• Title/Summary/Keyword: Korean utility helicopter

Search Result 42, Processing Time 0.019 seconds

A Study of Fatigue Load for Rotor Blades of the Utility Helicopter (다목적 헬리콥터 로터 블레이드 피로하중에 대한 연구)

  • Oh, Man-Seok;Kim, Hyun-Duk;Park, Jung-Sun;Gi, Yeong-Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.648-653
    • /
    • 2007
  • In this study, we have generated fatigue load spectrum that is using to prediction of life time for the helicopter rotor blades. We derive utility helicopter missions for the sake of generating load spectrum. Helix and Felix are standard loading sequences which relate to the main rotors of helicopters with articulated and semi-rigid rotors respectively. We got scale factors which is applied to specific case and it did be obtained through the finite element analysis tools. The fatigue life of the rotor blade is estimated by using MSC/Fatigue. We suggest that generated our fatigue load spectrum in conjunction with small utility helicopter should use to rotor blade fatigue test of the korea helicopter program.

  • PDF

An Overview of Flight Test Planning and Test Results for the Development of Korean Utility Helicopter (한국형 기동헬기 개발을 위한 비행시험 계획 및 시험결과 개요)

  • Kwon, Hyuk-Jun;Park, Jaeyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.268-276
    • /
    • 2013
  • The objective of this paper is to give a general understanding for the development flight test of Korean Utility Helicopter(KUH). This paper contains the contents of detailed flight test plan, the type of flight test, an introduction to main flight test area, and the overview of flight test results. At the beginning, more than 8,500 test points were identified for airworthiness certification to show the compliance for the KUH development requirements. However, the number of flight test points were optimized to 7,800 at the end. To accomplish the test objectives, about 860 flight test sorties had been performed, and more than 1,000 test sorties were consumed for trouble shooting. This paper also describes some major issues faced during development flight test phase.

Bearingless Rotor Hub Composite Component Fatigue Analysis of Utility Helicopter to perform the Basic Mission (기본임무를 수행하는 기동헬기에 적용될 무베어링 허브 복합재 구성품 피로수명 해석)

  • Kim, Taejoo;Kee, Youngjoong;Kim, Deog-kwan;Kim, Seung-ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.383-389
    • /
    • 2013
  • Rotor system is a very important part which produces lift, thrust and control force in helicopter. Component of rotor system must endure various flight load for the required life. In helicopter rotor system, bearingless rotor system is the highest technology rotor system compare with articulated and hingeless rotor system. Baaringless rotor system is not include mechanical flap hinge, lag hinge and pitch bearing. Bearingless rotor component flexbeam which made by composite material has conduct hinge and bearing role instead of mechanical flap hinge, lag hinge and pitch bearing. These characteristics has less part number and lass weight than others. In this paper, conduct safe life analysis of bearingless composite component flexbeam and torque tube applying to utility helicopter load condition.

  • PDF

Vibration Reduction Devices for Korean Utility Helicopter (한국형기동헬기 진동저감장치)

  • Jung, Se-Un;Kwak, Dong-Il;Kim, Se-Hee;Choi, Jong-Ho;Shim, Dai-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.987-993
    • /
    • 2013
  • Korean Utility Helicopter(KUH) is the first korean-developed helicopter. Its first flight was performed in March 2010 and then its development was completed successfully by June 2012. During flight test phase, KUH faced various vibration problems and appropriate vibration-reduction devices were designed and applied to solve the problems. The vibration-reduction devices were applied to main rotor blades, main gear box(MGB) supporting structure, cockpit, cabin and pilot seats to reduce rotor-induced 4/rev vibration. Also, dome-fairing was introduced in order to reduce the tail-shake vibration. This paper shows design technique and flight test results for vibration-reduction devices that have been incorporated into KUH.

Instrument Flight Certification Process and Flight Test Results of Korean Utility Helicopter (한국형 기동헬기 계기비행 인증절차 및 비행시험 결과)

  • Kwon, Hyuk-Jun;Park, Jong-Hoo;Park, Jae-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.173-180
    • /
    • 2014
  • In this paper, the instrument flight certification process and flight test results of Korean Utility Helicopter (KUH) are presented. For the instrument flight certification, the suitability of installed equipments and instruments have been reviewed and verified by ground and flight tests. Next, static and dynamic stability test are conducted in accordance with FAR-29 Appendix B. The static stability is determined by the change of speed and attitude according to control inputs. The dynamic stability is evaluated by how quickly the response of the helicopter due to long and short period control inputs are decreased. The pilot workload evaluation are also carried out by simulated IMC flight tests. This paper presents the workload assessment results when some failures are occurred at cockpit instruments, engine or flight control systems as well as the normal situation. After the simulated IMC flight test is completed, actual instrument flight test are conducted in a real IMC environment according to the air traffic controls.

Design Improvement of Vent System for Korean Utility Helicopter's Anti-Explosion Fuel Tank (한국형 기동헬기 내폭발성 만족을 위한 연료 벤트 시스템 설계개선)

  • Kim, Joung-Hun;Kim, Chang-Young;Chang, Joong-Jin;Lee, Mal-Young;Shim, Dai-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Military helicopter is exposed to the enemy gun firing due to the low altitude flight of contour flight, hovering & nap of the Earth flight, therefore it has the high possibility to be exploded by the gun firing. Recently the Anti-ballistic requirement is required to get the high level of safety from gun firing in required operational capability. The first military utility helicopter of SURION has the Anti-ballistic requirement and explosion proof. In order to meet the requirement, OBIGGS is adopted for the first time in KUH. It is proven that Anti-Explosion capability is satisfied to requirement for improving vent system which was insufficiently designed in development period and related to Anti-explosion.

Development of Auxiliary Heater to Improve Korean Medical Evacuation Helicopter Winter Operational Capability

  • Kim, Se Un;Koo, Jeong Mo;Seo, Jeong Mi;Jeong, Won Chae
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.10-17
    • /
    • 2020
  • The Korean medical evacuation helicopter was developed based on the Korean Utility Helicopter (hereafter referred to as 'Surion'). It uses an auxiliary power unit and engine for heating during winter operation. The helicopter maintains the internal temperature of the aircraft using its bleed air to satisfy its operational capability. However, due to the air inflow through the gap between the aircraft skin and door, additional heating for operating the portable medical equipment and preventing hypothermia in evacuated patients is required. Accordingly, an electric auxiliary heater was developed for additional heating during winter operation, and environmental, durability, and performance tests were conducted per MIL-STD-810G and MIL-STD-461F. The auxiliary heater was verified per the tailored airworthiness certification criteria.

A Study on Load Spectrum for Fatigue Analysis of Helicopter Rotor Blades (헬리콥터 로터 블레이드의 피로해석을 위한 하중 스펙트럼연구)

  • Oh, Man-Seok;Kim, Hyun-Duk;Kee, Young-Jung;Park, Jung-Sun
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In this paper, we deducted the missions with respect to Korea utility helicopter (KUH) and consist of the scenarios which describe proper purpose of KUH. And so developed fatigue load spectrum of KUH by applying Helix that is fatigue load spectrum for blade of articulated helicopter rotor system. The developed load spectrum is applied to fatigue analysis of blade by modeled finite element with stress-life method (S-N). And we compared the result of fatigue analysis to prior to Helix for the sake of verifying the load spectrum that we generated.

  • PDF

Design Improvement of OBIGGS Abnormal Warning Lights up for Korean Utility Helicopter (한국형 기동헬기 OBIGGS 경고등 이상 점등현상 설계개선)

  • Kim, Joung-Hun;Lim, Hyun-Gyu;Lee, Ki-Hyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.6
    • /
    • pp.473-480
    • /
    • 2017
  • Military helicopters are equipped with OBIGGS System to prevent an explosion caused by the projectile. OBIGGS warning lights up should only operate when sensing fault, but it frequently worked without malfunction in the initial production process and the design improvements were required. In this paper, the cause of OBIGGS abnormal warning lights up was reviewed, the improvements were established and proven.

Handling Quality Improvements of Fly-By-Wire Helicopter using Combined Model Following Controller with Decoupler

  • Lee, Jangho;Kim, Eung-Tai;Ryu, Hyeok;Shim, Hyunchul
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.378-387
    • /
    • 2017
  • The combined model following control (MFC)-decoupler system is employed for a full authority fly-by-wire utility helicopter to enhance handling qualities. The MFC, which governs the vehicle to follow the prescribed model, is widely employed for modern helicopters. However, it may not be sufficient as helicopters often suffer significant cross coupling. The coupled responses between control axes of a helicopter increase the pilot's work load and may degrade handling qualities. As the decoupler is introduced to the MFC, the combined MFC-decoupler effectively solves the coupling problems and enhances handling qualities. The proposed system is verified via the handling qualities prediction using the mathematical dynamics model. The analysis results are confirmed through the piloted simulation.