• Title/Summary/Keyword: Korean Tank

Search Result 4,098, Processing Time 0.038 seconds

Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection (코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, the stress and deformation characteristics of corner protection in which is fabricated in an insulation area have been analyzed using a finite element method. The proposed corner protection may increase the strength and leakage safeties of conventional LNG storage system. The stress and deformation of LNG storage tank system are computed for an insulation panel box, membrane inner tank, and prestressed concrete outer tank. The FEM computed results indicate that the stress and displacement of new membrane LNG tank system with a corner protection between an inner tank and an outer tank are reduced in comparison to those of a conventional membrane LNG tank. This is explained that the strength safety of LNG membrane tank system may be increased due to a strength stiffness of a corner protection.

  • PDF

The Development of Compressive Strength Estimation Equation for LNG Storage Tank using Rebound Hardness Method (반발경도법을 이용한 LNG 저장탱크 콘크리트의 압축강도 추정식 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.26-32
    • /
    • 2017
  • Outer tank concretes of LNG storage tank are composed of prestressed concrete structures that act as a protective wall. The danger such as the collapse of structures will exist if concrete structures is not secured due to the deterioration. Concrete compressive strength directly related to the safety of structures can be predicted by using estimation equation of compressive strength through rebound hardness test and ultrasonic wave velocity method. But, there is no the estimation equation of LNG storage tank for a relation between NDT data and real strength. In this study, to obtain more accurate real strengths for LNG storage tank, core specimens were sampled from walls of pilot LNG storage tank. The rebound hardness test of general NDT for concrete structures was carried out at each 3 positions for the four areas. The compressive strength estimation equation of LNG storage tank was developed by using the data for rebound hardness test of pilot LNG storage tank and compressive strength test of sampled concrete cores.

IMPACT ANALYSIS OF A WATER STORAGE TANK

  • Jhung, Myung-Jo;Jo, Jong-Chull;Jeong, Sang-Jin
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.681-688
    • /
    • 2006
  • This study investigates the dynamic response characteristics of a structure impacted by a high speed projectile. The impact of a 300 kg projectile on a water storage tank is simulated by the general purpose computer codes ANSYS and LS-DYNA. Several methods to simulate the impact are considered and their results are compared. Based upon this, an alternative impact analysis method that is equivalent to an explicit dynamic analysis is proposed. The effect of fluid on the responses of the tank is also addressed.

A Low Phase Noise 5.5-GHz SiGe VCO Having 10% Bandwidth

  • Lee Ja-Yol;Park Chan Woo;Bae Hyun-Cheol;Kang Jin-Young;Kim Bo-Woo;Oh Seung-Hyeub
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.4
    • /
    • pp.168-174
    • /
    • 2004
  • A bandwidth-enhanced and phase noise-improved differential LC-tank VCO is proposed in this paper. By connecting the varactors to the bases of the cross-coupled transistors of the proposed LC-tank VCO, its input negative resistance has been widened. Also, the feedback capacitor Cc in the cross-coupling path of the proposed LC-tank VCO attenuates the output common-mode level modulated by the low-frequency noise because the modulated common-mode level jitters the varactor bias point and degrades phase noise. Compared with the fabricated conventional LC-tank VCO, the proposed LC-tank VCO demonstrates $200\;\%$ enhancement in tuning range, and 6 - dB improvement in phase noise at 6 MHz offset frequency from 5.4-GHz carrier. We achieved the phase noise of - 106 dBc/Hz at 6 MHz offset, and $10\;\%$ tuning range from the proposed LC-tank VCO. The proposed LC-tank VCO consumes 12 mA at 2.5 V supply voltage.

Experimental Study on the Thermal Storage Efficiency Through Variable Porous Mainfolds in a Test Storage Tank (실험 저장조내의 유입구 형상변화에 따른 열 저장효율에 관한 실험적 연구)

  • Pak, Ee-Tong;Hwang, Sung-Il;Choi, Young-Il
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.37-43
    • /
    • 1989
  • This paper dealt with thermal storage efficiency due to difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank [$0.5m{\times}0.5m{\times}1.0m$] and the temperature of water flowing into the tank, flow rate of water flowing into the tank and shape of porous manifold which water flow into the tank through. As results of experiments; (1) When the flow rate was constant and the diameter of porous section decreased by 8mm, 6mm, and 4mm, the thermal storage efficiency increased. (2) When the diameter of porous section was constant and the difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank and the temperature of water flowing into the tank increased by -30, -20, -10, 5, 10, 15 ($^{\circ}C$), the thermal storage efficiency increased. (3) When the($T_{\infty}-Ti$) was constant and the flow rate decreased by 0.8, 0.4, 0.25(LPM), the thermal storage efficiency increased. (4) When the shape of porous section was rigid, the thermal storage efficiency was the most effective, and with establishing flexible porous section or mesh, the effective thermal storage efficiency was obtained.

  • PDF

Study of Vibration Fatigue Test for Urea Tank of Diesel Vehicle Considering Vibration Characteristics (디젤차량 요소수탱크의 진동 특성을 고려한 진동내구시험법 연구)

  • Yoon, Ji Soo
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.213-219
    • /
    • 2018
  • Purpose: Satisfying the environmental regulations, the automobile manufacturer should install urea tank, which is a key component of the urea system. However, due to the limitations of existing layouts, it may be mounted which is disadvantageous to vibration and shock resulting in durability robust. analyze the factors affecting the durability life of urea tank and the vibration characteristics through RLDA. In this study, clarify the limit of the current practice test method of urea tank and analyze the possibility of the new vibration test method in the system unit reflecting the characteristics of actual use condition. Methods: Analyzing the factors affecting the durability life of urea tank and the vibration characteristics through PSD & FDS of RLDA that actual vehicle driving data on durability test road. Results: The limit of the uniform width/single frequency test method of urea tank is clarifed and the positive prospects of the new test method are discovered. Conclusion: The vibration durability test with PSD method in system unit effectively reflects the magnitude and frequency characteristics of field vibration.

Thermal Stratification Effects Near an Interface by Horizontal Inflow of Cold Water in Thermal Storage Tank (냉수가 수평유입되는 열저장탱크의 중간 경계면 부근에서의 열성층 효과)

  • Hwang, Sung-Il;Pak, Ee-Tong
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.46-56
    • /
    • 1988
  • This investigation concerns thermal stratification of the water due to the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the water in the test tank (1m wide, 1m high, 2.1m long) and the temperature of the inflow water into the tank; flow rate of circulating water and height of the sink diffuser in the test tank. The additional objectives was to observe a stratification phenomena near an interface by measuring the velosities and the temperature difference and investigate an availabilities of the better effective hot water through establishing thermocline near an interface around the bottom of the tank. Following results were obtained through the experiments. 1. When the flow rate was constant and the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the flow in the test tank and the temperature of the inflow water increased by 5.6, 9.5, 13.5($^{\circ}C$), obtained the better effective advantage of hot water and the stress near an interface increased gradually. 2. When the ${\Delta}T=T_{\infty}-T_i$ was constant and flow rate increased by 4.0, 4.8, 6.4, 8.0 (LPM), obtained the better effective advent age of hot water and the mean stress near an interface increased gradually. 3. When the height of the sink diffuser was 25cm from tank bottom in comparison with 50cm, obtained the better effective advantage of hot water and the mean stress near an interface increased.

  • PDF

Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 1:Verification Experiment) (나선유로에 의한 태양열 축열조 성층화 촉진(제1보 실증실험))

  • Kwon, Jae-Wook;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.336-342
    • /
    • 2012
  • Large-scale active solar heat systems are generally using heat exchanger between collector and storage tank loops to prevent damage by freezing. It is difficult to maintain stratification in a storage tank in the system owing to greater flow rate enhancing heat transfer. In the previous study, we introduced a spiral-jacketed storage tank and obtained good results to keep system performance of general level without better stratification. We added a scroll-shaped heat exchanger coil on the upper part in the spiral-jacketed storage tank. As a result of the experiment, it was verified that degree of stratification of the new type storage tank is higher than that of the previous one with a possibility of better collector efficiency and solar fraction.

Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank (순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구)

  • Jeon, Yong-Seok;Park, Hong-Hee;Lee, Joo-Seoung;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.

Preliminary Study on Deformation During Hydrostatic Testing in a Deep Tank

  • Kim, Geun-Gon;An, Tae-Hyun;Lee, Tak-Kee
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.115-124
    • /
    • 2022
  • There are many different types of tanks on ships that meet various requirements. Each tank is required to undergo hydrostatic testing according to the Ship Safety Act after being installed onboard. In some hydrostatic tests, excessive deformation may occur. The overpressure of the air in the tank generated during testing is one of the possible causes of deformation. Based on the dimensions of the tank, nozzle, and pipes installed, it was confirmed that the overpressure of the air can cause problems with the structure, according to the Bernoulli equation. Additionally, finite element analysis (FEA) was performed on the tank structure to confirm the deformation and the stress occurring in the structure. From the perspective of deformation, the maximum deflection limit was set based on the criteria provided by the Eurocode and DNV. From the perspective of stress, the structural safety assessment was performed by comparing the allowable stress and equivalent stress generated in the structure. To determine whether the behavior of the actual structure was well implemented via FEA, beam theory was applied to the tank structure and compared with the FEA results. As a result of the analysis, severe deformation was found in some cases. This means that the overpressure of the air may be the cause of actual deformation. It was also confirmed that permanent deformation may occur.