• 제목/요약/키워드: Knee joint injury

검색결과 172건 처리시간 0.026초

Comparison of difference in muscle activity ratio, ground reaction force and knee valgus angle during single leg squat and landing according to dynamic taping

  • Ha, Tae-Won;Park, Sam-Ho;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.281-286
    • /
    • 2020
  • Objective: This study examined the effects of dynamic tape applied to the patellofemoral joint on the knee valgus angle, muscle activity, and ground reaction force during a single leg squat (SLS) and single leg landing (SLL). Design: Cross-sectional study. Methods: Twenty-four subjects (11 male, 13 female) who met the inclusion criteria were screened by the knee palpation and patella compression tests. First, the knee valgus angle and muscle activity during SLS were measured. Second, the knee valgus angle and ground reaction force during SLL were measured. For the intervention, a patella joint loop using dynamic tape was used. The knee valgus angle, muscle activities in SLS and SLL after the intervention, and the ground reaction force were measured in the same way. A paired t-test was used to examine the difference between before and after the intervention. Results: The knee valgus angle showed a statistically significant improvement after dynamic taping application in SLS and SLL (p<0.05). The differences in muscle activity of the VL/VMO and ground reaction forces were not statistically significant after dynamic taping application in SLS and SLL. Conclusions: This study showed that dynamic taping applied around the patellofemoral joint was effective in improving the knee valgus angle in SLS and SLL and had a reduced risk of secondary injury during sports activity.

척수마비환자 재활훈련용 보행보조기의 인체진동을 고려한 무릎관절 시스템 진동제어(II) (Vibration Control of a Knee Joint System considering Human Vibration of the New R.G.O. for a Rehabilitation Trainning of Paraplegia (II))

  • 김명회;장대진;백윤수;박영필;박창일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.446-452
    • /
    • 2002
  • This paper Presents a 3-D design and a Vibration control of a new walking R.G.O.(Robotic Gait Orthosis) and would like to develop a simulation by this walking system. The vibration control and evaluation of the new knee joint mechanism on the biped walking R.G.O.(Robotic Gait Orthosis) was a very unique system and was to obtain by the 3-axis accelerometer with a low frequency vibration for the paraplegia It will be expect that the spinal cord injury patients are able to recover effectively by a biped walking R.G.O.. The new knee joint system of both legs were adopted with a good kinematic characteristics. It was designed attached a DC-srevo motor and controller, with a human wear type. It was able to accomodate itself to a environments of S.C.I. Patients. It will be expect that the spinal cord injury patients are able to recover effectively by a new walking R.G.O. system.

  • PDF

외발 착지 시 신체적 특성 요인들이 발목 관절 상해에 미치는 영향 (Effects of Physical Characteristics Factors on Ankle Joint Injury during One Leg Drop Landing)

  • 이성열;이효근;권문석
    • 한국응용과학기술학회지
    • /
    • 제37권4호
    • /
    • pp.839-847
    • /
    • 2020
  • 본 연구는 외발 착지 시 신체적 특성 요인들인 발목 유연성, 성별, Q-angle이 발목 관절 상해 요인들에 미치는 영향을 분석하는데 목적이 있었다. 이를 위해 오른발을 주발로 사용하고 체육을 전공하는 20대 남성 16명(나이: 20.19±1.78 years, 체중: 69.54±10.12 kg, 신장: 173.22±4.43 cm), 여성 16명(나이: 21.05±1.53 years, 체중: 61.75±6.97 kg, 신장: 159.34±4.56 cm)을 연구대상자로 선정하였다. 외발 착지 시 신체적 특성 요인들이 발목 관절 상해에 미치는 영향을 확인하기 위하여 첫째, 발목 상해 경험에 따른 하지 관절 움직임과 관절 모멘트의 독립 t-test를 실시하였다(α = .05). 둘째, t-test를 통하여 유의한 차이를 나타낸 변인을 종속변인으로 설정하고 발목 유연성, 성별의 차이, Q-angle을 독립변인으로 지정하여 선형다중회귀분석(Multiple Linear Regression)을 사용하였다(α = .05). 본 연구결과 발목 관절 상해를 경험한 그룹은 상해를 경험하지 않은 그룹과는 다르게 발목 관절의 내전, 무릎 관절의 내측 회전을 통한 착지 전략과 기술을 사용하는 것으로 나타났다. 또한 이러한 움직임은 발목 관절의 신전 모멘트를 증가시키고, 엉덩 관절의 신전 모멘트는 감소시키는 것으로 확인되었다. 특히 발목의 배측굴곡 유연성은 발목과 무릎의 착지전략에 영향을 미치며, 성별의 차이는 발목의 신전 모멘트에 영향을 미치는 것을 알 수 있었다. 따라서 외발 착지 시 신체적 특성 요인들이 발목 관절 상해에 영향을 미치는 요인들임을 확인 할 수 있었다.

초음파를 이용한 슬관절 내측 불안정 평가 -측정기법- (Evaluation of Medial Instability of the Knee with Ultrasonography - Technical note -)

  • 김정만;이동엽;고인준;김승민
    • 대한정형외과 초음파학회지
    • /
    • 제1권2호
    • /
    • pp.73-77
    • /
    • 2008
  • 목적: 슬관절의 내측 측부 인대 손상으로 인한 내측 불안정의 정도 측정 시에 초음파를 이용하여 내반 및 외반 상태에서 동적으로 측정하는 기법을 기술하고자 한다. 대상 및 방법: 2008년 1월부터 2008년 4월까지 내측 측부 인대의 손상이 있었던 7예를 대상으로 하였다. 추시 관찰 시에 손상 직후 운동제한 보조기(limited motion brace)를 착용시켜 보존적 치료를 시행하였고 수상 직후, 6주 및 12주에 초음파로 내측 불안정성의 치유 경과를 관찰하였다. 평가는 슬관절을 30도 굴곡시키고 내반 및 외반 상태에서 대퇴골의 내측f 상과의 직하부에서 경골의 골 기시부까지의 거리를 계측하였다. 결과: 초음파 이용 시 내측 상과(medial epicondyle) 직하부에 골피(cortex)가 직선으로 내려가기 시작하는 부위와 경골 근위부의 관절 연골 둥근 부분 직하부의 골피 시작 부위 사이의 거리를 계측하였고 내반 및 외반은 하지 중력 만을 이용한 생리적 상태로 초음파 시야를 조정하면서 동적으로 측정하여 항상성 있는 결과를 얻을 수 있었다. 결론: 초음파는 내측 불안정의 정도 평가 시에 내측 측부 인대의 추가 손상 없이 내반 및 외반의 동적 상태로 측정할 수 있는 방법이다.

  • PDF

달리기 운동을 하는 사람에서 무릎 손상의 예방과 재활 (Prevention and Rehabilitation of Runner's Knee Injury)

  • 서승석;김정한
    • 대한정형외과스포츠의학회지
    • /
    • 제9권1호
    • /
    • pp.22-27
    • /
    • 2010
  • 도시화, 사회 경제적 발달로 인하여 많은 사람들이 달리기 운동을 즐기고 있다. 달리기는 단순한 운동이지만 반복적인 동작을 하기 때문에 관절에 특이적인 손상이 발생될 수가 있다. 달리기 운동 손상의 원인은 급성기의 손상보다는 만성적인 과사용 증후군으로 인한 것이 대부분이다. 또한 달리기를 할 때 흔히 동반되는 손상은 전방 슬관절 통증, 장경 인대 증후군, 피로 골절, 족저 근막염, 아킬레스 건염, 후방 경골 인대 증후군 등이 있다. 달리기 운동 손상의 가장 흔한 부위는 무릎 관절이다. 이에 저자들은 문헌 고찰을 하여, 달리기 운동 손상 중에서 무릎에서 발생하는 손상의 종류, 원인, 예방, 재활적인 치료 등을 중심으로 알아보고자 한다.

  • PDF

축구화 스터드 형태에 따른 무릎 모멘트의 변화 (Changes in Knee Joint Loading on Infilled Turf with Different Soccer Cleat Designs)

  • 박상균;이중숙;박승범
    • 한국운동역학회지
    • /
    • 제19권2호
    • /
    • pp.369-377
    • /
    • 2009
  • The purpose of this study was to determine the relationship between different soccer cleat designs and knee joint moments. Twelve physically active males (mean(SD): age: 26.4(6.2)yrs; height: 176.4(4.1)cm; mass: 74.0 (7.4)kg) were recruited Kinematic and force plate data were collected for all subjects during normal running and a $45^{\circ}$ cutting maneuver, called a v-cut. Both motions were performed at $4.0{\pm}0.2\;m/s$ on infilled artificial turf with three pairs of soccer cleats of different sole plate designs, and one pair of neutral running shoes. Inverse dynamics were used to calculate three dimensional knee joint moments, with repeated measures ANOVA and post hoc paired Student's t-test used to determine significance between shoe conditions. Significant differences were found in the extension moments of the knee for running trials, and for external rotation and adduction moments in the v-cutting trials. Knee moments were greater in v-cut than running, and the traditional soccer cleats (Copa Mondial and World Cup) tended to result in greater knee moments than the Nova runner or TRX soccer cleat. Cleat design was found to influence 3-dimensional knee moments in a v-cut maneuver. In the translational traction test, there were significant differences between all conditions. In the rotational traction test, friction with soccer shoes were greater than friction with running shoes. However, no differences were found between soccer shoes. Higher moments may lead to increased loads and stresses on knee joint structures, and thus, greater injury rates.

전방 점프 착지 시 만성 발목 불안정성이 자세 조절에 미치는 영향 (The Effects of Chronic Ankle Instability on Postural Control during Forward Jump Landing)

  • Kim, Kew-wan;Jeon, Kyoungkyu;Park, Seokwoo;Ahn, Seji
    • 한국운동역학회지
    • /
    • 제32권1호
    • /
    • pp.9-16
    • /
    • 2022
  • Objective: The purpose of this study was to investigate how the chronic ankle instability affects postural control during forward jump landing. Method: 20 women with chronic ankle instability (age: 21.7 ± 1.6 yrs, height: 162.1 ± 3.7 cm, weight: 52.2 ± 5.8 kg) and 20 healthy adult women (age: 21.8 ± 1.6 yrs, height: 161.9 ± 4.4 cm, weight: 52.9 ± 7.2 kg) participated in this study. For the forward jump participants were instructed to stand on two legs at a distance of 40% of their body height from the center of force plate. Participants were jump forward over a 15 cm hurdle to the force plate and land on their non-dominant or affected leg. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and joint angle, vertical ground reaction force and center of pressure. All statistical analyses were using SPSS 25.0 program. The differences in variables between the two groups were compared through an independent sample t-test, and the significance level was to p < .05. Results: In the hip and knee joint angle, the CAI group showed a smaller flexion angle than the control group, and the knee joint valgus angle was significantly larger. In the case of ankle joint, the CAI group showed a large inversion angle at all events. In the kinetic variables, the vGRF was significantly greater in the CAI group than control group at IC and mGRF. In COP Y, the CAI group showed a lateral shifted center of pressure. Conclusion: Our results indicated that chronic ankle instability decreases the flexion angle of the hip and knee joint, increases the valgus angle of the knee joint, and increases the inversion angle of the ankle joint during landing. In addition, an increase in the maximum vertical ground reaction force and a lateral shifted center of pressure were observed. This suggests that chronic ankle instability increases the risk of non-contact knee injury as well as the risk of lateral ankle sprain during forward jump landing.

비탄력 테이핑이 슬개대퇴관절 통증증후군 환자의 슬개건 통증과 슬관절부 근력, 보행에 미치는 영향 비교 (Comparison of the Effects of Non-elastic Taping on Patellar tendon Pain, Knee Muscle Strength and Gait in Patients with Patellofemoral Joint Pain Syndrome)

  • 정상모;정영준;안승원
    • 대한정형도수물리치료학회지
    • /
    • 제25권2호
    • /
    • pp.39-46
    • /
    • 2019
  • Background: Ground repulsion or impact on the ground during daily activities, sports, or occupational activities may cause injury to the knee when walking. Non-elastic taping is effective in treating these problems in previous studies. Non-elastic taping strengthens the structure of the soft tissues of the injured knee joint to maintain constant tension, improves muscle rearrangement and function, and improves proprioception. Based on previous studies, we intended to see the therapeutic changes of non-elastic taping in patients with patellofemoral joint pain syndrome. Methods: The non-elastic taping application method was applied to the patient three times for five hours for one week. Non-elastic taping was applied to the patellar tendon with little space above the skin segment of the patellar femur, with both sides fixed by taping. Muscle strength and gait change were evaluated with non-elastc taping. Results: The knee flexion, extension strength and gait evaluation of the knee joint with inelastic taping showed significant differences after treatment. There was a significant difference in the comparison between the two groups after the treatment method was applied (p<.05). Conclusion: As a result, this study confirms that the non-elastic taping method applied for the treatment of patellar femoral joint pain syndrome is effective in the treatment.

전방십자인대 손상의 치료 원칙 (Treatment Principles of Anterior Cruciate Ligament Injury)

  • 하권익
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.36-40
    • /
    • 1997
  • Anterior Cruciate Ligament (ACL) plays an important biomechanical role for the stability of knee joint. ACL injury often leads to injuries of articular cartilage, menisci, or other supporting structures, and subsequent development of degenerative arthritis. Controversies still exist in the best treatment modalities of ACL injuries. hut the author considers it most important to make the appropriate patient selection for operative reconstruction or nonoperative treatment. and describes the treatment principles of ACL injury, including diagnosis, patient selection and the treatment modalities for successful treatment of ACL injury.

  • PDF

무릎 굴곡 및 후방 관절낭 절제술이 슬와 동맥의 위치에 주는 영향 (The Effect of Knee Flexion and Posterior Septal Release on the Location of Popliteal Artery)

  • 서승석;서진혁;김창완;권용욱
    • 대한정형외과스포츠의학회지
    • /
    • 제11권2호
    • /
    • pp.69-74
    • /
    • 2012
  • 목적: 슬관절의 신전 또는 굴곡 시 슬와 동맥의 위치 변화를 확인하고 슬관절의 후방 관절낭 유리술을 시행 후의 슬와 동맥의 위치 변화를 측정하여 슬관절 수술 시 슬와 동맥의 손상을 최소화 할 수 있는 자세 및 후방 관절낭 유리술의 유용성에 대해 알아보고자 하였다. 대상 및 방법: 중년의 남성 및 여성, 총 2구의 신선 동결 전신 사체로서, 모두 4례의 슬관절을 대상으로 하였다. 슬관절을 0도, 30도, 60도, 90도 각도로 굴곡하여, 각각의 각도에서 관절면 및 관절면으로부터 원위 1 cm 및 2 cm에서 경골 후방 피질골로 부터 슬와 동맥과의 거리를 측정하였다. 관절경을 이용하여 후방 관절낭 유리술을 시행하였고, 같은 방법으로 경골 후방 피질골로부터 슬와 동맥과의 거리를 측정하였다. 결과: 슬와 동맥에서 후방 경골 피질까지의 거리는 관절면, 관절면 원위 1 cm, 관절면 원위 2 cm에서 0도 굴곡 시 평균 6.3 mm (4.5~7), 4.6 mm (3.6~6), 4.9 mm (3.9~5.8), 30도 굴곡 시 평균 7.4 mm (5.2~9), 4.9 mm (3.6~7.2), 5.3 mm (3.8~6.6), 60도 굴곡 시 평균 8.7 mm (5.4~11), 5.2 mm (4.9~7.3), 6.2 mm (5.4~9.6), 90도 굴곡 시 9.8 mm (5.8~12.1), 5.5 mm (5.1~7.4), 6.5 mm (5.4~10.7) 이었다. 후방 관절낭 유리술 시행 후에는 관절면, 관절면 원위 1 cm, 관절면 원위 2 cm에서 0도 굴곡 시 6.5 mm (5.5~7.5), 5.8 mm (3.9~7.2), 5.2 mm (3.8~7.0), 30도 굴곡 시 7.7 mm (5.5~9,1), 7.1 mm (4.6~7.6), 5.5 mm (4.1~6.9), 60도 굴곡 시 8.9 mm (5.7~11.2), 8.5 mm (5.5~9.2), 6.4 mm (5.3~10.1), 90도 굴곡 시 10.2 mm (6.3~13.6), 9.5 mm (6.5~11), 6.6 mm (5.9~9.8)로 측정되었다. 결론: 슬관절을 굴곡시킬수록 슬관절 관절면에서 관절면 원위 2 cm 사이에서는 경골 후방 피질골과 슬와 동맥 사이의 거리를 증가되어 슬관절 수술시 슬와 동맥 손상을 줄일 수 있다. 또한 후방 관절낭 유리술을 시행하게 되면 경골 후방 피질골과 슬와 동맥 사이의 거리를 더 증가시켜 슬와 동맥 손상을 보다 더 줄일 수 있을 것이다.

  • PDF