydrographs. 7.Derivation of dimensionless unit hydrograph by linear model can be accomplished by linking the two empirical formulars for storage constant, K, and shape parameter, n with derivation formular for dimensionless unit hydrograph for the ungaged small watersheds.

  • PDF

Nutrient Balance in the Paddy Fields Watershed with a Source of River Water (하천관개지역 광역논에서의 영양물질의 물질수지)

  • Lee, Jeong Beom;Lee, Jae Yong;Li, Si Hong;Jang, Jeong Ryeol;Jang, Ik Geun;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.

Determination of Pollutant EMCs and Loadings of Runoff in Paved Areas (포장지역내 강우유출수의 EMCs 및 부하량 산정)

  • Gil, Kyung-Ik;Wee, Seung-Kyung;Park, Moo-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.119-122
    • /
    • 2008
  • The paved area like a road or bridge where having high impermeable rates were accumulated various non-point sources(NPS) by passing vehicles during dry season periods. They are flowed in the river continuous when it rains and could negative impact on environment. Therefore, this study monitoring NPS for two years and determinating for each pollutant EMCs and mass loading. The result shows that the EMC ranges are 11.60$\sim$230.90 mg/L for TSS, 4.58$\sim$31.90 mg/L for BOD, 1.86$\sim$9.20 mg/L for TN and 0.14$\sim$1.55 mg/L for TP. Also, the ranges of washed-off mass loading are determined to 0.78$\sim$18.01 kg/day for TSS, 0.47$\sim$1.17 kg/day for BOD, 0.00$\sim$0.01 kg/day for Pb and 0.01$\sim$0.06 kg/day for Zn.

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.