The analysis of defects types and patterns in high-rise residential buildings (초고층 주상복합 건물의 하자 발생 유형 및 분석 연구)

  • Seo, Jang-Woo;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.93-101
    • /
    • 2009
  • Recently, public interest in housing defects, such as construction errors, occupiers' complaints, faults in production, and so on, is increasing. In addition, the construction requirements of high-rise residential buildings have increased, due to the higher prices of urban areas, especially in metropolitan areas. While previous research has focused on the defects occurring in apartment housing complexes, research has not been carried out on the defects occurring in high-rise residential buildings. In this paper, the defects patterns and characteristics of high-rise residential buildings are examined and analyzed and a defect management plan is then suggested. In order to do this, we collected the defects data of high-rise residential buildings recorded by 2,299 of 2,327 occupants. The defect occurrence rate (DOR) in the residential area is 98.8%. The frequency rate of defect occurrence over the total defect occurrence since building completion is 63.28% during the first year, 24.63% (second year), 6.88% (third year), 2.27% (fourth year), and 2.53% (fifth year). The result of correlation analysis between work types showed that there is a relationship between the built-in furniture and electronics (F&E) and painting works, and the F&E and masonry works, such as marble finishing. We expect that this research will assist in the efforts to decrease the number of defects in high-rise buildings.

A Numerical Analysis for Fire Spread Mechanism of Residential Building Fire (주거용 건축물의 화염전파 현상에 대한 수치해석적 검토)

  • Ahn, Chan-Sol;Kim, Heung-Youl;You, Yong-Ho;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • This study is intended to present a computational thermal model for a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the fire properties of a residential fire, we made some numerical models of combustibles and residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator (FDS) was used with Large Eddy Simulation (LES) model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.

A Basic Research in Three-Dimensional Residential Open Building;Focused on the of High Story Height in PLUS 50 experimental housing (입체형 오픈 하우징에 관한 기초적 연구;한국건설기술연구원 PLUS 50 실험주택의 고층고 주호를 중심으로)

  • Kim, Soo-Am;Lee, Sung-Ok;Lee, Bo-Ra;Hwang, Eun-Kyung;Lim, Seok-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.131-135
    • /
    • 2006
  • Many alternatives on the residential open building have been researched for corresponding high flexibility and possibility of remodeling in Korea as well. However, existing researches only dealt with two-dimensional floor plan. All buildings as well as apartment housing must have been examined various spatial aspect, three-dimensional not two-dimensional. It will examine basic method of three-dimensional flexible unit system to add to three-dimensional usage method overcoming these limitations. The purpose of this study is to propose the system of three-dimensional residential open building in Korea after examining possibility of flexibility of residential open building in 1.5 times of existing floor height.

  • PDF

A STUDY FOR FIRE EXTENSION MECHANISM BETWEEN FLOORS IN A RESIDENTIAL BUILDING WITH NUMERICAL MODELING (주거형 빌딩의 층간 화염전이 화재해석 모델링)

  • Ahn, Chan-Sol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.512-517
    • /
    • 2011
  • This study is intended for validation of numerical modeling of a residential building which is made to simulate a phenomenon of fire extension from floor to floor. A common residential building which has the area of 80m2 each floor and some combustibles were chosen for numerical modeling. The combustible models were verified through comparing results of numerical simulations and real fire tests. For computational analysis, the Fire Dynamics Simulator was used with Large Eddy Simulation model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

  • PDF

A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings (주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.

A Study on the Korean-Chinese Residential Spaces of Wu-lin Village in Jiao-he, China (중국 오림향 조선족 주거공간에 대한 연구)

  • Jung, Yun-Sang;Lin, Jin-Hua
    • Journal of architectural history
    • /
    • v.24 no.2
    • /
    • pp.35-44
    • /
    • 2015
  • The purpose of this study is its residential spaces through the analysis of exterior space and interior space at Wu-lin Village(烏林屯) in Jiao-he, China. The method of this study is to search for documentation, interview, residents, make a survey of these villages about immigration history, surroundings, topographical keynotes, administration system, residential number, residential style, site composition, etc. The residents moved from Yen-bien and Jiao-he in China etc. The ancestor moved from North of Gyeong-Sang Province in South of Korea, North of Ham-Gyeong Province in North of Korea etc. The main road divides the village into two parts: the north quarter, Wu-lin Village, typified by the Chinese house, and the south quarter, You-Yi Village(友誼村), typified by the Korean-Chinese house. The houses is compose of main building and an accessory building. The main building looking south. The vegetable garden is around main buildings. The main building is compose of an On-dol room(a hot-floored room) and a kitchen, a corridor etc.

A Study on the Characteristics of Space Utilization after converting of Residential District in a New Development Area - Focused on Dunsan of Daejeon City - (신개발지 일반주거지역의 용도전환시 공간변용 특성에 관한 연구 - 대전 둔산 신시가지를 중심으로 -)

  • Park, Jung-A;Kang, In-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • The purpose of this study is to find the characteristics of space utilization and the problems that follows after converting in a new developmental residential area. This study used the content-analysis method and analysis was made on the floor plans for 95 different conversion cases. Above all, 190 unit plans (the unit plans for conversion before and after) were analyzed. The results of this study were as follows; 1) There were 8 types of conversion according to such usages as residential, commercial and residential-commercial buildings. 2) In the case of conversions, from residential to commercial, there was a tendency each floor was integrated to exclusive use for commercial or commercial with small portions of residential usage. And in the case of conversions from commercial to residential, there was a tendency that all space of each floor were changed to exclusive usages for residential purposes. 3) In case of usage conversion from commercial to residential, there were constraints for balcony installation, because of its original lot-structure and building equipments. Also, when the basement was converted for residential purpose, there was no possibility for an extra lighting or ways to ventilate the area.

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

A study of Improvement for Residential Environment according to Segementation of Residential Zoning (주거지역 종세분화에 따른 주거환경 개선에 관한 연구 - 바람길을 중심으로 -)

  • Kim, Dae-Wuk;Jung, Eung-Ho;Ryu, Ji-Won;Cha, Jae-Gyu;Lee, Jun-Young
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.101-109
    • /
    • 2010
  • Various environmental problems due to rapid industrialization and urbanization have worsened to such an extent that they threaten the environmental restitution of the globe and become a critical international issue. Korean government has presented the concept of green growth as a new state vision for the next 60 years and is making efforts to solve these environmental problems. Daegu Metropolitan City has faced various environmental problems including overpopulation of the city, traffic pollution, household waste accumulation and the green zone problem because of the increase of urbanization over the last few decades. As such urbanization continues, the quality of residential environments is rapidly deteriorating and the intensive use of the land leads to an increase of building area, raising the temperatures of cities. There have therefore been demands for healthy, pleasant and satisfying residential environments and for the improvement of existing residential environments, and this demand has been fully recognized by society. Nevertheless, current residential complex developments concentrate only on raising the efficiency of land use. In related laws of the past (Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) an attempt was made to impose a standard to segmentalize the building-to-land ratio, floor area ratio and regulations of number of floors vertically. However, these laws have now been abolished and the regulations are being eased. The purpose of this study was to analyze the characteristics of the floating wind before and after the vertical segmentation of residential areas (Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) by using KLAM_21, a model that enables analysis and prediction of the flow and generation of cold wind. The purpose is also to present a plan to improve the quality of residential areas when developing a building lot and redeveloping housing areas.