• Title/Summary/Keyword: Korea Design Standard

Search Result 3,774, Processing Time 0.032 seconds

A Study on the Score of Issues by Certification Grade in the G-SEED for Office Buildings (업무용 건축물의 녹색건축 인증등급별 평가항목 득점에 관한 연구)

  • Hwang, Seonyoung;Tae, Choonseob;Shin, Ucheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.9-18
    • /
    • 2016
  • G-SEED(Green Standard for Energy and Environmental Design) is the certification system to evaluate environmental friendliness of buildings for the purpose of reducing environmental burden generated from the entire process of buildings, which is classified into 4 grades according to the evaluated score. Green building certification rule regulate to get over green 2nd grade for the public office buildings of $3000m^2$ or more. However, detailed measures on the applied level of each issue to obtain targeted certification grade have not been prepared yet. For each issue, the score distribution and the ratio of score in proportion to credit were analyzed by certification grade for office buildings which get the G-SEED certification. And applied level of issues were presented for each certification grade.

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

Prediction of Sediment according to Type of Rural Canal (농촌용 수로의 유형에 따른 토사 퇴적량 예측)

  • Song, Chang Seob;Lim, Seong Yoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.121-128
    • /
    • 2014
  • Development of the economic methods and the design of the standard sections needs the more project fund and land than ever leads to the objection of enlarging canal arrangement to need economic construction method development and standard design for supporting it. The objective of this study was to evaluate the performance of selected sediment reduction methods to reduce sediment discharges from drain and irrigation of different land types (Mountain, Flatten, Reclaimed land). This study was carried out to analysis for the soil loss and sediment of drain and irrigation by comparing RUSLE method and amount of sediment from amount of dredging data of Korea Rural Corporation. The results of study were analyzed and summarized as follow. Size of soil sediment from the upper region of drain and irrigation of mountains bigger than lower region. But in case of flatten and reclaimed land, size of soil sediment from the upper and lower region of drain and irrigation did not classified. In case of comparison drain and irrigation without classifying of land type, size of soil sediment from irrigation is bigger than drain.

Design and Implementation of Integrated Query System for e-Business Registries (e-비즈니스 레지스트리 통합 질의 시스템 설계 및 구현)

  • 김계용;이규철
    • Journal of Information Technology Applications and Management
    • /
    • v.10 no.1
    • /
    • pp.127-146
    • /
    • 2003
  • With the spread of Internet, e-business using Internet technology is being actively developed and operated. Currently, on behalf of the international e-business framework, International standard such as ebXML and Web Service is being advanced. We are able to publish and search business information through ebXML and Web Service and then actual trading between partners is accomplished. By the way, it is Registry that play an important part in e-business. Registry is an e-business infrastructure for enabling building, deploying, and the discovery of business Information. We can do e-business through Registries dynamically and share the resources. Representatives of Registry are ebXML and UDDI used as an international standard. We will meet with some problems when using Registries. ebXML Is focused on B2B collaborations and Web Service Is focused on application integrations. So we must use ebXML and Web Service characteristically, and sometimes use all at need. ebXML and Web Service contain business information by Registry specific way. So When using the services offered by ebXML and Web Service, we should access each Registry by using Registry specific tools. This thesis intended to integrate business information from ebXML Registry and UDDI Registry to accomplish e-business conveniently This thesis defined the common data model as well as integrated query language for integrated access to ebXML and Web Service along with design and implementation of the system.

  • PDF

Correlation Analysis for deriving Control Parameters in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트 제어인자 도출을 위한 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong;Baek, Chang-In
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.895-900
    • /
    • 2008
  • It is the objective of the present study to conduct correlation analysis for deriving control parameters in vertical shafts using the results obtain by the design of experiments in the preceding research. The control parameters are categorized into objective parameters, derived parameters, condition parameters, operation parameters, and sensing parameters. The maximum pressure in the shaft should be sufficiently small in order to maintain exhaust hood performance. The pressure variations between floors should also be minimized in order to maintain uniform exhaust performance between floors and to save energy for excessive pressure drop in the shaft. The standard deviation based on -4Pa is proposed as an objective parameter to control pressure in shafts. The correlation equation has been obtained between the standard deviation and the sensing parameters of outdoor temperature and the pressure at the top of the shaft.

  • PDF

CALS System Development Methodology Using Document Trace Diagram and IDEF Model (Document Trace Diagram 과 IDEF 모델을 이용한 CALS 시스템 개발 방법론)

  • Kim, Soung-Hie;Cho, Sung-Sik;Lee, Jae-Kwang;Han, Chang-Hee;Yoon, Young-Suk
    • Asia pacific journal of information systems
    • /
    • v.8 no.3
    • /
    • pp.37-49
    • /
    • 1998
  • The basic goal of CALS is to improve transactions and relationships among organizations through information sharing and integration. CALS is an information strategy which needs strong cooperation between organizations or between users and developers in design step. However, current design methodologies using IDEF models, that are considered to be standard for CALS system development, has some limitations. For example, it is difficult for system developers to communicate with counterparts by IDEF model since IDEF models are difficult for counterparts to understand. In this paper, we suggest a development methodology for GALS systems by complementing IDEF model with Document Trace Diagram, which we developed as a communication tool, The concept of Document Trace Diagram stems from the fact that most information exchanged within or between organizations is in the form of documents and most standard operating procedures of organizations are about processing the documents. It helps system developers identify functions and their ICOMs (Input, Control, Output, Mechanism) with ease and little communication cost. With this methodology, we have constructed the GALS prototype system for construction industry.

  • PDF

Numerical study for performance analysis and design of a counterflow type cooling tower (대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구)

  • 이상윤;이정희;최영기;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells (복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석)

  • Cho, Jeong-Heum;Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

Studies on the Bioequivalence Test of Isoniazid Tablets (시판 이소니아짓 정제의 생물학적 동등성시험에 관한 연구)

  • Choi, Jun-Shik;An, Seon-Yeob
    • YAKHAK HOEJI
    • /
    • v.33 no.4
    • /
    • pp.229-236
    • /
    • 1989
  • Even though two different preparations are chemically equivalent, the variance of bioavailability differenciates the clinical effect of preparations, so that the preparations need to be evaluated by comparing bioavailability in vivo as well as chemical equivalence. In this study, bioequivalence tests of commercially available isoniazid tablets A, B, C and D (standard) were performed to give some guidelines to bioequivalence test. The bioavailability parameters obtained by drug administeration were statistically analyzed. Statistical evaluation of the data involved an analysis of variance for a cross over design. Cross over design was employed with 8 healthy volunteers. The results were within 20% difference of mean value in the AUC, Cmax, Tmax and amount of urinary excretion (Au) between standard and isoniazid tablets. The results of ANOVA showed no significant differences for 'group or sequence', but almost not for 'between subjects'. The tablet. A, B and D were within 20 min, but tablet C was within 50 min. Tablet A was biologically equivalent in the Au. tablet B biologically equivalent in the Au and AUC. Tablet C was biologically equivalent in the Au. The relationship between the dissolution rate and Au was significant.

  • PDF

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.