• Title/Summary/Keyword: Korea Design Standard

Search Result 3,774, Processing Time 0.032 seconds

Factors influencing the health-related quality of life of postmenopausal women with diabetes and osteoporosis: a secondary analysis of the Seventh Korea National Health and Nutrition Examination Survey (2016-2018) (골다공증이 있는 폐경 후 당뇨 여성의 건강관련 삶의 질 영향요인: 제7기 국민건강영양조사 자료(2016-2018년) 활용)

  • Kim, Hyuk Joon;Kim, Hye Young
    • Women's Health Nursing
    • /
    • v.28 no.2
    • /
    • pp.112-122
    • /
    • 2022
  • Purpose: The prevalence of osteoporosis in postmenopausal women is increasing, and diabetes patients have decreased bone density. Their health-related quality of life (HRQoL) is diminished by the resultant physical dysfunction and depression. The purpose of this study was to identify factors influencing HRQoL in postmenopausal women with diabetes and osteoporosis. Methods: This was a secondary data analysis of the Seventh Korea Health and Nutrition Examination Survey (2016-2018), which utilized a complex, multistage probability sample design. The participants in the study were 237 women with diabetes and osteoporosis. To evaluate the factors that influenced HRQoL, a complex-samples general linear model was constructed, and the Bonferroni correction was performed. Results: In this sample of women aged 45 to 80 years (mean±standard deviation, 71.12±7.21 years), the average HRQoL score was 0.83±0.18 out of 1.0. Factors influencing HRQoL were age (70s: t=-3.74, p<.001; 80s: t=-3.42, p=.001), walking for exercise more than 5 days a week (t=-2.83, p=.005), cerebrovascular disease (t=-8.33, p<.001), osteoarthritis (t=-2.04, p=.014), hypertension (t=2.03, p=.044), higher perceived stress (t=-2.17, p=.032), poor glycemic control (t=3.40, p=.001), waist circumference (t=-2.76, p=.007), sitting time per day (t=-2.10, p=.038), and a longer postmenopausal period (t=3.09, p=.002). Conclusion: In order to improve the HRQoL of postmenopausal women with osteoporosis and diabetes, it is necessary to implement intervention strategies that enable the effective management of chronic diseases, while preventing the complications of diabetes and minimizing stress through physical activity.

Digital Twin Model Design And Implementation Using UBS Process Data (UBS공정 데이터를 활용한 디지털트윈 모델 설계 및 구현)

  • Park, Seon-Hui;Bae, Jong-Hwan;Ko, Ho-Jeong
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.3
    • /
    • pp.63-68
    • /
    • 2022
  • Due to COVID-19, many paradigm shifts in existing manufacturing facilities and the expansion of non-face-to-face services are accelerating worldwide. A representative technology is digital twin technology. Such digital twin technology, which existed only conceptually in the past, has recently become feasible with the construction of a 5G-based network. Accordingly, this paper designed and implemented a part of the USB process to enable digital twins based on OPC UA communication, which is a standard interlocking structure, between real object objects and virtual reality-based USB process in accordance with this paradigm change. By reflecting the physical characteristics of real objects together, it is possible to simulate real-time synchronization of these with real objects. In the future, this can be applied to various industrial fields, and it is expected that it will be possible to reduce costs for decision-making and prevent dangerous accidents.

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details (특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가)

  • Kim, Seon Hoon;Lee, Deuck Hang;Kim, Yong Kyeom;Lee, Sang Won;Yeo, Un Yong;Park, Jung Eun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Implementation of temporal reasoning services using a domain-independent AI planner (영역-독립적인 인공지능 계획기를 이용한 시간 추론 서비스의 구현)

  • Kim, Hyun-Sik;Park, Chan-Young;Kim, In-Cheol
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.37-48
    • /
    • 2009
  • Household service robots should be able to provide their users with a variety of temporal reasoning services. In this paper, we propose an effective way of developing such temporal reasoning services using a domain-independent AI planner. Developing temporal reasoning services with a domain-independent AI planner, we have to address both the knowledge engineering problem of how to represent various real-world temporal constraints in a planning domain definition language, and the system design problem of how to realize the interface between the AI planner and the service consumer. In this paper, we introduce an example scenario and a set of typical temporal constraints for a household service robot, and then present how to represent them in the standard planning domain definition language. We also explain how to implement a service agent based on an AI planner in order to develop and provide new services efficiently.

Space planning about Personal Protective Equipment(PPE) Doffing Area to reduce cross-infection among healthcare workers (의료진 교차감염을 낮추기 위한 음압격리병동 내 개인보호구 탈의구역의 공간구성)

  • Park, Doeun;Lee, hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.37-44
    • /
    • 2023
  • Purpose: To decrease cross-infection, it's essential to analyze the spatial composition of the 'PPE doffing area'. Instead of solely relying on manpower standards, we should focus on responding to infectious diseases within the context of space planning. By doing so, we can lower the risk for healthcare workers' infection and ensure a level of safety in various environmental changes or new manpower input situations. Methods: This analysis is conducted specifically for facilities with negative pressure isolation wards. Additionally, interview surveys to obtain feedback from healthcare workers and incorporate their expertise into the design of the 'PPE doffing area' have been carried. Results: In a PPE doffing area, the standard spaces include a PPE doffing room, a shower room, and a clothing room. Depending on the facility environment or the level of infectious diseases, a Decontamination room or Anteroom can be optionally added. Healthcare workers who remove their PPE in the PPE doffing room should avoid re-entering the Negative pressure room. The shower room is often underutilized. When planning for a future PPE doffing area, an aisle space or passageway must be included even if a shower room is planned. Implications: This study examined the space used by healthcare workers rather than patients, with a focus on infection prevention through architectural planning rather than individual efforts. However, the investigation was limited to facilities that have been converted from general wards to negative pressure isolation wards, so it cannot be generalized to all infectious disease facilities.

Automated Finite Element Mesh Generation for Integrated Structural Systems (통합 구조 시스템의 유한요소망 형성의 자동화)

  • Yoon, Chongyul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.77-82
    • /
    • 2023
  • The structural analysis module is an essential part of any integrated structural system. Diverse integrated systems today require, from the analysis module, efficient real-time responses to real-time input such as earthquake signals, extreme weather-related forces, and man-made accidents. An integrated system may also be for the entire life span of a civil structure conceived during the initial conception, developed throughout various design stages, effectively used in construction, and utilized during usage and maintenance. All these integrated systems' essential part is the structural analysis module, which must be automated and computationally efficient so that responses may be almost immediate. The finite element method is often used for structural analysis, and for automation, many effective finite element meshes must be automatically generated for a given analysis. A computationally efficient finite element mesh generation scheme based on the r-h method of mesh refinement using strain deviations from the values at the Gauss points as error estimates from the previous mesh is described. Shape factors are used to sort out overly distorted elements. A standard cantilever beam analyzed by four-node plane stress elements is used as an example to show the effectiveness of the automated algorithm for a time-domain dynamic analysis. Although recent developments in computer hardware and software have made many new applications in integrated structural systems possible, structural analysis still needs to be executed efficiently in real-time. The algorithm applies to diverse integrated systems, including nonlinear analyses and general dynamic problems in earthquake engineering.

Proposal of Hydrologic Performance Evaluation Method for the Improvement of Rainwater Management and Utilization of G-SEED (녹색건축 인증제도의 빗물관리 및 이용 항목의 개선을 위한 수문학적 성능평가 방법 제안)

  • Park, Jin;Han, Mooyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.158-158
    • /
    • 2021
  • 도시에 불투수면적이 증가하고, 기후변화가 극심해져감에 따라 홍수 및 열섬현상과 같은 도시의 물 문제가 발생하고 있다. 이를 해결하기 위한 정책의 일환으로 우리나라의 녹색건축인증제도(Green Standard for Energy and Environmental Design, G-SEED)에서는 물순환 관리를 평가하고 있다. 하지만, 현재 G-SEED의 평가방법을 살펴보면 빗물관리시설의 설치 정도로 평가하고 있고, 강우 특성 또한 고려되고 있지 않다. 그러므로 본 연구에서는 G-SEED의 빗물관리 및 이용 항목에 대해 수문 모델을 통해 효과를 정량화함으로써 성능에 따라 평가할 수 있는 방법을 제안하였다. 빗물관리 항목에서는 유출저감률을, 빗물이용 항목에서는 빗물이용률을 평가지표로 선정하였고, 각 평가인자를 산출하기 위하여 개념모델을 적용하였다. 빗물이용시설의 경우 초기우수배제장치 용량과 필터 효율에 따른 빗물유입량의 변화와 급수인원에 따른 수요량 변화를 고려한 수문모델을 개발하였고, 수요량과 빗물저장조 용량에 따른 유출저감률과 빗물이용률을 알아보기 위해 MATLAB을 이용하여 모의해보았다. 또한, 옥상녹화의 경우에는 강우, 저류, 증발산, 유출을 고려한 수문흐름모델을 적용하였고, 토층의 두께와 배수(저장) 층의 용량에 따라 모의하여 평가기준을 선정하였다. 제안된 수문모델의 검증을 위하여 서울대학교 기숙사와 35동 옥상녹화의 실측데이터를 비교하였고, 적용성 평가를 위해 RMSE(Root Mean Square Error)와 NSE(Nash-Sutcliffe Efficiency)를 이용하였다. 본 연구에서 제안된 방법을 통해 빗물관리시설의 수문학적 성능에 따른 평가가 가능해질 것이며 설계자와 건축가들로 하여금 실질적인 효과를 내는 시설을 설치하게끔 유도할 수 있을 것이다.

  • PDF

Determination of Thermal Cracking Index of Internal Restricted Mass Concrete Using a Numerical Analysis (수치분석을 통한 내부구속 매스콘크리트의 온도균열지수 결정)

  • Seo, Ki-Young;Kim, Hee-Sung;Jin, Chi-Sub
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.57-67
    • /
    • 2007
  • The service life of concrete structure is to a great extent influenced by crack developed at early ages of concrete material. Especially, hydration heat is a main cause of thermal cracking at mass concrete structures. The thermal cracking of massive structure is analyzed of the thermal cracking index which was presented Concrete Standard Specifications. The thesis analyzed the thermal cracking index which considered various variable (cement type, height of casting, curing condition, concrete mixing temperature, the unit cement content) at internal restricted mass concrete. The analysis result is denoted increase and decrease rate of thermal cracking index whenever the variables change. The results is helped to understand thermal cracking every time structures is designed and constructed. And I think that it is useful economic and stable design of mass concrete structures.

A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis (통계분석에 의한 현장 타설 콘크리트의 품질 특성에 관한 연구)

  • Ji, Suk-Won;Jung, Si-Jin;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.171-180
    • /
    • 2007
  • The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.