• 제목/요약/키워드: Kinematic measurement

검색결과 183건 처리시간 0.024초

칩마운터를 위한 통합 오차 측정 및 평가 시스템 개발에 관한 연구 (A study on the development of the integrated error measurement and calibration system for a chip mounter)

  • 이동준;문준희;박희재;정상호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.366-370
    • /
    • 2002
  • A kinematic ball bar measurement system can analyze the various errors of a machine tool easily and rapidly in a procedure and can measure many types of equipment such as chip mounter, PCB router, precision stage, etc. In this paper, the thermally induced errors are loused among various errors of a chip mounter because it affects the accuracy of the machine very much. Linear regression technique is adapted for the thermal error modeling. While the measurement and calibration of a chip mounter is difficult in general, this developed system is not only easy to apply for it but also improves the accuracy by 4 times or more.

  • PDF

A New Device and Procedure for Kinematic Calibration of Parallel Manipulators

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1615-1620
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise. Intrinsic inaccuracies of the device can significantly deteriorate the calibration results. A measurement procedure is proposed and formulations of cost functions are discussed to prevent propagation of the inaccuracies to the calibration results.

  • PDF

Experimental Results of Ship's Maneuvering Test Using GPS

  • Yoo, Yun-Ja;Naknma, Yoshiyasu;Kouguchi, Nobuyoshi;Song, Chae-Uk
    • 한국항해항만학회지
    • /
    • 제33권2호
    • /
    • pp.99-104
    • /
    • 2009
  • The Kinematic GPS is well known to provide a quite good accuracy of positioning within an level. Although kinematic GPS assures high precision measurement on the basis of an appreciable distance between a reference station and an observational point, it has measurable distance restriction within 20 km from a reference station on land. Therefore, it is necessary to make out a simple and low-cost method to obtain accurate positioning information without distance restriction In this paper, the velocity integration method to get the precise velocity information of a ship is explained. The experimental results of Zig-zag maneuver and Williamson turn as the ship's maneuvering test, and other experimental results of ship's movement during leaving and entering the port with low speed were shown. From the experimental results, ship's course, speed and position are compared with those obtained by kinematic-GPS, velocity integration method and dead reckoning position using Gyro-compass and Doppler-log.

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

여유구동 병렬기구의 기구학적 보정 (Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms)

  • 정재일;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

A Study on the Applicability of the Kinematic and the Static GPS Methods for Coastal Ocean Structure Survey

  • Lee, Byung-Gul;Yang, Sung-Kee;Kang, In-Jun
    • 한국환경과학회지
    • /
    • 제11권2호
    • /
    • pp.103-110
    • /
    • 2002
  • The position fixing usually is determined by triangulation, traverse surveying and astronomy surveying. However, when the station is moving, it is impossible to determine its position continuously by the former method. By a satellite positioning method(GPS), this problem can be solved. In our study, we used two methods to determine the length and coordinate of a point position. One is a kinematic GPS method and the other is a static one. Each is based on carrier phase measurement and employs a relative position technique. We implemented observation experiments such as Geodimeter and DGPS(Differential GPS) successfully. To estimate the accuracy between the kinematic and static methods, we compared the results of Geodimeter, the kinematic, and the static. The results showed that the static is relatively a little more accurate than the kinematic. However, in the kinematic mode, when we received the GPS data for a long time, we found that the kinematic also had a high accuracy value for the length survey Finally, we applied the GPS to Jeju Harbor Breakwater to examine the applicability of GPS for coastal ocean structure based on the kinematics and the statics, respectively.

Grid Encoder를 이용한 NC공작기계 동적정밀도 측정에 관한 연구 (A Study on Measurement of Dynamic Accuracy Using Grid Encoder in NC Machine Tools)

  • 이찬호;이방희;김성청
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.378-381
    • /
    • 2003
  • Efficient development of method on a performance evaluation for machine tools has been regarded as the most important work for accuracy and quality enhancement to every user and manufacturer. A evaluation method of accuracy for machine tools has been studied recently according to the rapid increase of interest in precision machine tools. To this point of view, the circular interpolation test of machine tools is recognized as the most useful method to distinguish a dynamic accuracy of NC machine tools by ISO and ANSI/ASME, etc. In this paper, we have studied and developed the form measurement system with grid encoder to analyse the final accuracy of NC machine tools. we have analyzed the servo system error and geometric error of NC machine tools through measuring a dynamic error signal by this system. and then we verified the experimental result and enhanced the reliability by means of comparing the characteristics of the developed system with the kinematic ball-bar system.

  • PDF

3D 가변 선회 모델 및 기구학적 구속조건을 사용한 기동표적 추적 (Maneuvering Target Tracking With 3D Variable Turn Model and Kinematic Constraint)

  • 김남수;이동우;방효충
    • 한국항공우주학회지
    • /
    • 제48권11호
    • /
    • pp.881-888
    • /
    • 2020
  • 본 논문에서는 관측자가 얻을 수 있는 시선각(LOS) 측정값을 사용하여 관심표적의 상태변수를 추정하는 연구를 수행하였다. 관심상태변수는 표적의 위치, 속도 및 가속도로 설정하였다. 시선각 측정값은 필터에 표적운동모델 적용을 어렵게 하는 비선형성이 강한 측정값이다. 이러한 문제해결을 위해 가측정치 공식(Pseudomeasurement equation)을 사용하여 시선각 측정값 수식을 변경한 후 3D 가변선회(3D Variable Turn) 표적운동모델을 적용하였다. 또한 필터의 성능을 위해 기구학적구속조건(Kinematic Constraint)을 적용하였다. 필터는 초기조건에 강건한 특성을 가진 Bias Compensation Pseudomeasurement Filter (BCPMF)를 사용하였다. 병렬 계산의 이점을 위해 Two Stage Kalman Filter 형태를 추가적으로 적용하였다. 이 기법들을 사용하여 TBCPMF 3DVT-KC 필터를 제안하였고 시뮬레이션을 통해 성능을 확인하였다.

Kinematic Calibration of a Cartesian Parallel Manipulator

  • Kim, Han-Sung
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권3호
    • /
    • pp.453-460
    • /
    • 2005
  • In this paper, a prototype Cartesian Parallel Manipulator (CPM) is demonstrated, in which a moving platform is connected to a fixed frame by three PRRR limbs. Due to the orthogonal arrangement of the three prismatic joints, it behaves like a conventional X-Y-Z Cartesian robot. However, because all the linear actuators are mounted at the fixed frame, the manipulator may be suitable for applications requiring high speed and accuracy. Using a geometric method and the practical assumption that three revolute joint axes in each limb are parallel to one another, a simple forward kinematics for an actual model is derived, which is expressed in terms of a set of linear equations. Based on the error model, two calibration methods using full position and length measurements are developed. It is shown that for a full position measurement, the solution for the calibration can be obtained analytically. However, since a ball-bar is less expensive and sufficiently accurate for calibration, the kinematic calibration experiment on the prototype machine is performed by using a ball-bar. The effectiveness of the kinematic calibration method with a ball-bar is verified through the well­known circular test.

GPS에 의한 장기선 이동측량의 효율성 검토 (A Study on the Effective Use of Long-Baseline Kinematic Surveying by GPS)

  • 강준묵;이용욱;박정현
    • 대한공간정보학회지
    • /
    • 제8권2호
    • /
    • pp.101-108
    • /
    • 2000
  • 단시간으로 많은 3차원 지형정보를 획득할 수 있는 GPS 이동측량은 수 km 이하의 단기선에서 주로 활용되고 있으며, 장기선에 대한 위치결정은 비교적 오랜 시간이 요구되는 정지 측량에 의존하고 있어 단시간으로 장기선 위치결정을 할 수 있는 방법이 요구되고 있다. 본 연구는 GPS에 의한 장기선 이동측량의 효율적 이용 가능성을 검토하기 위하여 수 십 km 이상의 기선에 대한 기선 거리별, 궤도력별 그리고 관측시간대별로 기선해석 정확도를 정지측량 결과와 비교 분석하고자 한다. 연구결과, cycle slip이 발생한 경우 기선해석 정확도가 크게 저하됨을 알 수 있었다 정밀궤도력을 이용한 경우 70km 이내에서 수 분의 이동측량으로 1ppm 이하의 정확도를 얻을 수 있었다. 앞으로 좀더 심도 있는 연구가 수행된다면, 수 십 km 이내에서 GPS 이동측량을 이용하여 국토개발을 비롯한 각종 건설분야에 필요한 지형정보를 보다 효율적으로 획득할 수 있을 것으로 기대된다.

  • PDF