• 제목/요약/키워드: Korean concrete Institute

검색결과 4,807건 처리시간 0.029초

기상자료를 이용한 한중콘크리트 적용 기간 산정 (Determination of Cold Weather Concrete Periods Using Meteorological Data of Republic of Korea)

  • 정지만;한준희;백성진;박재웅;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.57-58
    • /
    • 2023
  • This study is to estimate cold weather concrete periods by analyzing data of Korea Meteorological Administration in terms of recently revised cold weather concrete regulation of Korea Concrete Institute.

  • PDF

The Quality Status of Aggregate for Domestic Ready-mixed Concrete and the Effect of Aggregate Quality in Concrete

  • Kim, Yong-Ro;Lee, Jae-Hyun;Min, Choong-Siek;Park, Jong-Ho
    • 한국건축시공학회지
    • /
    • 제14권1호
    • /
    • pp.11-20
    • /
    • 2014
  • This research examined the effect of the quality of aggregate on concrete workability and compressive strength through an investigation into regional aggregate used in domestic ready mixed concrete plants. Through the research, it was found that aggregate for ready mixed concrete shows poor quality overall. The main factor of deterioration in the quality of the concrete is the particle size of fine aggregate and fine particle content in coarse aggregate. The quality of aggregate significantly influences concrete's workability, which is defined based on 0.08mm passage related with powder and absorption. In addition, poor aggregate quality leads to increased water content in concrete to secure workability, which is related with a decline in the compressive strength and durability of concrete.

Assessment of Mass Fraction and Melting Temperature for the Application of Limestone Concrete and Siliceous Concrete to Nuclear Reactor Basemat Considering Molten Coree-Concrete Interaction

  • Lee, Hojae;Cho, Jae-Leon;Yoon, Eui-Sik;Cho, Myungsug;Kim, Do-Gyeum
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.448-456
    • /
    • 2016
  • Severe accident scenarios in nuclear reactors, such as nuclear meltdown, reveal that an extremely hot molten core may fall into the nuclear reactor cavity and seriously affect the safety of the nuclear containment vessel due to the chain reaction caused by the reaction between the molten core and concrete. This paper reports on research focused on the type and amount of vapor produced during the reaction between a high-temperature molten core and concrete, as well as on the erosion rate of concrete and the heat transfer characteristics at its vicinity. This study identifies themass fraction and melting temperature as the most influential properties of concrete necessary for a safety analysis conducted in relation to the thermal interaction between the molten core and the basemat concrete. The types of concrete that are actually used in nuclear reactor cavities were investigated. The $H_2O$ content in concrete required for the computation of the relative amount of gases generated by the chemical reaction of the vapor, the quantity of $CO_2$ necessary for computing the cooling speed of the molten core, and the melting temperature of concrete are evaluated experimentally for the molten core-concrete interaction analysis.

고강도 콘크리트 강도별 염분확산계수 및 편차에 관한 연구 (A Study on Salt Diffusion Coefficient and Deviation by Strength of High-Strength Concrete)

  • 박동천;석원균;전현수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2022
  • High-strength concrete is used for building durability on the coast. It is common to order and produce the concrete from several ready mixed concrete companies. The concrete in Busan was also commissioned by 12 ready mixed concrete companies. The compressive strength and salt diffusion coefficient were measured. The average value and deviation were analyzed.

  • PDF

VOLUME REDUCTION OF DISMANTLED CONCRETE WASTES GENERATED FROM KRR-2 AND UCP

  • Min, Byung-Youn;Choi, Wang-Kyu;Lee, Kune-Woo
    • Nuclear Engineering and Technology
    • /
    • 제42권2호
    • /
    • pp.175-182
    • /
    • 2010
  • As part of a fundamental study on the volume reduction of contaminated concrete wastes, the separation characteristics of the aggregates and the distribution of the radioactivity in the aggregates were investigated. Radioisotope $^{60}Co$ was artificially used as a model contaminant for non-radioactive crushed concrete waste. Volume reduction for radioactively contaminated dismantled concrete wastes was carried out using activated heavy weight concrete taken from the Korea Research Reactor 2 (KRR-2) and light weight concrete from the Uranium Conversion Plant (UCP). The results showed that most of the $^{60}Co$ nuclide was easily separated from the contaminated dismantled concrete waste and was concentrated mainly in the porous fine cement paste. The heating temperature was found to be one of the effective parameters in the removal of the radionuclide from concrete waste. The volume reduction rate achieved was above 80% for the KRR-2 concrete wastes and above 75% for the UCP concrete wastes by thermal and mechanical treatment.

재생콘크리트 강도 예측 프로그램 개발을 위한 재생콘크리트의 역학적 특성과 내구성에 관한 자료 분석 (Analysis of data on mechanical properties and durability of recycled aggregate concrete to develope estimation program of recycled aggregate concrete strength)

  • 최희복;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.15-19
    • /
    • 2004
  • The production of waste concrete is increased continuously by urban renewal, reconstruction, remodeling, and so on. So the positive use of recycled aggregate concrete is needed. Research for recycled aggregate concrete that use recycled aggregate from the mid-80s to solve environmental problem of aggregate insufficiency and waste concrete is consisting vigorously. However, specifications and mix design about waste concrete's use are evading use of recycled aggregate concrete yet in spot being not taken a triangular position. Therefore. it analyze existing research data for recycled aggregate concrete collection to develop strength estimate program in this research. Recycled aggregate concrete's strength estimate program if specifications and mix design about recycled aggregate concrete are taken a triangular position to foundation recycled aggregate concrete's practical use to increase judge.

  • PDF

부산지역 레미콘사의 콘크리트의 압축강도와 염소이온 확산계수 (Chloride Ion Diffusion Coefficient and Compressive Strength of the Concrete Produced by Ready Mixed Concrete Company in Busan)

  • 박동천;방중석;김용로;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.11-12
    • /
    • 2017
  • The properties of concrete produced by ready mixed concrete company in Busan were tested. Because the concrete was mixed with blast furnace slag and fly ash, the compressive strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design.

  • PDF

시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 압축강도특성을 중심으로 - (An Experimental Study of Precast Concrete Alters Cement Types of High-Strength Concrete)

  • 박흥이;기전도;김성진;이회근;박병근;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.65-68
    • /
    • 2009
  • Recently, as architectural concrete structures become high-rise and megastructured, concrete become high-strengthened and, by ensuring products of more stability, and rationalization of construction are required.large cross-sectional precast concrete members such as columns show large temperature increase in manufacturing process not only by external heating but also by concrete itself's hydration heating. Therefore, it is expected that specimen for management to predict strength and compression strength of precast concrete member shows different strength characteristics. Concerning this, in order to suggest strength characteristics of high strength mass concrete suitable for precast concrete application, this study comprises the inclusive investigations on the relations between core strength and the strength characteristics per member cross-section dimensional value and per water-bonding material ratio value.

  • PDF

양생온도 변화가 고성능 콘크리트의 압축강도에 미치는 영향에 관한 연구 (A Study on the Effects of Curing Temperature for Compressive Strength of High Performance Concrete)

  • 노인철
    • 한국건축시공학회지
    • /
    • 제2권4호
    • /
    • pp.163-168
    • /
    • 2002
  • The object of this study is to define the characteristics of high performance concrete with varing compressive strength of concrete and curing temperature. The major test variables are 1) high strength concrete(500kg/$cm^2$) and ordinary strength concrete(240kg/$cm^2$) compressive strength, 2) curing temperature and condition, 3) concrete curing age, 4) three types of cement. From the test results were shown that curing temperature and curing conditions were also very effective for high strength concrete and ordinary strength concrete, and concrete were largely effected by cement type and temperature during the hydration reaction process. This paper describes the effect of curing temperature for strength and characteristics of high performance concrete.

Radiological safety evaluation of dismantled radioactive concrete from Kori Unit 1 in the disposal and recycling process

  • Lee, ChoongWie;Kim, Hee Reyoung;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.2019-2024
    • /
    • 2021
  • For evaluating the radiological safety of dismantled concrete, the process of disposal and recycling of the radioactive concrete generated during the dismantling of Kori Unit 1 is analyzed. Four scenarios are derived based on the analysis of the concrete recycling and disposal process, and the potential exposure to the workers and public during this process are calculated. VISIPLAN and RESRAD code are used for evaluating the dosages received by the workers and public in the following four scenarios: concrete inspection, transport of concrete by the truck driver, driving on a recycled concrete road, and public living near the landfilled concrete waste. Two worker exposure scenarios in the processing of concrete and two public exposure scenarios in recycling and disposal are considered; in all the scenarios, the exposure dose does not exceed the annual dose limit for each representative.