• Title/Summary/Keyword: Korean surface temperature

Search Result 12,696, Processing Time 0.045 seconds

Effect of Carbonization Temperature on the Surface Temperature of Carbonized Board (탄화온도가 탄화보드의 표면온도에 미치는 영향)

  • Oh, Seung-Won;Hwang, Jung-Woo;Park, Sang Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.60-66
    • /
    • 2018
  • For new use development of carbonized board, we investigated the effect of carbonization temperature on the surface temperature of carbonized board manufactured from a plywood, particle board, MDF, and wood of Fraxinus rhynchophylla at different carbonization temperature ($400^{\circ}C{\sim}1100^{\circ}C$). The surface temperature of carbonized board precipitously increased until 12 minutes elapsed, after smoothly increased and thereafter which were stable after 20 minutes. The higher carbonization temperature increased density of carbonized board and surface temperature of carbonized board so that density is considered to influence surface temperature change. Moreover, carbonized boards kept heat for a long time because the descent velocity of carbonized boards' surface temperature was slower than that of heater's.

Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process (반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향)

  • Park, Jun-Su;Kwon, Hyun-Goo;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

Analysis and Measurement of Rough Surface Temperature Rise in Lubricated Condition (거친 표면의 마찰온도 해석 및 온도측정 실험에 관한 연구)

  • Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.23 no.2
    • /
    • pp.56-60
    • /
    • 2007
  • The main object of this study is to compare the results that have been concluded by the experiment and to estimate the temperature rise that can cause the contacting surface to be damaged. The former studies are based on the Blok and Jaeger formula. By these formulas we assume that two of the contacted objects are a kind of semi-infinite solid and with this assumption we can make a temperature analysis. But this method doesn't consider lubrication conditions and the calculation time requires a lot of time in that we have to face many difficulties in measuring the actual temperature rise. In this study we combines the semi-infinite solid method and the finite volume method to analyze the temperature of the contacting surface. And we measure temperature rise of the contact surface by dynamic thermocouple.

Climate change in Korea inferred from subsurface temperatures (한국의 지중온도를 이용한 기후변화연구)

  • Lee, Young-Min;Kim, Hyoung-Chan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF

A Study on the Accuracy Improvement of Land Surface Temperature Extraction by Remote Sensing Data (원격탐사 자료에 의한 지표온도추출 정확도 향상에 관한 연구)

  • Um, Dae-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.159-172
    • /
    • 2006
  • In this study, the series of Landsat TM/ETM+ images was acquired to extract land surface temperature for wide-area and executed geometric correction and radiometric correction. And the land surface temperature was extracted using NASA Model, and achieved the first correction by performing land coverage category for study area and applied characteristic emission rate. Land surface temperature which was acquired by the first correction was analyzed in correlation with Meteorological Administration's temperature data by regression analysis, and established correction formula. And I wished to improve accuracy of land surface temperature extraction using satellite image by second correcting deviations between two data using establishing correction formula. As a result, land surface temperature acquired by 1st and 2st correction could be corrected in mean deviation of about ${\pm}3.0^{\circ}C$ with Meteorological Administration data. Also, I could acquire land surface temperature about study area by higher accuracy by applying to other Landsat images for re-verification of study results.

  • PDF

A Study for Improvement of Temperature Distribution in Plunger Surface Cooling (브라운관용 플런저 냉각표면의 온도분포 개선을 위한 연구)

  • Kwak, Kyung-Min;Park, Ji-Yeol;Bai, Cheol-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.126-133
    • /
    • 2008
  • The main objective of the present study is to achieve linear temperature distribution of cooling surface of plunger. K type thermocouples are attached at the surface of plunger to measure temperature. Nozzle and insulating material are inserted in the pin hole of the plunger for this study. Cooling water flow enters at one nozzle and leaves at three nozzles. Flow through nozzle can be activated in the pin hole, temperature of hot point around hole is decreased. Meanwhile, insulating material blocks off heat transfer, temperature of cold point around hole is increased. By combination of nozzle and insulation, heat transfer of hole is controlled effectively, as result its, temperature of plunger surface shows linear temperature distribution.

Nondestructive Estimation of Average Wood Moisture Content Using Surface Temperature Rise by Radiation Heating and Moisture Gradient

  • Lee, Hyoung-Woo;Kim, Byung-Nam
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.38-42
    • /
    • 1999
  • Average moisture content of 30mm-thick Korean red pine(Pinus densiflora) was estimated nondestructively and continuously using surface temperature rise by radiation heating and moisture gradient profile in wood. The surface temperature rises increased as surface moisture contents decreased and good relationships were found between surface moisture contents and surface temperature rises at three different feed speeds of 10, 20 and 30 m/min. Average moisture content could be described as a function of surface moisture content and wood thickness.

  • PDF

Analyzing the Relationship between Climate Change and Anchovy Catch using a Cointegration Test (공적분 검정을 이용한 기후변화의 멸치 생산량에 대한 영향 분석)

  • EOM, Ki-Hyuk;KIM, Hong-Sik;HAN, In-Seong;KIM, Do-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1745-1754
    • /
    • 2015
  • This study aimed to analyze the relationship between sea temperatures and anchovy catch of Anchovy drag net fishery using annual time series data from 1970 to 2013. In the analysis, time series data on variables (CPUE, sea surface temperature, and 10m temperature) were estimated to be non-stationary from unit root tests, but one long-term equilibrium relation among variables was found from a cointegration test. From an exclusion test, a 10m temperature would not have relations with CPUE and sea surface temperature. The result of regression analysis on sea surface temperature and anchovy catch indicated that the sea surface temperature would have positive impacts on the anchovy catch. It means that when the sea surface temperature would increase, all other things including the current level of fishing effort being equal, the catch of anchovy was predicted to increase. More specifically, the result showed that when 1% of sea surface temperature increases, CPUE would be increased by 2.81%.

Comparison of variations in sea surface height with sea surface temperature and wind field in the Tropical Pacific Ocean

  • Chul, Kang-Sung;Schumann, Robert;Murai, Shunji;Kiyoshi, Honda;Kim, Young-Seup
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.225-230
    • /
    • 1998
  • The purpose of this study is to contribute the development of an El Nino prediction model. The objectives of the study are to (1) extract sea surface height data from the TOPEI/Poseidon altimeter, and (2) compare the relations among the sea surface height, sea surface temperature and wind field. NOAA AVHRR Multi-channel data is used for sea surface temperature and wind data is derived from ERS 1, 2 AMI wind scatterometer. The results showed that sea surface height has increased significantly during the El Nino season. The sea surface height is positively related to sea surface temperature and negatively related to zonal wind.

  • PDF

Estimation of Local Surface Temperature from EBM with the Use of GRID/GIS and Remote Sensed data (GRID/GIS 및 RS 자료를 이용한 에너지 평형 모형으로부터의 국지적 지표 온도 산출)

  • 신선희;하경자;김재환;오현미;조명희
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.2
    • /
    • pp.103-116
    • /
    • 2004
  • The mesoscale atmospheric models to produce surface temperature can not generally consider the effect of the sloped terrain for direct solar radiation. These have not showed the regional difference of solar radiation and as a result, have made the big error in the local surface temperature. Therefore, we wished to represent the exact locality of surface temperature by considering the geometric properties of surface as well as the vegetated properties of surface. The purpose of the study is to produce local surface ground temperature in sloped terrain diagnostically using surface Energy Balance Model (EBM) with the use of GRID model in Geographic Information Systems (GIS). In this study, surface inhomogeneity over southeastern part of Korean peninsula are considered in estimation of the absorbed surface solar radiation in terms of the illumination angle, depending on topographical aspect and slope in GRID. Also, the properties of vegetated surface which the major components for the variability of surface temperature are considered in terms of NDVI. The results of our study show the locally changes in the surface ground temperature due to local ground aspect and slope effect and local properties of vegetated surface. The more detailed distribution of local surface temperature may drive the local circulation at lower atmospheric and it may explain better the real local circulation.