• Title/Summary/Keyword: Korean Magazine

Search Result 113,520, Processing Time 0.103 seconds

Studies on the Effects of Various Methods of Rotation Irrigation System Affecting on The Growth, Yield of Rice Plants and Its Optimum Facilities (수환관개방법의 차이가 수도생육 및 수량에 미치는 영향과 그 적정시설에 관한 연구)

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.2
    • /
    • pp.1937-1947
    • /
    • 1970
  • This experiment was conducted, making use of the 'NONG-RIM No, 6' a recommended variety of rice plant for the year of 1969. Main purpose of the experiment are to explore possibilities of; a) ways and means of saving irrigation water and, b) overcoming drought at the same time so that an increaded yield in rice production could be resulted in Specifically, it was tried to determine the effects of the Rotation Irrigation method combined with differentiated thickess of Lining upon the growth and Yield of rice production. Some of the major finding are summarized in the follows. 1) The Different thicknesses show a significant relationship with the weight of 1000 grains. In the case of 3cm Lined plot, the grain weight is 39.0 Grams, the heaviest. Next in order is 6 cm lined plnt, 5 day control plot, 6 day control plot. 2) In rice yield, it is found that there is a considerably moderate signicant relationship with both the different thickness of lining and the number of irrgation, as shown in the table No,7. 3) There is little or no difference among different plot in terms of; a) physical and chemical properties of soil, b) quality of irrgation water, c) climatic condition, and rainfalls. 4) It is found that there is no significant relationship between differences in the method of rotation irrgation and the number of ears per hill because of too much rainydays and low temperature during irrigation season. 5) In uyny1-treated plots, it is shown that there is on difference among different plots, but the irrigation water requirement saved as much as 1/2 to actual irrigation water compare to uncontroled plot. 6) The irrigation water requirement for 48 days is saved as much 67% compared to uncontroled plot, the order are; the 9cm lined plot, the plot of vinyl with no hole, the plot with a hole of $1cm/m^2$ as shows in fig 15. 7) The rate of percolation of 40-30mm/day is decreased to 30-20/day. It is found that the decreasad rate of percolation due to vinyl-cutoff in footpath. 8) The growing condition was fine, and there was no found that decease and lageing as always submerged plot. 9) It is found that it must be constructed irrigation and drainage system, inlet and outlet perpect, respectly, of which could be irrigation water saved and would be inereased the irrigation water temperature.

  • PDF

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF

An Exploratory Study of Hospice Care to Patients with Advanced Cancer (암환자를 위한 호스피스 케어에 관한 탐색적 연구)

  • Park, Hye-Ja
    • The Korean Nurse
    • /
    • v.28 no.3
    • /
    • pp.52-67
    • /
    • 1989
  • True nursing care means total nursing care which includes physical, emotional and spiritual care. The modern nursing care has tendency to focus toward physical care and needs attention toward emotional and spiritual care. The total nursing care is mandatory for patients with terminal cancer and for this purpose, hospice care became emerged. Hospice case originated from the place or shelter for the travellers to Jerusalem in medieval stage. However, the meaning of modem hospice care became changed to total nursing care for dying patients. Modern hospice care has been developed in England, and spreaded to U.S.A. and Canada for the patients with terminal cancer. Nowaday, it became a part of nursing care and the concept of hospice care extended to the palliative care of the cancer patients. Recently, it was introduced to Korea and received attention as model of total nursing care. This study was attempted to assess the efficacy of hospice care. The purpose of this study was to prove a difference in terms of physical, emotional a d spiritual aspect between the group who received hospice care and who didn't receive hospice care. The subject for this study were 113 patients with advanced cancer who were hospitalized in the S different hospitals. 67 patients received hospice care in 4 different hospitals, and 46 patients didn't receive hospice care in another 4 different hospitals. The method of this study was the questionaire which was made through the descriptive study. The descriptive study was made by individual contact with 102 patients cf advanced cancer for 9 months period. The measurement tool for questionaire was made by author through the descriptive study, and included the personal religious orientation obtained from chung(originated R. Fleck) and 5 emotional stages before dying from Kubler Ross. The content ol questionaire consisted in 67 items which included 11 for general characteristics, 10 for related condition with cancer, 13 for wishes far physical therapy, 13 for emotional reactions and 20 for personal religious orientation. Data for this study was collected from Aug. 25 to Oct. 6 by author and 4 other nurse's who received education and training by author for the collection of data. The collected data were ana lysed using descriptive statistics, $X^2-test$, t-test and pearson correlation coefficient. Results of the study were as follows: "H.C Group" means the group of patient with cancer who received hospice care. "Non H.C Group" means the group of patient with cancer who did not receive hospice care. 1. There is a difference between H.C Group and Non H.C Group in term of the number of physical symptoms, subjective degree of pain sensation and pain control, subjective beliefs in physical cure, emotional reaction, help of present emotional and spiritual care from other personal, needs of emotional and spiritual care in future, selection of treatment method by patients and personal religious orientation. 2. The comparison of H.C Group and Non H.C Group 1) There is no difference in wishes for physical therapy between two groups(p=.522). Among Non H.C Group, a group, who didn't receive traditional therapy and herb medicine was higher than a group who received these in degree of belief that the traditional therapy and herb medicine can cure their disease, and this result was higher in comparison to H.C Group(p=.025, p=.050). 2) Non H.C Group was higher than H.C Group in degree of emotional reaction(p=.050). H.C Group was higher than Non H.C Group in denial and acceptant stage among 5 different emotional stages before dying described by Kubler Ross, especially among the patient who had disease more than 13 months(p=.0069, p=.0198). 3) Non H.C Group was higher than H. C Group in demanding more emotional and spiritual care to doctor, nurse, family and pastor(p=. 010). 4) Non H.C Group was higher than H.C Group in demanding more emotional and spiritual care to each individual of doctor, nurse and family (p=.0110, p=.0029, P=. 0053). 5) H.C Group was higher th2.n Non H.C Group in degree of intrinsic behavior orientation and intrinsic belief orientation of personal religious orientation(p=.034, p=.026). 6) In H.C Group and Non H.C Group, the degree of emotional demanding of christians was significantly higher than non christians to doctor, nurse, family and pastor(p=. 000, p=.035). 7) In H.C Group there were significant positive correlations as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and: the degree of intrinsic behavior orientation in personal religious orientation(r=. 5512, p=.000). (2) Between the degree of emotional demandings to doctor, nurse. family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.4795, p=.000). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic: belief orientation in personal religious orientation(r=.8986, p=.000). (4) Between the degree of extrinsic religious orientation and the degree of consensus religious orientation in personal religious orientation (r=. 2640, p=.015). In H.C. Group there were significant negative correlations as following; (1) Between the degree of intrinsic behavior orientation and extrinsic religious orientation in personal religious orientation (r=-.4218, p=.000). (2) Between the degree or intrinsic behavior orientation and consensus religious orientation in personal religious orientation(r=-. 4597, p=.000). (3) Between the degree of intrinsic belief orientations and the degree of extrinsic religious orientation in personal religious orientation(r=-.4388, p=.000). (4) Between the degree of intrinsic belief orientation and the degree of consensus religious orientation in personal religious orientation(r=-. 5424, p=.000). 8) In Non H.C Group there were significant positive correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic behavior orientation in personal religious orientation(r= .3566, p=.007). (2) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.3430, p=.010). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic belief orientation in personal religious orientation(r=.9723, p=.000). In Non H.C Group there were significant negative correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of extrinsic religious orientation in personal religious orientation(r= -.2862, p=.027). (2) Between the degree of intrinsic behavior orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5083, p=.000). (3) Between the degree of intrinsic belief orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5013, p=.000). In conclusion above datas suggest that hospice care provide effective total nursing care for the patients with terminal cancer, and hospice care is mandatory in all medical institutions.

  • PDF

A Study on Differences of Opinions on Home Health Care Program among Physicians, Nurses, Non-medical personnel, and Patients. (가정간호 사업에 대한 의사, 간호사, 진료관련부서 직원 및 환자의 인식 비교)

  • Kim, Y.S.;Lim, Y.S.;Chun, C.Y.;Lee, J.J.;Park, J.W.
    • The Korean Nurse
    • /
    • v.29 no.2
    • /
    • pp.48-65
    • /
    • 1990
  • The government has adopted a policy to introduce Home Health Care Program, and has established a three stage plan to implement it. The three stage plan is : First, to amend Article 54 (Nurses for Different Types of Services) of the Regulations for Implementing the Law of Medical Services; Second, to tryout the new system through pilot projects established in public hospitals and clinics; and third, to implement at all hospitals and equivalent medical institutions. In accordance with the plan, the Regulation has been amend and it was promulgated on January 9,1990, thus establishing a legal ground for implementing the policy. Subsequently, however, the Medical Association raised its objection to the policy, causing a delay in moving into the second stage of the plan. Under these circumstances, a study was conducted by collecting and evaluating the opinions of physicians, nurses, non-medical personnel and patients on the need and expected result from the home health care for the purpose of help facilitating the implementation of the new system. As a result of this study, it was revealed that: 1. Except the physicians, absolute majority of all other three groups - nurses, non-medical personnel and patients -gave positive answers to all 11 items related to the need for establishing a program for Home Health Care. Among the physicians, the opinions on the need for the new services were different depending on their field of specialty, and those who have been treating long term patients were more positive in supporting the new system. 2. The respondents in all four groups held very positive view for the effectiveness and the expected result of the program. The composite total of scores for all of 17 items, however, re-veals that the physicians were least positive for the- effectiveness of the new system. The people in all four groups held high expectation on the system on the ground that: it will help continued medical care after the discharge from hospitals; that it will alleviate physical and economic burden of patient's family; that it will offer nursing services at home for the patients who are suffering from chronic disease, for those early discharge from hospital, or those who are without family members to look after the patients at home. 3. Opinions were different between patients( who will receive services) and nurses (who will provide services) on the types of services home visiting nurses should offer. The patients wanted "education on how to take care patients at home", "making arrangement to be admitted into hospital when need arises", "IV injection", "checking blood pressure", and "administering medications." On the other hand, nurses believed that they can offer all 16 types of services except "Controlling pain of patients", 4. For the question of "what types of patients are suitable for Home Health Care Program; " the physicians, the nurses and non-medical personnel all gave high score on the cases of "patients of chronic disease", "patients of old age", "terminal cases", and the "patients who require long-term stay in hospital". 5. On the question of who should control Home Health Care Program, only physicians proposed that it should be done through hospitals, while remaining three groups recommended that it should be done through public institutions such as public health center. 6. On the question of home health care fee, the respondents in all four groups believed that the most desireable way is to charge a fixed amount of visiting fee plus treatment service fee and cost of material. 7. In the case when the Home Health Care Program is to be operated through hospitals, it is recommended that a new section be created in the out-patient department for an exclusive handling of the services, instead of assigning it to an existing section. 8. For the qualification of the nurses for-home visiting, the majority of respondents recommended that they should be "registered nurses who have had clinical experiences and who have attended training courses for home health care". 9. On the question of if the program should be implemented; 74.0% of physicians, 87.5% of non-medical personnel, and 93.0% of nurses surveyed expressed positive support. 10. Among the respondents, 74.5% of -physicians, 81.3% of non-medical personnel and 90.9% of nurses said that they would refer patients' to home health care. 11. To the question addressed to patients if they would take advantage of home health care; 82.7% said they would if the fee is applicable to the Health Insurance, and 86.9% said they would follow advises of physicians in case they were decided for early discharge from hospitals. 12. While 93.5% of nurses surveyed had heard about the Home Health Care Program, only 38.6% of physicians surveyed, 50.9% of non-medical personnel, and 35.7% of patients surveyed had heard about the program. In view of above findings, the following measures are deemed prerequisite for an effective implementation of Home Health Care Program. 1. The fee for home health care to be included in the public health insurance. 2. Clearly define the types and scope of services to be offered in the Home Health Care Program. 3. Develop special programs for training nurses who will be assigned to the Home Health Care Program. 4. Train those nurses by consigning them at hospitals and educational institutions. 5. Government conducts publicity campaign toward the public and the hospitals so that the hospitals support the program and patients take advantage of them. 6. Systematic and effective publicity and educational programs for home heath care must be developed and exercises for the people of medical professions in hospitals as well as patients and their families. 7. Establish and operate pilot projects for home health care, to evaluate and refine their programs.

  • PDF

Studies on the Durability of Mortars (모르타르의 내구성에 관한 연구)

  • 고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1604-1615
    • /
    • 1969
  • This experiment was carried out as one of the basic studies to improve the acid resistance of concrete and it was conducted to investigate some relations among physical properties such as basorption, ratio of water to cement, compressive strength, density and ratio of mix to weight losses of mortar when exposed to 0.1 N solution of hydrochrolic acid. The results obtained from the limited data secured so far in this experiment are summarized as follows: 1. The specimens used in the experiment were made of 5 cubic centimeters of mortar having such various ratios of mix by weight as 1 : 1, 1 : 3, 1 : 5, 1 : 7, 1 : 10. 2. Physical tests included compressive strengths at 7 days, 28 days, 3 months, and 6 month, and 5 hour boiling absorption test. 3. In acid test, every specimen was immersed into 0.1 N solution of hydrochrolic acid. The specimens exposed to the acid solution were weighed to determine the weight losses of the acid-corroded at one week interval for 7 weeks exposure, and the old acid solutions were also changed to fresh one when weighed the weight losses by acid attack at one week interval. 4. The correlative relations were found among physical properties and they are expressed by certain formulas as follows; i) Relation between ratio of mix and absorption Y = 1.036x + 13.53 where Y: absorption(%) X: ratio of mix ii) Relation between ratio of mix and ratio of water-cement Y = 0.204x + 0.214 where Y: ratio of water-cement. X: ratio of mix iii) Relation between ratio of water-cement and absorption Y = 5.01x + 12.53 where Y: absorption(%). X: ratio of water-cement iv) Relation between density and absorption Y = 50.6 - 0.0176X where Y: absorption(%). X: density($kg/m^3$) v) Relation between density and ratio of water cement Y = 7.2183 - 0.0033X where Y: ratio of water-cement . X: density($kg/m^3$) 5. After completing the acid exposure test the specimens were corroded and , the per cent ranges of weight losses varies from a minimum of 20.4 per cent at a 1 : 1 mix to a maximum of 92.0 per cent at a 1:10 mix 6. The correlative relations of physical properties of mortar to weight losses by acid attak were found and they are also expressed by certain formulas as follows: i) Relation between weight losses and ratio of mix Y = 8.59X + 8.63 where Y: weight losses(%), X: ratio of mix ii) Relation between wieght losses and absorption Y = 0.121x + 12.43 where Y: absorption(%). X: weight losses(%) iii) Relation between weight losses and ratio of w/c Y = 0.0226X + 0.07 where Y: ratio of w/c X: weight losses(%) iv) Relation between weight losses and compressive strength LogY = 3.6097 - 0.05058X + 0.00022$X^2$ where Y: compressive strength ($kg/cm^3$) X: weight losses(%) v) Relation between weight losses and density Y = 2153.1 - 6.62X where Y: density($kg/m^3$) X: weigh losses(%) 7. In order to make better acid resistant mortar, it could be concluded that a 1 : 3 mix or richer mixes, adequate mixing water to minnimize the ratio of water-cement considering the workability, 16 per cent or less absorption by 5 hour boiling water, 1,800 kilogram per cubic meter or denser density by absolute weight base and 200 kilogram per square meter or compressive strength at 20 day, etc are required so as to obtain acid-resistant mortar. In addition to the above, it might be recommonded to select the fine aggregate and to use better equipments such as a mechanical vibrator, a mechanical mixer etc. in concrete manufacturing works.

  • PDF

Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics (유역특성에 의한 합성단위도의 유도에 관한 연구)

  • 서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF

Experiment for Various Soils on Economic Duty of Water in Paddy Fields (각종토성별 경제적용수량 결정시험연구)

  • Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1561-1579
    • /
    • 1969
  • In Korea, the duty of water in paddy fields was measured at the Agricultural Experimental Station in Suwon about 60 years ago. After that time some testing has been made in several places, but the key points in its experiment were the water depth of evapo-transpiration. Improved breeds, progress in cultivation and management techniques as well as development of measuring apparatus in recent years have necessitated the review of the duty of water in paddy fields. The necessity of reviewing the conventional methods has become even more important, as no source of information has been made available through survey of water utilization on a soil use basis which requires data on peculiar features of the water depth of evapo-transpiration. For example, the duty of water in paddy field is largely affected by the water depth of evapo-transpiration in connection with the wetted paddy field, whereas in connection with the normal paddy fields without this characteristic the vertical percolation become the predominant factor in measuring the decreasing depth of water. Therefore, it becomes important. that not only the water depth of evapotranspiration but also the vertical percolation process should also be observed in order to arrive at a realistic conclusion. As the vertical percolation has aclose relationship to the height of the underground water, the change of the latter can be measured. As the conclusion of this experiment, the following subjects are indicated. 1. In order to determine the economic duty of water in paddy fields on a basis of varying soil features, the varying soil features in the benifited area should be investigated thoroughly. The water depths of evapo-transpiration(ET) ratio to evaporation in the evaporator(V) on a basis of the varying soil features are as follows: clay loam ET/V = 1.11, loam ET/V = 1.64, sandy loam ET.V = 1.63 2. The decreasing depth of water consists of the water depth of evapotranspiration, the vertical per colation and the percolation of foot path. Among these three, the percolation of foot path can be utilized again. 3. As the result of this experiment, it shows the decreasing depth of water as follows. clay loam 9.3 mm/day, loam 13.5mm/daty, sandy loam 15.3mm/day 4. On a basis of the varying soil features and the height of the underground water, the vertical percolation varies. 5. The change of the vertical percolation on a basis of the varying soil features shows as follows: clay loam $1{\sim}2$ mm/day, loam $2{\sim}3$mm/day, sandy loam $3{\sim}4$mm/day 6. The level of the underground water changes sensibly by priority of clay loam, loam, sandy loam. When it rains, the level of the underground water rises fast and falls down slowly. 7. The level of the underground water changes within the scope of 25cm 8. The transpiration ratio is given in table 8 and their value are as follows: clay loam 168.8, loam 255.6, sandy loam 272.5

  • PDF

Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea (한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I))

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

Analysis of Success Cases of InsurTech and Digital Insurance Platform Based on Artificial Intelligence Technologies: Focused on Ping An Insurance Group Ltd. in China (인공지능 기술 기반 인슈어테크와 디지털보험플랫폼 성공사례 분석: 중국 평안보험그룹을 중심으로)

  • Lee, JaeWon;Oh, SangJin
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.3
    • /
    • pp.71-90
    • /
    • 2020
  • Recently, the global insurance industry is rapidly developing digital transformation through the use of artificial intelligence technologies such as machine learning, natural language processing, and deep learning. As a result, more and more foreign insurers have achieved the success of artificial intelligence technology-based InsurTech and platform business, and Ping An Insurance Group Ltd., China's largest private company, is leading China's global fourth industrial revolution with remarkable achievements in InsurTech and Digital Platform as a result of its constant innovation, using 'finance and technology' and 'finance and ecosystem' as keywords for companies. In response, this study analyzed the InsurTech and platform business activities of Ping An Insurance Group Ltd. through the ser-M analysis model to provide strategic implications for revitalizing AI technology-based businesses of domestic insurers. The ser-M analysis model has been studied so that the vision and leadership of the CEO, the historical environment of the enterprise, the utilization of various resources, and the unique mechanism relationships can be interpreted in an integrated manner as a frame that can be interpreted in terms of the subject, environment, resource and mechanism. As a result of the case analysis, Ping An Insurance Group Ltd. has achieved cost reduction and customer service development by digitally innovating its entire business area such as sales, underwriting, claims, and loan service by utilizing core artificial intelligence technologies such as facial, voice, and facial expression recognition. In addition, "online data in China" and "the vast offline data and insights accumulated by the company" were combined with new technologies such as artificial intelligence and big data analysis to build a digital platform that integrates financial services and digital service businesses. Ping An Insurance Group Ltd. challenged constant innovation, and as of 2019, sales reached $155 billion, ranking seventh among all companies in the Global 2000 rankings selected by Forbes Magazine. Analyzing the background of the success of Ping An Insurance Group Ltd. from the perspective of ser-M, founder Mammingz quickly captured the development of digital technology, market competition and changes in population structure in the era of the fourth industrial revolution, and established a new vision and displayed an agile leadership of digital technology-focused. Based on the strong leadership led by the founder in response to environmental changes, the company has successfully led InsurTech and Platform Business through innovation of internal resources such as investment in artificial intelligence technology, securing excellent professionals, and strengthening big data capabilities, combining external absorption capabilities, and strategic alliances among various industries. Through this success story analysis of Ping An Insurance Group Ltd., the following implications can be given to domestic insurance companies that are preparing for digital transformation. First, CEOs of domestic companies also need to recognize the paradigm shift in industry due to the change in digital technology and quickly arm themselves with digital technology-oriented leadership to spearhead the digital transformation of enterprises. Second, the Korean government should urgently overhaul related laws and systems to further promote the use of data between different industries and provide drastic support such as deregulation, tax benefits and platform provision to help the domestic insurance industry secure global competitiveness. Third, Korean companies also need to make bolder investments in the development of artificial intelligence technology so that systematic securing of internal and external data, training of technical personnel, and patent applications can be expanded, and digital platforms should be quickly established so that diverse customer experiences can be integrated through learned artificial intelligence technology. Finally, since there may be limitations to generalization through a single case of an overseas insurance company, I hope that in the future, more extensive research will be conducted on various management strategies related to artificial intelligence technology by analyzing cases of multiple industries or multiple companies or conducting empirical research.

Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve (단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.7 no.1
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF