• 제목/요약/키워드: Korean Building Code(KBC2009)

검색결과 11건 처리시간 0.02초

평면 비정형 건물의 설계편심과 지진 손상도의 상관관계에 관한 연구 (A Study on the Relationship between Earthquake Damage and the Design Eccentricity of Building with Planar Irregularity)

  • 이광호;정성훈
    • 한국지진공학회논문집
    • /
    • 제17권5호
    • /
    • pp.237-243
    • /
    • 2013
  • In the Korean Building Code (KBC), the Design Eccentricity involves the torsional amplification factor (TAF), and the inherent and accidental eccentricities. When a structure of less than 6-stories and assigned to seismic design category C or D is designed using equivalent static analysis method, both KBC-2006 and KBC-2009 use the TAF but apply different calculation methods for the of design eccentricity. The design eccentricity in KBC-2006 is calculated by multiplying the sum of inherent eccentricity and accidental eccentricity at each level by a TAF but that in KBC-2009 is calculated by multiplying only the accidental eccentricity by a TAF. In this paper, the damage indices of a building with planar structural irregularity designed by different design eccentricities are compared and the relationship between the earthquake damage and design eccentricity of the building is evaluated. On the basis of this study, the increment of design eccentricity results in the decrement of final eccentricity and global damage index of structure. It is observed that design eccentricity in KBC-2006 reduces the vulnerability of torsional irregular building compared to design eccentricity in KBC-2009.

KBC 풍하중 기준 분석을 통한 풍하중의 한국형 BIM 적용방안에 관한 사례연구 (A Case Study on Application Method of Korean Building Information Modeling (BIM) through the Analysis of Wind Load Criteria based on Korean Building Code (KBC))

  • 조영상;신태송;홍성욱;배준서;김유리
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2009년도 정기 학술대회
    • /
    • pp.509-512
    • /
    • 2009
  • 본 논문에서는 KBC(Korean Building Code)와 IBC(International Building Code)의 풍하중 기준의 비교 분석을 통하여, BIM 프로세스 기반의 구조해석 및 설계 프로그램에서 풍하중 산정 시 국내 건축구조설계기준(KBC)을 적용하기 위한 방안을 제시하는 것을 목적으로 한다. 현재 BIM 기반 구조해석 및 설계 프로그램 중에는 한국구조설계기준(KBC)에 부합하는 풍하중 산정이 가능한 프로그램이 존재하지 않는다. 구조설계 기준에서 특히 풍하중 산정 방법은 기준 및 지역에 따른 산정 방법에 차이가 있기 때문에, 구조설계의 안전성을 높이고 한국 실정에 맞는 건축물의 설계를 위해서 KBC 기준의 적용이 필요하다. 본 연구에서는 IBC와 KBC 내의 풍하중 산정 방법의 차이점을 비교 분석하고, 실제 사례연구를 통하여 풍하중 산정의 차이를 확인한다. KBC 기준 풍하중 산정 결과를 구조해석 및 설계 프로그램에 적용하기 위한 방법으로써 외부 프로그램을 활용하며 외부 프로그램에서 산정한 풍하중을 다시 구조해석 및 설계 프로그램 상에 입력하여 구조해석을 수행함으로써 KBC 기준 풍하중의 적용을 통한 한국형 BIM 구조해석 및 설계의 방안을 제시한다.

  • PDF

KBC 비구조요소 내진설계 하중 (KBC Seismic Design Force for Nonstructural Element)

  • 김대곤
    • 한국공간구조학회논문집
    • /
    • 제14권1호
    • /
    • pp.77-84
    • /
    • 2014
  • Simple 3, 10, and 30-story buildings with a nonstructural element which is located at roof or near the middle of the building height are selected. Based on 2009 Korean Building Code, the seismic design force applied at the nonstructural element is evaluated. Response spectrum analysis is conducted with the design response acceleration spectrum of 2009 Korean Building Code and the analytical response is compared with the seismic design force from the Code. Furthermore, an artificial earthquake based on Korean design response acceleration spectrum and the 50% intensity of El Centro earthquake, which can be considered as the maximum future earthquake possibly occurring in Korea, are selected to conduct time history analysis. When the period of the nonstructural element is shorter than 0.06 second or longer than that of the 1st period of each building, the Code equations of seismic design force for nonstructural element seems to be appropriate. However, the period of the nonstructural element is close to the one of the building's higher mode periods including the 1st period, seismic force of the nonstructural element might exceed the Code specified seismic design force.

해안인접지역 기초 구조물콘크리트의 내염해 성능 평가 -건축구조기준과의 성능비교- (An Evaluation on the Chloride Resistance of Concrete Footing at Coastal Area -Comparision of Performance in Korea Building Code(KBC)-)

  • 박용규;윤기원;김현우;김용로;송영찬
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2016
  • In this paper, the increase in chloride resistance of footing concrete at coastal area was evaluated by replacement of Mineral Admixture. In KBC 2009, the footing concrete's minimum specific concrete strength at coastal area is determined to 35MPa. However, this is criteria only based on the strength aspect. Thus, it is not considered to increase the chloride resistance by replacement of Mineral Admixture. According to the test results of chloride ions penetration resistance, 35MPa class concrete with OPC 100% shown inaccessible state. Low-strength (24~30MPa class) concretes with Mineral Admixture, however, presented better performances. In addition, chloride diffusion coefficient tests showed identical appearance. Therefore, the current KBC's chloride resistance criteria based on only concrete strength has to review for the reason it can cause many problems (ex. cost increases by growing concrete strength and the environmental issues by a lot of cement use).

  • PDF

비구조요소의 내진 설계를 위한 기존 층응답스펙트럼의 평가 (A Study on Evaluation of Floor Response Spectrum for Seismic Design of Non-Structural Components)

  • 최경석;이원호;양원직;김형준
    • 한국지진공학회논문집
    • /
    • 제17권6호
    • /
    • pp.279-291
    • /
    • 2013
  • The seismic damage of non-structural components, such as communication facilities, causes direct economic losses as well as indirect losses which result from social chaos occurring with downtime of communication and financial management network systems. The current Korean seismic code, KBC2009, prescribes the design criteria and requirements of non-structural components based on their elastic response. However, it is difficult for KBC to reflect the dynamic characteristics of structures where non-structural components exist. In this study, both linear and nonlinear time history analyses of structures with various analysis parameters were carried out and floor acceleration spectra obtained from analyses were compared with both ground acceleration spectra used for input records of the analyses and the design floor acceleration spectrum proposed by National Radio Research Agency. Also, this study investigates to find out the influence of structural dynamic characteristics on the floor acceleration spectra. The analysis results show that the acceleration amplification is observed due to the resonance phenomenon and such amplification increases with the increase of building heights and with the decrease of structure's energy dissipation capacities.

HAZUS틀을 사용한 서울시 강남구의 건축물 지진피해에 따른 직접적 경제손실 예측 (Earthquake Direct Economic Loss Estimation of Building Structures in Gangnam-Gu District in Seoul Using HAZUS Framework)

  • 정기현;이한선;권오성;황경란
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.391-400
    • /
    • 2016
  • For earthquake loss estimation of building structures in Gangnam-Gu district in Seoul, three scenario earthquakes were selected by comparison of the response spectra of these scenario earthquakes with the design spectrum in Korean Building Code (KBC 2009), and then direct losses of the building structures in the Gangnam-Gu district under each scenario earthquake are estimated. The following conclusions are drawn from the results of damage and loss in the second scenario earthquake, which has a magnitude = 6.5 and epicentral distance =15 km: (1) The ratio of building stocks undergoing the extensive and complete damage level is 40.0% of the total. (2) The amount of direct economic losses appears approximately 19 trillion won, which is 1.2% of the national GDP of Korea. (3) About 25% of high-rise (over 10-story) RC building wall structures, were inflicted with the damage exceeding moderate level, when compared to 60% of low-rise building structures. (4) From the economical view point, the main loss, approximately 50%, was caused by the damage in the high-rise RC wall building structures.

특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 비선형 내진거동 해석 (Analysis of Nonlinear Seismic Behavior of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details)

  • 윤성준;이기학;천영수;김태완
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.43-51
    • /
    • 2013
  • In this paper, analytical models for reinforced concrete shear wall systems designed based on Korean Building Code (KBC2009) are proposed, which have special and semi-special seismic details and are compared with experimental results for a verification of analytical models. In addition, semi-special seismic details aimed to improve constructability and enhance economic efficiency were proposed and evaluated. The analytical models were performed based on nonlinear static and dynamic analysis. Through the nonlinear analyses, two seismic details showed the similar seismic behavior from the cyclic test and the analytical models for the two different seismic details represented the behavior in terms of the initial stiffness, maximum strength and strength degradation. And newly proposed seismic details(semi-special) provided with similar hysterestic behavior as well as the maximum drift.

GIS를 이용한 고유주기에 따른 지진응답계수 분석 (Analysis of Seismic Response Coefficient by Fundamental Period using Geographic Information System)

  • 서은수;최세휴
    • Spatial Information Research
    • /
    • 제20권1호
    • /
    • pp.39-45
    • /
    • 2012
  • 지진하중을 받는 건축물의 반응은 고유주기에 따라 다르게 나타난다. 국내 건축구조기준에서는 고유주기에 따른 지진응답계수를 규정함으로써 건축물의 내진설계를 하도록 하고 있다. 최근 많은 연구자들에 의하여 건축물의 고유주기, 지진응답계수에 대한 많은 연구가 이루어졌으나, 지리정보시스템(GIS)을 이용한 내진설계에 관한 연구는 미흡한 실정이다. 따라서 본 연구에서는 입체적인 3차원 공간에서 고유주기에 따른 지진응답계수를 비교 및 검토함으로써 구조물의 내진성능에 대한 분석을 효율적으로 평가할 수 있으며, 지리정보시스템(GIS)을 이용하여 합리적인 내진설계를 할 수 있는 기초 자료로 사용될 것이라고 기대된다.

특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 내진성능평가 (Seismic Performance Evaluation of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details)

  • 오해철;이기학;천영수;김태완
    • 한국지진공학회논문집
    • /
    • 제18권4호
    • /
    • pp.181-191
    • /
    • 2014
  • This research presents the nonlinear analysis model for reinforced concrete shear wall systems with special boundary elements as proposed by the Korean Building Code (KBC, 2009). In order to verify the analysis model, analytical results were compared with the experimental results obtained from previous studies. Established analytical model was used to perform nonlinear static and dynamic analyses. Analytical results showed that the semi-special shear wall improved significantly the performance in terms of ductility and energy dissipation as expected based on previous test results. Furthermore, nonlinear incremental dynamic analysis was performed using 20 ground motions. Based on computer analytical results, the ordinary shear wall, special shear wall and newly proposed semi-special shear wall systems were evaluated based on the methods in FEMA P965. The results based on the probabilistic approaches accounting for inherent uncertainties showed that the semi-special shear wall systems provide a high capacity/demand (ACMR) ratio owing to their details, which provide enough capacity to sustain large inelastic deformations.

고강도 원형강관의 직각방향 거셋플레이트 접합부 실험 및 해석 (Test and Analysis on the Transverse Gusset Plate Connection to Circular Hollow Section(CHS) of High Strength)

  • 이수헌;신경재;이희두;김우범
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.163-173
    • /
    • 2012
  • 원형강관의 접합부는 다양한 상세를 가지고 있으며 접합부가 항복에 이를 경우 복잡한 국부변형을 유발한다. 이러한 접합부의 국부변형을 고려한 단순화된 설계식의 제안은 매우 어려운 문제이다. 원형강관접합부 설계를 위한 현행 한국구조기준(KBC 2009)에서는 AISC의 설계식과 매우 유사한 단순화된 설계식을 제시하고 있다. 현행 설계식은 원형강관 부재의 재질에 대하여 항복강도는 최대 360MPa 항복비는 0.8로 각각 제한하고 있어서 구조기준에서 제한하는 최대항복강도 이상의 강재를 사용할 경우에는 유사 상세접합부를 대상으로 구조실험이나 합리적인 해석 등을 통하여 안전성을 검증한 후 사용하도록 하고 있다. 본 논문에서는 고강도강재(HSB600)와 일반구조용강재 (SS400)를 이용한 원형강관-직각방향 거셋플레이트 접합부에 횡력(수평력)이 작용하는 실험과 정밀모델 유한요소해석을 실시하였다. 유한요소해석 및 실험결과를 현행 설계식과 비교분석하여 향후 접합부 설계식의 개정에 기초적 자료로 사용될 수 있을 것이다.