• Title/Summary/Keyword: Korea mode

Search Result 8,519, Processing Time 0.041 seconds

Phase Separation Algorithm for Ex-core Neutron Signal Analysis

  • Jung, Seung-Ho;Kim, Tae-Ryong
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.399-405
    • /
    • 1997
  • In this study a new phase separated spectral analysis algorithm is proposed to identify CSB vibration mode directly from ex-core neutron signals. Ex-core neutron signals can be decomposed into the global, core support barrel (CSB) beam mode, and CSB shell mode components by the new phase separation algorithm based on the characteristics of Fourier transform. By using the proposed algorithm and the conventional spectral analysis the vibration mode of the CSB and the fuel assembly of Ulchin-1 NPP were identified from measured ex-core neutron signals.

  • PDF

The study on Failover subsystem of SCADA system (SCADA 시스템의 FAILOVER SUBSYSTEM에 관한 연구)

  • Kim, Young-Tae;Cho, Nam-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.835-837
    • /
    • 1999
  • Failover subsystem of computer consists four modes In this paper, These modes will be discussed in more detail. - dual computer mode - failover mode - single computer mode - standby synchronization mode we have suggested the method of dual/redunancy configulation of server computer. Failover is activated by the standby computer, active computer receives a failover request across the inter-computer link immediatly. The active computer controls the scada system and maintains the current state in it's data base and channel system safety.

  • PDF

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

Success Factors of Mobile Internet Business: A Case of NTT DoCoMo`s i-mode (모바일 인터넷 비즈니스의 성공전략에 관한 연구 -NTT DoCoMo의 i-mode를 중심으로-)

  • 김광희
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2000.11a
    • /
    • pp.235-244
    • /
    • 2000
  • 본 논문에서는 모바일 인터넷으로 대표되는 제2차 IT혁명에서 세계 주도권을 노리고 있는 일본에 초점을 맞춘다. 특히 NTT DoCoMo의 i-mode 서비스, 즉$\ulcorner$휴대전화와 인터넷의 성공적 융합$\lrcorner$이라 할 수 있는 "모바일 인터넷"에 대한 분석과 성공전락 등을 통하여 향후 한국의 모바일 인터넷이 추구해야 할 방향성과 그 과제에 대하여 살펴보기로 한다.

  • PDF

Analysis of Wide Band Annular Ring Microstrip Patch Antenna (광대역 Annular Ring 마이크로스트립 패치 안테나의 해석)

  • Seo, Chul-Hun;Kim, Hyeong-Seok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.13-21
    • /
    • 2003
  • This paper presents the analysis of the mode characteristics of an annular ring microstrip patch antenna for circular polarization with attachment mode using method of moments in the spectral domain. For a probe excitation, the input impedance are obtained by using the single mode approximation for both the $TM_{11}$ and $TM_{12}$ modes and compared with those by Vector Hankel Transform. While the $TM_{11}$ mode has a high Q, it is a poor radiating mode; the $TM_{12}$ mode is more suitable for antenna applications. It is also shown that the bandwidth of the $TM_{12}$ mode is wider than that of the $TM_{11}$ mode in terms of axial ratio for circular polarizatio

  • PDF

A Study of Implementation of a Firewall that Using the both Gateway Mode and Bridge Mode (게이트웨이 모드와 브리지 모드를 동시에 지원하는 침입차단시스템 구현에 관한 연구)

  • 박창서
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.967-969
    • /
    • 2003
  • Because of the rapid growth of Internet, the firewall is generally used to protect the network sorority. The firewall on Linux or FreeBSD Kernal, which is widely used, supports either Gateway or Bridge Mode. In this study, we present the firewall which supports simultaneously Gateway and Bridge Mode. For the application service, it is suggested that the firewall which has excellent expandability ran construct a network without another proxy.

  • PDF

A Seamless and Autonomous Mode Transfer Method of Grid-connected Inverter in Microgrid (마이크로그리드에서 계통연계 인버터의 자율적이며 끊김없는 모드전환 기법)

  • Park, Sung-Youl;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.349-355
    • /
    • 2019
  • A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at mode change and during clearing time while detecting unintentional islanding. This study proposes a mode transfer method for a grid-connected inverter with critical loads. The proposed method, which integrates the grid-connected and islanded mode control loops into one control block, provides an autonomous and seamless mode transfer from the current control to the voltage control. Therefore, the proposed scheme can supply a stable voltage to critical loads at mode change and during clearing time. Experimental results are provided to validate the proposed method.

The Contribution of the S&T-Centered Research Universities on the Regional Innovation: Based on Mode 1 and Mode 2 Knowledge Performances (과학기술특성화대학의 지역혁신 연계성 분석: 모드 1과 모드 2 지식성과를 중심으로)

  • Nha, Chie-Soo;Lee, Jung-Soo;Park, Jaemin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.114-127
    • /
    • 2016
  • The competition among nations has been extended to competition between localities, and the importance of knowledge activities in local areas is being emphasized. To contribute to the nurturing of highly qualified professionals and the development of local industry, the Korean government established the S&T-centric research universities including KAIST in 5 local areas. These S&T-centric research universities are top notch research centers and educational environments in Korea. However, it has been pointed out that their ability to act as local innovation hubs is limited. Accordingly, this study conducted an empirical analysis on the outcomes of the S&T-centric research universities by dividing them into two categories, Mode 1 and Mode 2, and comparing them with those of other general universities. It was found that the outcomes of the S&T-centric universities were higher in Mode 1, but lower in Mode 2, than those of the general universities. Furthermore, the S&T-centric universities are not connected very much to the region's specialized industries. It was difficult to find any evidence that the S&T-centric universities differ from the other universities in terms of their outcomes or activities as they were initially envisaged.

Characteristics and Paleoceanographic Implications of Grain-size Distributions of Biogenic Components in Sediments from the South Korea Plateau (East Sea) (동해 남한국대지 퇴적물의 생물기원 성분 입도 분포의 특성과 고해양학적 의미)

  • Jang, Jun-Ho;Bahk, Jang-Jun;Kim, Eun-Jung;Um, In-Kwon
    • Ocean and Polar Research
    • /
    • v.42 no.3
    • /
    • pp.249-261
    • /
    • 2020
  • This study details grain-size distributions (GSDs) of carbonate and biogenic opal fractions of the sediments retrieved from the South Korea Plateau in the East Sea and draws paleocanographic implications from them. The opal-fraction GSDs show fine modes of 10.3 ㎛ and coarse modes of 102.5 ㎛ on average. The fine-mode grains of opal fractions mainly consist of small diatoms and radiolarians including their broken frustules, while the coarse-mode grains are mostly comprised of large warm-water diatoms and radiolarians. Significant positive correlation between opal contents and abundances of the coarse-mode GSDs in the total GSDs suggests that the abundances of the coarse-mode GSDs were controlled by the increased surface productivity of warm-water diatoms during interglacial stages. The carbonate-fraction GSDs show fine modes of 2.4 ㎛ and coarse modes of 99.1 ㎛ on average. The fine-mode grains mainly consist of coccolithophores, while the coarse-mode grains are mostly comprised of intact or broken planktonic foraminifera. The abundances of coarse-mode and fine-mode GSDs were not correlated with carbonate contents, suggesting a complex control exerted by both the degree of carbonate dissolution and the productivity of coccolithophores on the carbonate-fraction GSDs.

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF