• Title/Summary/Keyword: Knife

Search Result 658, Processing Time 0.024 seconds

Diagnosis of Coating Deviation in Continuous Galvanizing Line (연속용융아연 도금라인의 도금편차 진단)

  • 배용환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.192-199
    • /
    • 2002
  • In continuous galvanizing process, the mass of zinc deposited and its distribution are controlled by the air pressure, effective distance from the air knife nozzle to the steel strip surface and line speed. Coating defects are resulted from the unbalance of these control factors and the inaccuracy of coating equipments. This paper investigates the main cause of coating deviation and a new air knife system for control of coating thickness was developed. We investigate dynamic pressure variation by air knife types. It is found that the coating deviation is caused by the unbalance of dynamic pressure, the irregularity of strip position, and the strip vibration. Formulating a useful coating model by using present working condition, an optimal working condition is suggested. The productivity and coating quality are improved by applying the result of this research at the shop floor.

Jamming Effects of GPS L1 C/A Signal by Knife-Edge Diffraction Loss at Seoul Metropolitan Northwestern Region (회절을 고려한 수도권 서북부 지역에서 GPS L1 C/A 신호의 재밍영향분석)

  • Yoo, Seungsoo;Kim, Sun Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.757-763
    • /
    • 2013
  • This study discusses the multiple knife-edge diffraction loss with the receiver and jammer located in the Seoul metropolitan northwestern region. The considered positioning and jamming signals are the GPS L1 C/A signal and several jamming signals such as the wideband Gaussian noise, matched spectrum, and continuous wave signals. To calculate the accurate diffraction effects, the 3-dimensional topography data at the Seoul metropolitan northwestern region was used.

A STUDY ON THE FLOW CHARACTERISTICS OF AIR-KNIFE USING A CONSTANT EXPANSION RATE NOZZLE (팽창률이 일정한 노즐을 사용한 AIR-KNIFE 유동에 관한 연구)

  • Lee, Dong-Won;Kang, Nam-Cheol;Kim, Guen-Young;Kwon, Young-Doo;Kwon, Soon-Bum
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the process of continuous hot-dip galvanizing, it is well known that the gas wiping through an air knife system is most effective because of its uniformity in coating thickness, possibility of thin coating, workability in high speed, and simplicity of control. However, gas wiping used in the galvanizing process brings about a problem of splashing at the strip edge above a certain high speed of process. It is also known that the problem of edge splashing is more harmful than that at the mid strip surface. For a given liquid(of a certain viscosity and surface tension), the onset of splashing mainly depends upon the strip velocity, the gas-jet pressure, and the nozzle's stand-off distance. In these connections in the present study, we proposed three kinds of air knife system having nozzles of constant expansion rate, and compared the jet structures issuing from newly proposed nozzle systems with the result by a conventional one. In numerical analysis, the governing equations are consisted of two-dimensional time dependent Navier-Stokes equations, and the standard k-${\varepsilon}$ turbulence model is employed to solve turbulence stress and so on. As the result, it is found that we had better use the constant expansion-rate nozzle which can be interpreted from the point view of the energy saving for the same coating thickness. Also, we better reduce the size of separation bubble and enhance the cutting ability at the strip surface, by using an air-knife having constant expansion-rate nozzle.

Hydrodynamic Evaluation for Developing the New Inflatable Kayak (신형 인플래터블 카약 개발을 위한 유체역학적 성능평가)

  • Hah, Chong-Ku;Kim, Ho;Lim, Lee-Young;Ki, Jae-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.334-341
    • /
    • 2015
  • This study is to evaluate hydrodynamic performance evaluation between three kinds of inflatable kayaks, that is, a frame kayak, a needle knife kayak, and a v-hull kayak. In order to test, inclining and turning trial test are performed in the Ocean Engineering Basin. Also, a resistance test is performed with a reduced scale kayak in the circulating water channel. Consequently, First, the moment arm of a v-hull kayak is the largest with 132.4mm, but turning radius of one was the smallest of them. Second, the resistance of a needle knife kayak is the smallest with 71N, the center of gravity of one was the lowest with 0.128m of them, and then needle knife kayak occurs in a draft overall. Consequently, the v-hull kayak has had the advantages on restoring force and turning performance than others. The needle knife kayak has been more excellent on resistance and center of gravity than others.

Stereotactic Radiosurgery with the CyberKnife for Pituitary Adenomas

  • Cho, Chul-Bum;Park, Hae-Kwan;Joo, Won-Il;Chough, Chung-Kee;Lee, Kyung-Jin;Rha, Hyoung-Kyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.157-163
    • /
    • 2009
  • Objective : In recent years, CyberKnife has emerged as an important treatment modality in the management of pituitary adenomas. Treatment results after performing CyberKnife and the complications of this procedure are reviewed. Methods : Twenty-six patients with pituitary adenomas received stereotactic radiosurgery with the CyberKnife (CKRS). The follow-up periods ranged from 7 months to 47 months (mean$\pm$SD : $30{\pm}12.7$ months). The patients consisted of 17 with non-functioning adenomas, 3 with prolactinomas and 6 with acromegaly. The change in the tumor volume, visual acuity, hormonal function, and complications by this therapy were analyzed in each case. Results : The tumor control rate was 92.3%. Hormonal function was improved in all of the 9 (100%) functioning adenomas. Hormonal normalization was observed in 4 of the 9 (44%) patients with a mean duration of 16 months. In two patients (7.6%), visual acuity worsened due to cystic enlargement of the tumor after CKRS. No other complications were observed. Conclusion : CyberKnife is considered safe and effective in selected patients with pituitary adenomas. However, longer follow-up is required for a more complete assessment of late toxicity and treatment efficacy.

The cutting process improvement for cut kimchi cabbage quality (절단배추의 선도유지를 위한 절단 공정 개선)

  • Seong, Gi-Un;Chung, Hun-Sik;Chung, Shin-Kyo
    • Food Science and Preservation
    • /
    • v.22 no.1
    • /
    • pp.154-157
    • /
    • 2015
  • To maintain the freshness and to prevent browning of cut Kimchi cabbages, the effect of the cutting process using a ceramic knife under $N_2$ blowing on the quality of the cut Kimchi cabbages was investigated. Kimchi cabbages cut with a ceramic knife under $N_2$ gas blowing conditions (NC) were stored at $5^{\circ}C$ for 7 days, and their weight reduction ratio and the browning degree and appearance were compared with those of the control treatment samples (OS; cut with a stainless steel knife under normal air, OC; cut with a ceramic knife under normal air). The weight reduction ratios were 0.07~0.13%, and the NC treatment showed the lowest reduction ratio among all the treatments (p<0.05). The Hunter L values increased, but the a and b values decreased after 5-day storage in all the treatments. The NC treatment had higher L values but lower a and b values than the OS and OC treatments. The browning degrees by Hunter color value, PPO activity, and appearances were the least in the NC treatment (p<0.05). The cutting process with a ceramic knife under $N_2$ blowing could be applied to the cutting of vegetable products and for minimal fruit processing.

The Usefulness of Sector Blocks in Gamma Knife Surgery with Trigeminal Neuralgia (삼차신경통 환자의 감마나이프 수술 시 섹터블록 사용의 유용성 평가)

  • Jung, Chang-Young;Back, Geum-Mun;Woo, Sung-Ho;Kim, Myoung-Jun;Hwang, Jung-Ho;Lee, Hyun-Bi;Kim, Ho-Sung
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.337-341
    • /
    • 2018
  • Sector block is not used for Gamma Knife surgery in patients with generalized trigeminal neuralgia but sector block is used to reduce the dose reaching the brain stem when the trigeminal ganglgia and the 'Brain stem', radiation sensitive tissue, are adjacent. In the Gamma Knife surgical plan of this study, a surgical plan was established using a Leksell Gamma Plan 11. 1.0 (Elekta Instrument AB, Sweden) with one patient (Block unused, Brain stem dose No volume over 12 Gy, Case 1) who did not need a sector block and four patients (Block unused, Brain stem dose 12 Gy or more, Case 2~5) with a sector block. Magnetic resonance images were obtained by MPRAGE T1 and CISS Respectively. When the trigeminal ganglion is in close proximity to the brain stem, the brain stem volume is decreased when the sector block is used, while the treatment time was increased. In conclusion, This Study evaluates the usefulness of the Sector block in brain stem through Gamma Knife surgery in trigeminal neuralgia, which is considered to be the most important factor for the Gamma Knife surgery.

A Study on the applicability of ultrasonic knife for processing CFRTP materials (CFRTP 소재 가공을 위한 초음파 나이프 적용 가능성에 관한 연구)

  • Ki-Hyeok Song;Hye-Jin Kim;Ji-young Park;Si-Myung Sung
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.9-14
    • /
    • 2023
  • In this study, an experiment was conducted to confirm the applicability of the external shape control of the ultrasonic knife to the CFRTP material, which is the base material of thermoplastic. TC910 based on polyamide6 (PA6) was used as the material. The slope 와 and tool transfer speed of the material and tool were selected as process factors for processing, and the following results were obtained. Under all cutting conditions using an ultrasonic knife, friction heat caused by high-frequency vibration was issued at 150℃ at the contact part between the material and the knife during cutting. As a result of the cutting force analysis, the faster the transfer speed, the higher the cutting force as the angle of entry of the blade increased, and the size of the cutting force changed during cutting. As for the size of the burr in accordance with the transfer speed condition, the smallest burr occurred at 150mm/min in the side part, and the smallest burr occurred at 150mm/min and 200mm/min in the case of the outlet burr. The size of the burr according to the entry angle tended to decrease as the tool entry angle increased, and the side part tended to increase as the tool entry angle increased. As a result of the cutting surface analysis, it was confirmed that the base material was eluted under all conditions, and the faster the transfer speed, the lower the elution phenomenon of the base material. Based on the above results, cutting the CFRTP material with an ultrasonic knife is possible, but the effect on heat generation caused by friction needs to be minimized, and further research needs to be conducted on this.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Repeat Stereotactic Radiosurgery for Recurred Metastatic Brain Tumors

  • Kim, In-Young;Jung, Shin;Jung, Tae-Young;Moon, Kyung-Sub;Jang, Woo-Youl;Park, Jae-Young;Song, Tae-Wook;Lim, Sa-Hoe
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.633-639
    • /
    • 2018
  • Objective : We investigated the outcomes of repeat stereotactic radiosurgery (SRS) for metastatic brain tumors that locally recurred despite previous SRS, focusing on the tumor control. Methods : A total of 114 patients with 176 locally recurring metastatic brain tumors underwent repeat SRS after previous SRS. The mean age was 59.4 years (range, 33 to 85), and there were 68 male and 46 female patients. The primary cancer types were non-small cell lung cancer (n=67), small cell lung cancer (n=12), gastrointestinal tract cancer (n=15), breast cancer (n=10), and others (n=10). The number of patients with a single recurring metastasis was 95 (79.8%), and another 19 had multiple recurrences. At the time of the repeat SRS, the mean volume of the locally recurring tumors was 5.94 mL (range, 0.42 to 29.94). We prescribed a mean margin dose of 17.04 Gy (range, 12 to 24) to the isodose line at the tumor border primarily using a 50% isodose line. Results : After the repeat SRS, we obtained clinical and magnetic resonance imaging follow-up data for 84 patients (73.7%) with a total of 108 tumors. The tumor control rate was 53.5% (58 of the 108), and the median and mean progression-free survival (PFS) periods were 246 and 383 days, respectively. The prognostic factors that were significantly related to better tumor control were prescription radiation dose of 16 Gy (p=0.000) and tumor volume less than both 4 mL (p=0.001) and 10 mL at the repeat SRS (p=0.008). The overall survival (OS) periods for all 114 patients after repeat SRS varied from 1 to 56 months, and median and mean OS periods were 229 and 404 days after the repeat SRS, respectively. The main cause of death was systemic problems including pulmonary dysfunction (n=58, 51%), and the identified direct or suspected brain-related death rate was around 20%. Conclusion : The tumor control following repeat SRS for locally recurring metastatic brain tumors after a previous SRS is relatively lower than that for primary SRS. However, both low tumor volume and high prescription radiation dose were significantly related to the tumor control following repeat SRS for these tumors after previous SRS, which is a general understanding of primary SRS for metastatic brain tumors.