• Title/Summary/Keyword: Korea Design Standard

Search Result 3,774, Processing Time 0.033 seconds

Indictor Library for RF Integrated Circuits in Standard Digital 0.18 μm CMOS Technology (RF 집적회로를 위한 0.18 μm CMOS 표준 디지털 공정 기반 인덕터 라이브러리)

  • Jung, Wee-Shin;Kim, Seung-Soo;Park, Yong-Guk;Won, Kwang-Ho;Shin, Hyun-Chol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.530-538
    • /
    • 2007
  • An inductor library for efficient low cost RFIC design has been developed based on a standard digital 0.18 ${\mu}m$ CMOS process. The developed library provides four structural variations that are most popular in RFIC design; standard spiral structure, patterned ground shield(PGS) structure to enhance quality factor, stacked structure to enable high inductance values in a given silicon area, multilayer structure to lower series resistance. Electromagnetic simulation, equivalent circuit, and parameter extraction processes have been verified based on measurement results. The extensive measurement and simulation results of the inductor library can be a great asset for low cost RFIC design and development.

Thermal Margin Analysis of the Korea Nuclear Unit 1 Reactor Core Consisting of Standard or Optimized Fuel Assemblies (표준 핵연료집합체 또는 최적 핵연료집합체가 장전된 원자력 1호기 원자로심의 열적여유도 분석)

  • Hyun Koon Kim;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.155-160
    • /
    • 1984
  • Analyzed is the thermal margin of the Korea Nuclear Unit 1 (KNU-1) reactor core consisting of either 14 x 14 standard fuel assemblies (SFA) or optimized fuel assemblies (OFA). Employed for the analysis are two different thermal design methods; traditional and statistical thermal design method. Compared to the traditional design thermal method, the statistical thermal design method improves the core thermal margin utilizing best-estimate values for the core operating parameters combining their uncertainties in a statistical manner. Calculations are performed using a steady state and transient thermal-hydraulic analysis computer program, COBRA-IV-i. Calculated results show that the statistical thermal design method significantly improves the thermal margin and satisfies the core thermal design base of the KNU-1 SFA and OFA core. However, the thermal design base can not be met, if the traditional thermal design method is employed for the OFA role analysis.

  • PDF

A Study on the Evaluation of Member Buckling Performance of Space Frame Structures (스페이스 프레임 구조물의 부재좌굴성능 평가방안 연구)

  • Kang, Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.176-182
    • /
    • 2018
  • The purpose of this study was to investigate the safety and rationality of buckling strength and length coefficient by comparing with the design standards of domestic and foreign compression materials based on the buckling test results of circular steel pipe with ball joints. The types of round steel pipes selected for buckling performance evaluation were ø$48.6{\times}2.8t$, ø$60.5{\times}3.2t$ and ø$76.3{\times}3.2t$. For the design of domestic and foreign compression materials, Korea 's Load Resistance and Factor Design, Japan' s Limit State Design, and British Standard BS5950 standard were applied. In this study, we compared and analyzed the buckling performance between the experimental results of the previous research and the domestic and foreign design standards. The results were summarized as follows. As a result of applying the full length of the member to the buckling length in the compression materials design standards of each country, it was 64-89% of the buckling strength by the experiment. Therefore, it is deemed desirable to perform the member design according to the current design standard formula for safety. Experimental results show that the measured buckling strength was 1.02-1.43 times higher than the buckling strength of pure cylindrical steel tubes in the design standards of Korea, Japan and the United Kingdom compression materials. Consequently, it seemed that the buckling strength of individual member in the design of space frame structure should be considered buckling coefficient as the length of pure round steel pipe rather than the length of inter-node.

Study on development of three generation family type apartment plan -Deduction of standard plan and compare standard plan with three generation family type apartment- (3대 가족형 집합주거의 실용화를 위한 기초연구(I) -계획기준의 도출과 계획기준을 이용한 3대 가족형 주거와의 비교분석을 중심으로-)

  • Yun, Sam-Seok;Kim, Jin-Mo
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.39-46
    • /
    • 2007
  • The aim of this study was to recognize the need of three generation family house that is traditional house type of Korea. First, the pre-research analysis method was used for this study. And then, there are three type's grouping like those are as follows; 1) Recognition of three generation family house. 2) Type of three generation family house. 3) Plans of three generation family house. The analysis results are as follows; If the conditions are better than now, recognition is positive. Type are living together and next doors type can direct access. Some standart plan is been about room's number, house's area, bath's number and so on. Second, try to compare plan - this plan already has been used building - with standard plan. The compare result are as follows; three generation family houses - be used by whom - do not apply to standard plan. Almost houses have a three room that is less than the standard plan. All houses have a number of two bath that is less than the standard plan too. Condition of consideration is suitable to ages in next door type, but in case of living together type that consider user whom is use the inner room. Separation of entrance distinguish between the living together type and the next doors type. In case of living together type Dining with Kitchen room's number is one, but the next doors type have the number of two.

Mechanical Properties of the Oriented Strand Board (OSB) Distributed in the Korean Market

  • Eun-Chang KANG;Min LEE;Sang-Min LEE;Se-Hwi PARK
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.253-269
    • /
    • 2023
  • Oriented strand board (OSB) distributed in Korea was collected, and its mechanical properties were investigated according to the International Organization for Standardization (ISO), Japanese Industrial Standards, and Korean Design Standard. Ten types of OSBs were collected, including six types for walls and others for floors. The thickness swelling, moisture content, and density of each product satisfied the ISO standards. All products showed lower formaldehyde emission values than those of the SE0 grade. The internal bonding strengths of all products, except products B, H, and I, met the ISO standards. However, products A, B, C, F, and H did not satisfy the thickness swelling standard of the load-bearing OSB for use in dry conditions. Products D and G showed heavy duty load-bearing OSB for use in humid conditions in terms of internal bonding and bending strength after boiling. In the nail head pull-through force and lateral nail resistance tests, all products met the standards. In terms of the structural bending performance (four points), the six types of OSBs for walls satisfied the standard for bending strength and modulus of elasticity. All the products for flooring met the standard for bending strength but, except for product G, the products did not meet the standard for modulus of elasticity. Although the results of this study cannot represent the performance of all imported OSBs, considering the above results, the water resistance performance of seven types of OSB products did not meet the standard, and 10 types of products did not match the labeling grades.

Quality Management (QM) Standard Issues in FM - Based on Guidance on quality in European FM Standard

  • Lee, So Young;Jang, Yon Hwa;Lee, Myoung Sik
    • Architectural research
    • /
    • v.18 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • Importance of FM has rapidly increased because of its growing business. However, due to lack of clarity and identity of FM in professional areas, standardization of FM became to be imperative in such a rapidly changing global business environment. Facility services are defined as the provision of support the primary activities of an organization, delivered by an internal or external provider. Majority of FM activities are services related to 'space and infrastructure' and 'people and organization' (CEN, 2011). The purpose of this study is to investigate definitions and characteristics of FM from both globally and domestic environment, by comparison with international or national standards, to identify quality management in FM and service characteristics of FM, to investigate the differences in service level elaboration in FM, and to suggest standard issues of quality management in FM service quality. This study examines contents of the European Standards in FM, Part 3 'Guidance on quality in Facility Management, especially for the process of QM standardized by CEN (2011) and explores undefined issues such as service level, measurement metrics according to service characteristics of FM. The European FM Standard guides the common process of QM in terms of requirements specification, service level elaboration, measurement metrics development although it does not specifically address various service levels, specific performance metrics and indicators.

A Study on Domestic Standard Parameter Setting for BIM-based Energy Performance Evaluation - Focused on Possession Area per Person of Occupants in Government Offices - (BIM 기반 에너지성능평가를 위한 국내 표준 매개변수 설정 방안에 대한 연구 - 공공청사 업무시설의 재실자 1인당 점유면적을 중심으로 -)

  • Lee, Yun-Jeong;Lee, Kweon-Hyoung;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-21
    • /
    • 2015
  • Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.

Standardization of Infrastructure Information Modeling based on BIM Information Framework (BIM 정보프레임워크 기반의 토목구조물 정보모델링 표준화방안)

  • Nam, Jeong-Yong;Jo, Chan Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.3
    • /
    • pp.281-293
    • /
    • 2014
  • Although there have been a lot of BIM R&Ds in the civil engineering and their applications to the real projects, BIM in the field is still known to be behind the other areas. One of the reasons for this should be that the civil projects is generally too public for private participants to try new technologies, but it is mainly because the projects are so huge and complex that we still have the working environment where the systematic information sharing or exchanging is not smooth enough. In this paper, we are verifying the possibility and proposing the direction of BIM information standardization technology in civil engineering based on the integrated BIM information standard framework. For this purpose, after reviewing the introduction plan for BIM information framework, we applied it to an actual civil structure for test. The implementation result proved that the framework has possibility and effectiveness for the takeoff and construction cost calculation, which confirmed the standard framework needs to be extended consistently. This study is expected to contribute to the standard system establishment and its technology propagation for BIM development in the civil engineering.

Circuit design of an RSFQ counter for voltage standard applications (전압 표준용 RSFQ counter회로의 설계)

  • 남두우;김규태;김진영;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.127-130
    • /
    • 2003
  • An RSFQ (Rapid Single Flux Quantum) counter can be used as a frequency divider that was an essential part of a programmable voltage standard chip. The voltage standard chip is composed of two circuit parts, a counter and an antenna Analog signal of tens to hundreds ㎓ may be applied to a finline antenna part. This analog signal can be converted to the stream of SFQ voltage pulses by a DC/SFQ circuit. The number of voltage pulses can be reduced by 2n times when they pass through a counter that is composed of n T Flip-Flops (Toggle Flip-Flop). Such a counter can be used not only as a frequency divider, but also to build a programmable voltage standard chip. So, its application range can be telecommunication, high speed RAM, microprocessor, etc. In this work, we have used Xic, WRspice, and L-meter to design an RSFQ counter. After circuit optimization, we could obtain the bias current margins of the T Flip-Flop circuit to be above 31% Our RSFQ counter circuit designs were based on the 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology.

  • PDF

Design and Implementation of the ebXML Standard Conformance and Interoperability Testing Tools (ebXML 표준 적합성 및 상호운용성 테스트 도구의 설계 및 구현)

  • Lim, Cheol-Su;Park, Byeong-Sub;Choi, Hyun-Sub
    • The KIPS Transactions:PartD
    • /
    • v.11D no.6
    • /
    • pp.1341-1348
    • /
    • 2004
  • As of an international standard in e-business domains, ebXML solutions are required to be tested and authenticated whether they can satisfy the conformance and interoperability requirements. In this paper, we design and implement the ebXML conformance and interoperability testing tools that observe the standard specification in conformity with ebXML Message Service v2.0, ebXML Registry Service v2.0 and ebXML CPP/A Y2.0. With this regard, our research would serve in building the verification and authentication service infrastructure for fitting standard ebXML e-business solutions with ebXML conformance and interoperability testing tools.