• Title/Summary/Keyword: L2TP

Search Result 421, Processing Time 0.027 seconds

An Estimation Study of Watershed Pollution Load Reduction Using Environmental Capacity (환경용량을 고려한 유역 오염부하삭감량 추정 연구)

  • Jung, Jae-Sung;Park, Young-Ki;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1265-1273
    • /
    • 2006
  • The environmental capacity and watershed pollution load reduction of Yongdam reservoir were estimated by the simulation of water quality variation process with the target water quality establishment, pollution load estimation and flow analysis. The potable raw water $I{\sim}II$, COD $1.0{\sim}3.0$ mg/L and TP $0.01{\sim}0.03$ mg/L were selected as the target water quality Yongdam reservoir water quality model was constructed with WASP5 contained 42 segments and the correlation of calibrated results were BOD 0.73, $PO_4-P$ 0.98. The environmental capacity for target quality COD 2.0 mg/L and TP 0.02 mg/L were BOD $131,880{\sim}4,694$ kg/d, TP $7,855 {\sim}167$ kg/d which were less than exists, and the related reduction ratios were BOD $51{\sim}62%$, TP $47{\sim}67%$ which were middle amount in exists. The load reduction ratios to meet the potable raw water $I{\sim}II$ were BOD $72{\sim}16%$, TP $78{\sim}36%$ in existing conditions and BOD $81{\sim}44%$, TP $84{\sim}52%$ in new conditions. BOD was the least one and TP was the second least in 4 results. The effects of the load reduction assignment to subbasin were dominant in TP but little in COD.

Correlation of the Beta-Trace Protein and Inflammatory Cytokines with Magnetic Resonance Imaging in Chronic Subdural Hematomas : A Prospective Study

  • Park, Ki-Su;Park, Seong-Hyun;Hwang, Sung-Kyoo;Kim, Chaekyung;Hwang, Jeong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.235-241
    • /
    • 2015
  • Objective : Magnetic resonance imaging (MRI) of chronic subdural hematoma (CSDH) detects various patterns, which can be attributed to many factors. The purpose of this study was to measure the level of interleukin-6 (IL-6), interleukin-8 (IL-8), and highly specific protein [beta-trace protein (${\beta}TP$)] for cerebrospinal fluid (CSF) in CSDHs, and correlate the levels of these markers with the MRI findings. Methods : Thirty one patients, treated surgically for CSDH, were divided on the basis of MRI findings into hyperintense and non-hyperintense groups. The concentrations of IL-6, IL-8, and ${\beta}TP$ in the subdural fluid and serum were measured. The ${\beta}TP$ was considered to indicate an admixture of CSF to the subdural fluid if ${\beta}TP$ in the subdural fluid $({\beta}TP_{SF})/{\beta}TP$ in the serum $({\beta}TP_{SER})>2$. Results : The mean concentrations of IL-6 and IL-8 of the hyperintense group (n=17) of T1-WI MRI were $3975.1{\pm}1040.8pg/mL$ and $6873.2{\pm}6365.4pg/mL$, whereas them of the non-hyperintense group (n=14) were $2173.5{\pm}1042.1pg/mL$ and $2851.2{\pm}6267.5pg/mL$ (p<0.001 and p=0.004). The mean concentrations of ${\beta}TP_{SF}$ and the ratio of ${\beta}TP_{SF}/{\beta}TP_{SER}$ of the hyperintense group (n=13) of T2-WI MRI were $7.3{\pm}2.9mg/L$ and $12.6{\pm}5.4$, whereas them of the non-hyperintense group (n=18) were $4.3{\pm}2.3mg/L$ and $7.5{\pm}3.9$ (p=0.011 and p=0.011). Conclusion : The hyperintense group on T1-WI MRI of CSDHs exhibited higher concentrations of IL-6 and IL-8 than non-hyperintense group. And, the hyperintese group on T2-WI MRI exhibited higher concentrations of ${\beta}TP_{SF}$ and the ratio of ${\beta}TP_{SF}/{\beta}TP_{SER}$ than non-hyperintense group. These findings appear to be associated with rebleeding and CSF admixture in the CSDHs.

An Implementation of Layer Two Tunneling Protocol (L2TP) for VPN Service (VPN 서비스를 위한 Layer Two Tunneling Protocol (L2TP)의 구현)

  • 정미라;최종원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.569-571
    • /
    • 1999
  • 최근 이동 사용자가 늘어나고 기업간의 사내망 구축이 증가하면서 Virtual Private Network(VPN) 서비스에 대한 요구가 많아지게 되었다. VPN 서비스를 위한 표준으로 제안된 L2TP는 PPTP.L2F와 호환이 가능하며, IPx, Appletalk 등 다중 프로토콜 지원이 가능하다는 장점을 가진다. L2TP는 다중 터널, 다중 세션을 지원하며 터널의 보안을 위해 터널 인증 시 CHAP과 유사한 기법으로 상대 시스템 인증이 가능하고 제어 메시지 암호화와 같은 기능을 통해 외부의 침입자로부터 터널을 안전하게 보호한다. 또한 확장성을 위해 제어 메시지에 사용되는 속성 값들을 각각의 고유한 속성과 그 값들의 가변적인 집합으로 구성하여 전송하는 기법을 사용하고 있다. 본 논문에서는 LSTP의 특징을 다른 터널링 프로토콜들과 비교, 분석하고 주요 기능을 구현하는 것을 주목적으로 한다.

  • PDF

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

Analysis of Secure Remote Access to Virtual Private Home Network with L2TP Tunneling methods (L2TP tunneling 방법을 기반으로 한 가설 사설망의 보안 원격 접속분석)

  • Basukala, Roja Kiran;Choi, Dong-You;Han, Seung-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2188-2194
    • /
    • 2008
  • Home network is the connection and communication of several electronic and electrical devices at hone with the integration of several technologies like Ethernet, wireless, phone line and power-line at the residential gateway to the internet. This internet based home network can be accessed from any part of the world through any device by any poison via internet. Since home network is developed for comfortable and safe life of home users, the information flow to/from home network needs to be private. Hence the remote access of the home network must be secured. This paper analyses two secure tunneling methods, voluntary and compulsory for L2TP(Layer Two Tunneling Protocol) based VPN(Virtual Private Network) for secure remote access of the home network.

Spatio-temporal Fluctuations with Influences of Inflowing Tributary Streams on Water Quality in Daecheong Reservoir (대청호의 시공간적 수질 변화 특성 및 호수내 유입지천의 영향)

  • Kim, Gyung-Hyun;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.158-173
    • /
    • 2012
  • The objectives of this study were to analyze the longitudinal gradient and temporal variations of water quality in Daecheong Reservoir in relation to the major inflowing streams from the watershed, during 2001~2010. For the study, we selected 7 main-stream sites of the reservoir along the main axis of the reservoir, from the headwater to the dam and 8 tributary streams. In-reservoir nutrients of TN and TP showed longitudinal declines from the headwater to the dam, which results in a distinct zonation of the riverine ($R_z$, M1~M3), transition ($T_z$, M4~M6), and lacustrine zone ($L_z$, M7) in water quality, as shown in other foreign reservoirs. Chlorophyll-a (CHL) and BOD as an indicator of organic matter, were maximum in the $T_z$. Concentration of total phosphorus (TP) was the highest (8.52 $mg\;L^{-1}$) on March in the $R_z$, and was the highest (165 ${\mu}g\;L^{-1}$) in the $L_z$ on July. Values of TN was the maximum (377 ${\mu}g\;L^{-1}$) on August in the $R_z$, and was the highest (3.76 $mg\;L^{-1}$) in the $L_z$ on August. Ionic dilution was evident during September~October, after the monsoon rain. The mean ratios of TN : TP, as an indicator of limiting factor, were 88, which indicates that nitrogen is a surplus for phytoplankton growth in this system. Nutrient analysis of inflowing streams showed that major nutrient sources were headwater streams of T1~T2 and Ockcheon-Stream of T5, and the most influential inflowing stream to the reservoir was T5, which is located in the mid-reservoir, and is directly influenced by the waste-water treatment plants. The key parameters, influenced by the monsoon rain, were TP and suspended solids (SS). Empirical models of trophic variables indicated that variations of CHL in the $R_z$ ($R^2$=0.044, p=0.264) and $T_z$ ($R^2$=0.126, p=0.054) were not accounted by TN, but were significant (p=0.032) in the $L_z$. The variation of the log-transformed $I_r$-CHL was not accounted ($R^2$=0.258, p=0.110) by $I_w$-TN of inflowing streams, but was determined ($R^2$=0.567, p=0.005) by $I_w$-TP of inflowing streams. In other words, TP inputs from the inflowing streams were the major determinants on the in-reservoir phytoplankton growth. Regression analysis of TN : TP suggested that the ratio was determined by P, rather than N. Overall, our data suggest that TP and suspended solids, during the summer flood period, should be reduced from the eutrophication control and P-input from Ockcheon-Stream should be controlled for water quality improvement.

Availability of Land Surface Temperature Using Landsat 8 OLI/TIRS Science Products (Landsat 8 OLI/TIRS Science Product를 활용한 지표면 온도 유용성 평가)

  • Park, SeongWook;Kim, MinSik
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.463-473
    • /
    • 2021
  • Recently, United States Geological Survey (USGS) distributed Landsat 8 Collection 2 Level 2 Science Product (L2SP). This paper aims to derive land surface temperature from L2SP and to validate it. Validation is made by comparing the land surface temperature with the one calculated from Landsat 8 Collection 1 Level 1 Terrain Precision (L1TP) and the one from Automated Synoptic Observing System (ASOS). L2SP is calculated from Landsat 8 Collection 2 Level 1 data and it provides land surface temperature to users without processing surface reflectance data. Landsat 8 data from 2018 to 2020 is collected and ground sensor data from eight sites of ASOS are used to evaluate L2SP land surface temperature data. To compare ground sensor data with remotely sensed data, 3×3 grid area data near ASOS station is used. As a result of analysis with ASOS data, L2SP and L1TP land surface temperature shows Pearson correlation coefficient of 0.971 and 0.964, respectively. RMSE (Root Mean Square Error) of two results with ASOS data is 4.029℃, 5.247℃ respectively. This result suggests that L2SP data is more adequate to acquire land surface temperature than L1TP. If seasonal difference and geometric features such as slope are considered, the result would improve.

Application Study of small-scale sewage treatment system with A2/O precess in Mongolia (A2/O 공법을 이용한 소규모 하수처리시스템의 몽골 현지 적용에 관한 연구)

  • Yeo, Yeongki;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.431-440
    • /
    • 2017
  • The small-scale sewage treatement system with $A^2/O$ process was applied to evaluate applicability for Mongolian sewage, It was designed to have 10 m3/d flowrate and installed in Ulaanbaatar, Mongolia. During over 6month operation BOD, COD, TN, TP removal efficiency were measured and operation condition was optimized. In addition, MLSS concentration its internal circulation rate and DO were adjusted properly. BOD, COD showed average 88 perecent of removal and TN and TP achieved 81 percent and 88 percent removal efficency, respectively. Maxium influent concentration of BOD, COD, TN and TP was 214 mg/L, 300 mg/L, 24.3 mg/L and 5 mg/L respectively, which were decreased to 4.1 mg/L, 5.6 mg/L, 1.3 mg/L and 0.15 mg/L by the test system. This study show possibility tham small-scale sewage treatment system could be a useful system for scattered sewage wastewater treatment.

A Study on the Establishment and Achievement of Target Water Quality by Water System of Major Streams in the Gangwon Province (강원도내 주요하천 수계별 목표수질 설정 및 달성도 연구)

  • Huh, In-Ryang;Choi, Ji-Yong;Kim, Yeong-Jin;Kim, Sung-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.424-430
    • /
    • 2006
  • Since 1985, the Gangwon Institute of Health and Environment(GIHE) and Ministry of Environment have collected rivers and streams water quality data in an ambient surface water monitering program. This study was prepared to propose an achievement of water quality of rivers subject to management by area according to an created level while establishing a water quality level applicable to the Gangwon area. As a result of evaluating correlativity on the BOD-based water quality data, BOD versus TP, and TP versus SS demonstrated significance at a confidence level of 95%. Evaluating correlativity on $10{\sim}90$ percentile values of analyzed data, a coefficient of determination, $r^{2}$ of BOD versus TP, and TP versus SS were 0.625, 0.286 respectively. Grading the results by evaluation method, the representative values of TP were 0.030 mg/l for I level, 0.100 mg/l for II level, 0.200 mg/l for Ill level, 0.300 mg/l for IV level, and 0.350 mg/l for V level, and those of SS were indicated 4.0 mg/l for I level, 15.0 mg/l for II level, 30.0 mg/l for III level, 45.0 mg/l for IV level, and 60.0 mg/l for V level. As for the limiting factor allowing the water quality standard exceeded, BOD posted 61% as the factor was found in 11 places, TP 28%, and SS 33%.