• Title/Summary/Keyword: Korean surface temperature

Search Result 12,696, Processing Time 0.046 seconds

Analysis and Calculation of Hourly Surface Temperature Based on Typical Meterorological Data for Major Cities in Korea (국내 주요도시의 표준기상자료를 이용한 시간당 표면온도 산출 및 분석)

  • Lee, Kwan-Ho;Cho, Hyun-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.123-128
    • /
    • 2012
  • Computer simulation of buildings and solar energy systems is being used increasingly in energy assessments and design. The purpose of our work is to predict the surface temperature on inclined surfaces based on ISO-TRY typical weather data. To reach this goal, three studies were performed. They consisted of quantifying the accuracy of various well-known three models. The first type of models calculated diffuse horizontal irradiations from global ones and the second type models computed global irradiations on inclined planes from diffuse and global components on a horizontal surface. The third type of model calculated long-wave radiation and surface temperature from ISO-TRY typical weather data. The proposed model can provide an alternative to building designers in estimating the surface temperature and solar irradiation on inclined surfaces where only the typical meteorological data are available.

Density and Corrosion Property Improvement of Zn-Mg Coatings by Controlling the Substrate Temperature during the Deposition (증착 기판 온도 제어에 따른 Zn-Mg 박막의 치밀도 및 내식성 향상에 관한 연구)

  • Song, Myeon-Kyu;La, Joung-Hyun;Kim, Hoe-Kun;Lee, Sang-Yul
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.4
    • /
    • pp.266-271
    • /
    • 2017
  • In this study, the corrosion resistance of Zn-3wt.%Mg coating was enhanced by controlling the density of coating. During the deposition the substrate temperature was controlled via an intermittent deposition process, resulting in the improvement of coating density. The maximum substrate temperature during this intermittent deposition process could be controlled from $200^{\circ}C$ to $80^{\circ}C$, depending upon the number of coating layer. The density of Zn-3 wt.%Mg coating increased from 76.1 % to 95.8 % as the substrate temperature was controlled. The salt spray test results revealed that the corrosion resistance of Zn-Mg coated steel could increase 3 times by increasing the density in coatings, while adhesion strength of coating was not changed significantly during 0-T bending test.

An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting (전기발열시트 표면가열 양생공법의 현장적용 연구)

  • 김형래;조호규;김찬수;지남용
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

Surface characteristics of Si-doped $In_{0.1}Ga_{0.9}As$ epilayers due to Si-cell temperature (Si이 첨가된 $In_{0.1}Ga_{0.9}As$ 에피층의 Sit셀 온도에 따른 표면특성 연구)

  • 김동렬;이동율;배인호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.551-556
    • /
    • 2000
  • We have investigated the effect of surface In composition with Si cell temperature on the In$_{0.1}$/Ga$_{0.9}$/As epilayers grown on GaAs substrates. The epilayers were grown by molecular beam epitaxy(MBE) method and were characterized by the pthotoreflectance(PR) measurements. The E$_{o}$ bandgap energies of In$_{0.1}$/Ga$_{0.9}$/As epilayers were observed at around 1.28 eV at room temperature, and the additional shoulder peaks appeared at the higher energies than E$_{o}$ with increase of Si doping concentrations. The intensity of the additional shoulder peak was decreased with lowering the measurement temperature and the peak disappeared with the increase of surface etching time. This results hows that In composition at surface of InGaAs epilayer is decreased with the increase of the doping cell temperature. We consider that the reason of the decrease of In composition at the surface should be due to In re-evaporation from the surface by radiation heat of Si doping cell.ell.ell.ell.

  • PDF

A Study of Anti-Condensation on the Surface for Aluminum Butterfly Valves (알루미늄 버터플라이밸브의 표면 결로방지에 관한 연구)

  • Kwak, Kyung-Min;Lee, Joong-Hyoung;Cho, Kyung-Chul;Lee, Eun-Ha
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.73-79
    • /
    • 2021
  • The objective of this study is to prevent or decrease condensation on the surface of aluminum butterfly valves used in high humidity air conditions. We proposed a new valve with an anti-condensation device, a heat resistance medium, instead of a conventional valve. We, then, compared the surface temperature distribution between the proposed and conventional valves using experimental and analytical methods. The size of the evaluated valve is 100A and fluid conditions are 35℃/RH 75% in the air outside the valve and 5℃ in the cooling water inside the valve. The experimental results show that the surface temperature of the proposed valve is 23~42% higher than that of a conventional valve, thereby exhibiting an anti-condensation effect. As a result, we observed the complete prevention of condensation on a gear box mounted to the proposed valve, showing surface temperature distribution above the dew point temperature of air. The analytical results are in agreement with the trends in experimental results.

A Study on the GIS for The Sea Environmental Management II (- Developing a Line Density Algorithm for The Quantification to the Sea Surface Temperature Distribution - ) (GIS을 활용한 해양환경관리에 관한 연구 II (해수면 수온분포의 정량화를 위한 선 밀도 알고리즘 개발))

  • Lee, Hyoung-Min;Park, Gi-Hark
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.61-76
    • /
    • 2006
  • A Line Density algorithm was developed to quantify the sea surface temperature distribution using NOAA Sea Surface Temperature(SST) data and Geographic Information Systems(GIS), In addition, a GIS based automation model was designed to extract the Line Density Indices were determined by applying K-means Cluster. SST data in terms of March to May obtained on the coastal area of the Uljin from 2001 to 2004 in spring were used to make two data sets of average sea water temperature map in terms of year as well as month. From the result it was formed that water temperature gradient in April was the strongest among the other months, In particular very strog formation of oceanic front as well as temperature gradients were observed in front of the coastal area around Wonduk and Jukbyeon countries. Because those coastal area is a confront zone of two cold and a warm. It is expected that the development of a Line Density Algorithm would contribute to quantify of the SST for the research of Sea Surface Front(SSF) related to marine life management and the sea environmental conservation.

Effects of the Incidence Angle and Temperature on the Performance of a Thin-Film CIGS Solar Cell for Solar Powered UAVs (태양광무인기를 위한 박막형 태양전지의 입사각 및 온도에 따른 성능분석)

  • Shin, Donghun;Kim, Tae Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.55.2-55.2
    • /
    • 2011
  • This research aims to study the effects of the incidence angle and surface temperature on the power generation performance of a thin-film CIGS solar cell for solar powered unmanned aerial vehicles (UAVs). The test rig consists of a unit CIGS solar cell is installed on a table whose angle is controlled manually. A K-type thermocouple is attached to the solar cell surface for temperature measurements. A solar module analyzer measures the voltage and current generated from the test solar cell. The solar module analyzer also calculates the maximum solar power and efficiency of the solar cell. All test data are acquired in a PC. Test results show that the solar cell efficiency decreases significantly with increasing incidence angle and increasing surface temperature in general. As the incidence angle increases from 0 degree to 90 degree, the solar cell efficiency decreases by 60%. The solar cell efficiency decreases by 10% with increasing solar cell surface temperature from $20^{\circ}C$ to $30^{\circ}C$, for exmaple. The direct cooling method of the solar cell using dry ice decreases dramatically the solar cell surface temperature, thus increasing the solar cell efficiency by 15%.

  • PDF

Influence of Operating Condition on Grinding Temperature in High Effect Grinding (고능률 가공에서 연삭 온도에 미치는 연삭 조건의 영향)

  • 김남경;강대민;송지복
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.1
    • /
    • pp.31-39
    • /
    • 1990
  • In this paper, the influence of the table speed, metal removal rate and grinding fluid on long wheel workpiece contact zone at high effect grinding was investigated by theoretical analyses and measuring the temperature, and discussed by the temperature distribution in grinding surface layer. Main results obtained are as follows, 1) Rega.dless of the table speed, the temperature gap of the workpiece(heat influx) is about 6-8 times as high in dry condition as in wet condition. 2) Good grinding condition can be obtained owing to the effect of grinding fluid without any burning defect under the condition of the metal removal rate(1.0mm$^3$/mm.s) in case of wet grinding. 3) When the depth from the surface layer is about 1.25-1.5mm under the condition of the slow table speed, surface temperature goes up higher as the table speed slows down, because long contact time is laked at the surface layer. 4) In case of the same metal removal rate, the lower the table speed becomes, the higher the surface temperature is, because grinding depth has a far more influence on wheel workpiece contact zone than the table speed.

  • PDF

Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer (하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

Study on the Surface Roughness of the Epoxy resins) (엑폭시 수지의 절삭가공시 표면거칠기에 관한 연구)

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.64-74
    • /
    • 1996
  • The meachanism for cutting epoxy resins specimens which were specially provided was experimentally investigated to obtain a fine surface finish. the specimens were cut the three-dimensional undrer dry conditions using a lathe. the relationship between the topography of the cut surface due to the change rate of temperature of the cutting condition using sintered carbides (P20, K10, KT150) was investigated. the main results obtained are as follows: 1) The change rate of temperature of the cutting edge is increased in nearly proportion ot cutting speed feed rate depth of cut. 2)The profile of surface roughness were regulated k10 but irregulated P20 KT150. 3) The surface roughness value decreased K10 rather than P20 KT150. 3) The surface roughness value decreased K10 rather than P20 KT 150.4)The cutting resistance increased thrust force rather than cutting force due to the visco-elastic material of epoxy resins.

  • PDF