• Title/Summary/Keyword: Korean Civil Code

Search Result 412, Processing Time 0.03 seconds

Reliability Analysis of Design Wind Load Combination for Support Structures of Subsidiary Road Facilities (도로 부대시설 지주구조물 설계를 위한 풍하중조합의 신뢰도 분석)

  • Kim, Gneok;Ahn, Sang-Sup;Kim, Ho-Kyung;Cho, Kyung-Sik;Paik, Inyeol
    • International Journal of Highway Engineering
    • /
    • v.19 no.4
    • /
    • pp.27-36
    • /
    • 2017
  • PURPOSES : The purpose of this study is to perform a reliability analysis of the proposed wind load combination which governs the design of support structures of subsidiary road facilities, and to evaluate whether the target reliability of the design is satisfied. METHODS : The statistical estimation method is applied and the design period of the support structure is used to obtain the statistical property of the wind load. In addition, the statistical properties of the strength of support structures are obtained from a literature review and simulation study. Actual support structures are designed by the proposed load combination and are used as the examples to examine if the target reliability is obtained. RESULTS : The result of the reliability analysis performed by using the statistical properties of load and resistance for the support structure in this study indicates that the proposed wind load combination satisfied the target reliability index of the design. Also, the convenience of the design is achieved by adopting the same design wind velocity given in the bridge design code by applying the wind velocity ratio defined for the design period of the support structure. CONCLUSIONS : It is presented that the design using the wind load combination proposed in this study achieved the target reliability index and the design wind load for different design periods can be conveniently defined by applying the velocity ratio proposed in this study.

Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank (지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석)

  • Yun, Jang Hyeok;Kang, Tae Won;Yang, Hyunik;Jeon, Jong-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part II: Structural damage and vibrations

  • Qu, Y.G.;Wu, H.;Xu, Z.Y.;Liu, X.;Dong, Z.F.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.397-416
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part II, based on the verified finite element (FE) models of aircrafts Airbus A320 and A380, as well as the NPP containment and auxiliary buildings in Part I of this paper, the whole collision process is reproduced numerically by adopting the coupled missile-target interaction approach with the finite element code LS-DYNA. The impact induced damage of NPP plant under four impact locations of containment (cylinder, air intake, conical roof and PCS water tank) and two impact locations of auxiliary buildings (exterior wall and roof of spent fuel pool room) are evaluated. Furthermore, by considering the inner structures in the containment and raft foundation of NPP, the structural vibration analyses are conducted under two impact locations (middle height of cylinder, main control room in the auxiliary buildings). It indicates that, within the discussed scenarios, NPP structures can withstand the impact of both two aircrafts, while the functionality of internal equipment on higher floors will be affected to some extent under impact induced vibrations, and A380 aircraft will cause more serious structural damage and vibrations than A320 aircraft. The present work can provide helpful references to assess the safety of the structures and inner equipment of NPP plant under commercial aircraft impact.

An Overview of the ADR Act of 2004 in the Philippines - Focused on the Adoption of the UNCITRAL Model Law - (필리핀의 2004년 대체적 분쟁해결법 소고 - UNCITRAL 모범법의 수용과 관련하여 -)

  • Kim, Sun-Jeong
    • Journal of Arbitration Studies
    • /
    • v.19 no.2
    • /
    • pp.197-227
    • /
    • 2009
  • This study describe the brief history and current statutes of Philippine arbitration. The practice of arbitration in the Philippines can be traced as far back as the barangay. From 1521, Spanish Civil Code became effective in the Philippines. During this period, the Supreme court was discouraged by the tendency of some courts to nullify arbitration clauses on the ground that the clauses ousted the judiciary of its jurisdiction. According to the growing need for a law regulating arbitration in general was acknowledged when Republic Act No.876(1953), otherwise known as the Arbitration Law, was passed. In 1958, the Philippines became a signatory to the New York Convention and in 1967 the said Convention was ratified. But no legislation has been passed. As a consequence, foreign arbitral awards have sometimes been deemed only presumptively valid, rather than conclusively valid. Fifty years after, the Philippine Congress enacted, Republic Act No. 9285, otherwise know as the Alternative Dispute Resolution Act of 2004. The enactment was the Philippines solution to making arbitration an efficient and effective method specially for international arbitration. To keep pace with the developments in international trade, ADR Act of 2004 also ensured that international commercial arbitration would be governed by the UNCITRAL Model Law on International Arbitration and also fortified the use and purpose of the New York Convention by specifically mandating. If the international commercial arbitration will be revitalization in the near future in the Philippine, it will be shown that the model law's comprehensive provisions will give the beat framework for arbitration.. The writer expect that Philippines continues in its effort to be the premier site for international arbitration in Southeast Asia.

  • PDF

A Legal Study on the Standard for Conformity of the Goods in the International Sale of Goods (국제물품매매계약상(國際物品賣買契約上) 물품일치성(物品一致性)의 기준(基準)에 관한 법리적(法理的) 고찰(考察))

  • Song, Myeong-Bok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.12
    • /
    • pp.133-162
    • /
    • 1999
  • The international sale transaction is in essence a sale of goods and presents all those commercial and legal problems in any sale of goods. As a result, A International sales contract imposes several duties on the parties : the seller must deliver the goods and transfer ownership in them, while the buyer must pay the price and take delivery of the goods. However, there are several problems which impede a active transaction between seller and buyer who have their places of business in other countries each other. Therefore, It is necessary to provide the concept on the conformity of goods in the Int'l Sale of Goods. Especially, In our consideration for the point of time when defects occurs, the existence of non-conformity of goods should be judged on the basis of time of delivery rather than time of contract. Moreover, The burden of proof about nonconformity of goods is another fact which make an international dispute between the contractual parties in an international trade. Thus, The consistency in the interpretation of law must be maintained betweened the warranty and seller's liability. In the Uniform Commercial Code and UN Convention, non-conformity of contract is made of contract liability. And in our civil and commercial law provisions of warranty should be understand as the special ones of the provisions of general non-performance of obligation liability. As a result, More concrete study of them is required because they may have a great influence especially on international trade. As a result, We should be our best in finding a helpful and systematic structure that the dualistic structure of nonperformance of obligation liability and warranty liability must be unified by studying the theories of English and American warranty and our legal system, as well as international practice and usage being used in an international trade.

  • PDF

Analysis of Performance-based Design Guides of Smoke Control System (성능위주 연기제어 설계지침 분석)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.6-13
    • /
    • 2016
  • With regard to smoke control system, the design guidelines of smoke exhaust for accommodation and smoke control for evacuation stairs and vestibule has been proposed domestically, but after reviewing the applicability to modern buildings that tend to be larger, higher and complex, a smoke control system according to domestic design guidelines might have difficulty in securing the safety from smoke in a fire. Therefore, it is necessary to adopt the performance-based design of a smoke control system that can enhance the safety and integrate the smoke control functions and design depending on the characteristics of fire and building structure in the case of fire in a large, high-rise, and complex building. This study analyzed the domestic design guidelines of a smoke control system and this paper proposes the part requiring improvement, and examines the legal system and guidelines on performance-based design of smoke control system in foreign countries.

A Study on the Enhancement of Fire Resistance Function in Primary Structure Department of Building Type Traditional Market (건물형 전통시장 화재발생시 피난안전성 확보를 위한 규모별 주요구조부 내화보강 연구)

  • Jang, Hye-Min;Hwang, Jung-Ha
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.87-95
    • /
    • 2020
  • This study evaluates the safety of an asylum through a fire simulation of building Type traditional markets. We derive the building's indoor temperature, use the observed variation in temperature gradient to calculate the temperature of the main structure, and finally compares the time required to attain the limit temperature of the structure its time of escape. To ensure improved security of the asylum, the government has proposed a fire-resistance improvement plan for the major structural parts of buildings are not safe with thickness of 0.01 m and 0.035 m. F.ire-resistance reinforcement for small - and medium-sized vehicles is more than 0.025 m, in thickness; moreover safety can be ensured for medium and large-sized vehicles fire using fire resistant reinforcement of over 0.035 m. Accordingly, in order to ensure the safety of an asylum, fire-resistant reinforcement measures may be considered.

Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (I- Analysis of Field Testing of Cable Supported Bridge) (마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(I-실 교량 실험 결과 분석))

  • Gil, Heungbae;Park, Sun Kyu;Han, Kyoung Bong;Yoon, Wan Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.157-167
    • /
    • 2020
  • In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the "Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges." Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.

A Study on the Necessity of Limitation for Legal Liability in Marine Accidents (해양사고에 있어서 책임귀속의 제한 필요성에 관한 연구)

  • Ji, Sang-Won
    • Journal of Navigation and Port Research
    • /
    • v.34 no.3
    • /
    • pp.251-255
    • /
    • 2010
  • A marine accident is caused various legal liability such as compensation for damages on civil law, responsibility on the Criminal Code and administrative sanctions. The results occurred by any acts is not connected directly to the legal responsibility. As a prior condition for these legal liabilities, it is required the causation between the act caused and the occurrence of the effect. It is very difficult to find out the cause in marine accidents, because of trouble of a proof security, the place occurred, time difference between accident and investigation point of time etc.. However, finding out the correct cause is an element important to prevent similar accident and to determine the liability reverted. The logical concept of the causation is not limited, but there is early necessity to limit it in the liability reverted. Therefore, this study aims to suggest reasonable standard to determine liability reverted in marine accidents.

The Improvement and Problem about Housing Lease Protection Act Article 9 in the Information Society (정보사회에 있어서 주택임대차보호법 제9조의 문제점에 대한 개선방안)

  • Park, Jong-Ryeol
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.61-67
    • /
    • 2015
  • In order to ensure the housing stability of homeless people who living in the information society, the Korean Housing Lease Protection Act was enacted as a special law of Civil Code in March 5, 1981, Law No. 3379. And until January 6, 2015 there were 15 times revisions. In the meantime, many issues have been resolved by legal revisions through several times however, it is true that many problems are exposed after enforcement because processing without sufficient review of legislation. Among them, at the 1st revision in 1983 the purpose of Article 9 for lease succession was admitting succession to a spouse who has no inheritance rights. Then it can protect common-law relationship and on the other hand protect the residential life of a spouse. But many questions have been raised. Therefore, in this paper, analyze the problem of lease succession carefully, proposes an improvement to contribute to the residential stable livelihood.