• Title/Summary/Keyword: Knee Bone

Search Result 292, Processing Time 0.157 seconds

The Effect of Bee Venom Pharmacopuncture Therapy on the Condition of Different Concentration in Rheumatoid Arthritis Rat Model (흰쥐의 류마티스 관절염 모델에서 봉약침의 농도별 처리 조건에 따른 치료 효과)

  • You, Deok-Seon;Yeom, Seung-Ryong;Lee, Su-Kyung;Kwon, Young-Dal;Song, Yung-Sun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.101-123
    • /
    • 2011
  • Objectives : The aim was to study the effect of bee venom pharmacopuncture therapy with different concentration on rheumatoid arthritis rat model. Methods : We enforced a bee venom pharmacopuncture therapy with different concentration on rheumatoid arthritis rat model by the intradermal injection of chicken type II collagen emulsified. 14 days after the onset of the rheumatoid arthritis rat model, a fixed volume of bee venom was daily injected to ST-35 acupoint in the rat's knee joint for 2-3 weeks. The hind paw volume, arthritic index, arthritic flexion pain test, pain threshold, and serum analysis (CRP, $PGE_2$, ALT, AST) were analyzed, and the expression profiles of COX-2, c-fos, and substance-P at the dorsal horn region of the spinal cord and subchondral bone of the knee joint were also analyzed by using the immunohistochemistry. Results : After the treatment of rheumatoid arthritis rats with bee venom pharmacopuncture, the paw volume of edema of arthritic rats were almost restored to the level of normal group, and behavior tests were very effective. Also the evaluation on the blood serum analysis was remarkable. COX-2, c-fos, and substance-P positive cells in the immunohistological section of dorsal horn region of the spinal cord and subchondral bone of the knee joints were significantly decreased. also the bee venom pharmacopuncture was effective to alleviate their rheumatoid arthritic inflammation cytokine inhibition as regards to the behavior tests and joint histological appearance. Conclusions : Based on the results in this study, bee venom pharmacopuncture with concentrated treatment condition was very effective in low fixed quantity and progressive low increased quantity.

Reconstruction of Anterior Cruciate Ligament With Bone-Patellar tendon-Bone Allograft (동종 슬개건을 이용한 전방십자인대 재건술)

  • Chun, Churl Hong;Lee, Byoung Chang;Kim, Young Jin;Yang, Hwan Duk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.102-108
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the clinical results of bone-patellar tendon-bone(B-PTB) allograft for ACL reconstruction without mechanical tensioning device. Material and Method : Forty-six knees in 43 patients were reviewed and evaluated with subjective evaluation, objective evaluation, Telos stress arthrometer and modified Feagin Scoring System. The average age at the time of operation was 27 years(range, 18-42) and the average follow up period was 41 months(range, 22-79). Authors reconstructed ACL using B-PTB allograft which was prepared by rehydration preoperatively without tensioning by mechanical tensioning device. The tension for allograft was obtained by full flexion and extension intraoperatively. All operation were performed arthroscopically by two-tunnel method to avoid the mismatching of allograft tendon length. Result : The modified Feagin Scoring System revealed 39 cases(84.7%) with excellent or good results and 7 cases(15.3%) with fair or poor results. The mean follow-up Lysholm Knee Score was 84. Telos arthrometer revealed 41 cases had an injured-to-uninjured difference of 5 mm or less(mean 2.3mm). The range of motion of knee was nearly normal and there was no extension lag in any cases at last follow up. Conclusion : Clinical results using B-PTB allograft showed less morbidity than B-PTB autograft. The intraoperative tensioning method by full flexion and extension without mechanical tensioning device was not bad. Therefore, B-PTB allograft is a good substitute material in reconstruction of the ACL.

  • PDF

Breakage of Core Reamer During Anterior Cruciate Ligament Reconstruction -A Case Report- (자가 슬개건을 이용한 전방십자인대 재건술 시 경골터널 생성중 핵심 확공기의 파열 - 증례보고 -)

  • Noh, Jung-Ho;Yang, Bo-Kyu;Park, Jung-Tae;Je, Min-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.33-35
    • /
    • 2010
  • This is a case of the core reamer breakage during anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. A 19-year-old man with acute anterior cruciate ligament rupture had reconstruction surgery. During tunneling in the proximal tibia, the core reamer have been cracked open and broken. Rest of the procedure was performed routinely except the tibial sided fixation of bone block which was performed with larger interference screw than usual. The patient followed the accelerated rehabilitation program. The result was satisfactory at 2 years after surgery.

  • PDF

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

Technical Note of Meniscal Allograft Transplantation using Minimal Incision (최소 절개술에 의한 반월상 연골 동종이식 수술기법)

  • Min, Byoung-Hyun;Kim, Ho Sung;Jang, Dong Wok;Kang, Shin Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The current treatment of extensive meniscal injuries has resulted in numerous investigations and clinical trials to restore normal meniscal functions. A cryopreserved meniscal allograft transplantation is one of the successful methods available to restore the meniscus. All the procedures of 26 cases were performed in an minimal open fashion, though initial four cases were done with the aid of arthroscope. In all of the grafts, we used a bone bridge which was attached to meniscus for better stability and healing. Anterior cruciate ligament reconstructions were also performed simultaneously with the meniscal procedures. We attempted to minimize articular cartilage by employing so called the "Key-hole technique" for the medial meniscus transplantation. First, the meniscal cartilage bone bridge was shaped into a cylinder and a bone tunnel was made just beside the medial border of the anterior criciate ligament insertion of the recipient knee joint, and the bone bridge of the meniscal cartilage was push to press-fit. The inserted meniscal cartilage was sutured by the usually employed technique under arthroscopic control. The lateral meniscus was shaped different to the medial meniscus in that the bone bridge was semicylindrical and the bone trough was made beside the lateral border of the anterior criciate ligament insertion of the recipient knee joint. The meniscus was put into the bone trough and the leading suture was extracted anterior to the tibia and tied the knot. The inserted meniscus was sutured in the same manner as the medial meniscus transplantation. By the above described method, the authors were able to minimize the articular cartilage invasion and transplant the meniscus with relative accuracy.

  • PDF

Integration of Four-Strand Hamstring Tendon Graft with Bone in Reconstruction of the Anterior Cruciate Ligament -Report of one case- (슬괵건을 이용한 전방십자인대 재건술시 이식건과 골 사이의 골통합에 대한 조직학적 변화 - 1례 보고 -)

  • Jung, Young-Bok;Jang, Eui-Chan;Yum, Jae-Kwang;Park, Geun-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.40-43
    • /
    • 1999
  • Arthroscopic anterior cruciate ligament(ACL) reconstruction using four-strand hamstring tendon with looping around transfixing screw in femoral tunnel requires osteointegration between the grafted tendon and bone for stability of the knee. Authors have experienced a histologic finding of osteointegration between the grafted autogenous hamstring tendon and bone in femoral tunnel after arthroscopic ACL reconstruction. A patient received arthroscopic ACL reconstruction with autogenous four strand hamstring tendon for the ACL injury. Traumatic re-rupture of mid-substance of ACL graft was developed at thirteenth week after operation. During the procedures of arthroscopic revision at fifteenth week after initial ACL reconstruction, biopsy was performed at the site of interface between grafted tendon and bone in femoral tunnel. Integration between the grafted tendon and bone was evident by demonstrating the continuity of collagen fiber between bond and tendon. This histologic finding and the low incidence of early graft failure suggest that free tendon autograft attached to bone by looping around a transfixing screw in femoral tunnel undergoes adequate osteointegration between 12 and 15 weeks after surgery and authors thought that insertion of bone chip into the femoral tunnel would accelerate osteointegration procedure.

  • PDF

Do the Rotating Hinge-Flexible Intramedullary Nail Composites Alleviate Junctional Osteolysis in Megaprothesis Reconstruction for Bone Tumor? (탄력성 있는 골수강 내고정물과 회전경첩형 슬관절 전치환물을 조합한 종양인공관절로 자가골의 골 용해를 감소시킬 수 있는가?)

  • Song, Won-Seok;Cho, Wan-Hyeong;Cho, Sang-Hyun;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.2
    • /
    • pp.96-104
    • /
    • 2007
  • Purpose: The authors investigated whether 35 flexible nail-rotating hinge composite reconstructions around knee joint minimize junctional osteolysis of host bone. Material and Method: The reconstructive technique was as follows: 1) en bloc tumor resection, 2) filling of the host bone marrow cavity with multiple Ender nails, 3) assembling the Ender nails and an Endo-Link type total knee component with wire and bone cement. Result: Mean follow-up was 53 months (ranged 30~79). At final follow-up, 29 patients retained a mobile joint. Resection of more than 40% of bone showed a positive relationship with junctional hypertrophy (p=0.028). Eight patients showed nail breakage and eight prostheses were removed due to early or late infection. The cumulative prosthetic survival rate was 33% at 6 year. Average functional score according to the MSTS criteria was 26.8. Conclusion: Mid-term evaluations showed that results were fair. The revision process was straightforward. Junctional hypertrophy observed appears to give some clues as to how to minimize osteolysis at the prosthesis-host junction after modular prosthesis fixation.

  • PDF

Automatic Bone Segmentation from CT Images Using Chan-Vese Multiphase Active Contour

  • Truc, P.T.H.;Kim, T.S.;Kim, Y.H.;Ahn, Y.B.;Lee, Y.K.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.713-720
    • /
    • 2007
  • In image-guided surgery, automatic bone segmentation of Computed Tomography (CT) images is an important but challenging step. Previous attempts include intensity-, edge-, region-, and deformable curve-based approaches [1], but none claims fully satisfactory performance. Although active contour (AC) techniques possess many excellent characteristics, their applications in CT image segmentation have not worthily exploited yet. In this study, we have evaluated the automaticity and performance of the model of Chan-Vese Multiphase AC Without Edges towards knee bone segmentation from CT images. This model is suitable because it is initialization-insensitive and topology-adaptive. Its segmentation results have been qualitatively compared with those from four other widely used AC models: namely Gradient Vector Flow (GVF) AC, Geometric AC, Geodesic AC, and GVF Fast Geometric AC. To quantitatively evaluate its performance, the results from a commercial software and a medical expert have been used. The evaluation results show that the Chan-Vese model provides superior performance with least user interaction, proving its suitability for automatic bone segmentation from CT images.

Reconstruction of Extensor Mechanism After Prosthetic Replacement of The Proximal Tibia (근위 경골에 발생한 악성종양 절제 후 슬관절 신전력 재건술 -증례 보고-)

  • Park, Jong-Hoon;Oh, Jung-Moon;Kim, Jin-Wook;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.120-123
    • /
    • 2004
  • Benign and malignant bone tumors occur most commonly around the knee. The proximal tibia is the most technically demanding site for limb salvage surgery. The most difficult problem using an endoprothesis for proximal tibial resection has been reconstruction of the extensor mechanism. After excision of proximal tibia, we resected distal femur and made a composite with resected distal femur, low heat treated autogenous proximal tibia and endoprothesis. Patella was fixed into the resected down-loaded distal femur. This article shows the new technique and the results of reconstruction of extensor mechanism after prosthetic replacement of the proximal tibia.

  • PDF

Stress fracture in Vascularized fibular Grafts (혈관 부착 이식 비골에 발생한 피로골절)

  • Kim, Hyoung-Min;Kim, Youn-Soo;Lee, Kee-Haeng;Jeong, Chang-Hoon;Kim, Jun-Seok
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.1
    • /
    • pp.18-22
    • /
    • 2001
  • Purpose : The purpose of this study was to evaluate stress fracture of vascularized fibular grafts(VFG) by analyzing factors associated with stress fracture and the treatment results. Materials and Methods : From June 1985 to May 1998, 7 patients with stress fractures in the 38 patients with long bone defect who had vascularized fibular graft were evaluated with clinical and radiologic methods including grafted fibular length and hypertrophic index of de Boer. The average age of the patients was 35 years(range, $14{\sim}60$ years). The mean follow-up period was 20 months(range, $16{\sim}32$ months). Results: 7(18.4%) stress fractures occurred in 38 patients. Characteristics of the fractures were (1) all occurred at lower extremity of male patients treated with VFG for long bone defected caused by infected nonunion; (2) all occurred 10 months at the average(range, $4{\sim}17$ months) after VFG; and (3) the length and hypertrophic index of grafted fibula had no influence on the incidence of stress fracture. Union was obtained in 3 patients by conservative treatment. 4 patients obtained union by internal fixation; one at immediately onset of fracture; and three after failure of conservative treatment who had fracture around the knee joint. Conclusion : Stress fracture may occur during the first one year after vascularized fibular graft and more attention must be paid for prevention of it, especially in the cases of infected nonunion. Stress fracture around the knee joint was expected to lead to a good result of early union by operative treatment.

  • PDF