• Title/Summary/Keyword: Key-insulated

Search Result 26, Processing Time 0.019 seconds

Semi-Insulating SiC Single Crystals Grown with Purity Levels in SiC Source Materials (고순도 SiC 파우더를 이용한 반절연 SiC 단결정 성장)

  • Lee, Chae Young;Choi, Jeong Min;Kim, Dae Sung;Park, Mi Seon;Jang, Yeon Suk;Lee, Won Jae;Yang, In Seok;Kim, Tae Hee;Chen, Xiufang;Xu, Xiangang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.100-103
    • /
    • 2019
  • The change in vanadium amount according to the growth direction of vanadium-doped semi-insulated (SI) SiC single crystals using high-purity SiC powder was investigated. High-purity SiC powder and a porous graphite (PG) inner crucible were placed on opposite sides of SiC seed crystals. SI SiC crystals were grown on 2 inch 6H-SiC Si-face seeds at a temperature of $2,300^{\circ}C$ and growth pressure of 10~30 mbar of argon atmosphere, using the physical vapor transport (PVT) method. The sliced SiC single crystals were polished using diamond slurry. We analyzed the polytype and quality of the SiC crystals using high-resolution X-ray diffraction (XRD) and Raman spectroscopy. The resistivity of the SI SiC crystals was analyzed using contactless resistivity mapping (COREMA) measurements.

Design and Process Development in High Voltage Insulated Gate Bipolar Transistors (IGBTs)

  • Kim, Su-Seong
    • The Magazine of the IEIE
    • /
    • v.35 no.7
    • /
    • pp.57-71
    • /
    • 2008
  • The last decade has witnessed great improvements in power semiconductor devices thanks to the advanced design and process, which have made it possible to significantly improve the electrical performances of electronic systems while simultaneously reducing their site, weight and perhaps most importantly reducing their cost. Among the power semiconductor devices, IGBT will be a key semiconductor component for power industry since it has a huge potential to cover large areas of power electronics from small home appliances to heavy industries. Currently, only a few limited power semiconductor manufacturers supply most of the industrial consumptions of power IGBT and its modules. Therefore, a large portion of technology in the power industry is dependent on other advanced countries. In this regard, to independently build power IGBT devices and the relevant power module technology, Korean government initiated a new 5-year project 'Power IT,' which also aimed at booming the business of the power semiconductor and the allied industries. With the success of this power IT project, it is expected that the power semiconductor technology will be a basis to foster the high power semiconductor industry and moreover, there will be more innovative developments in the Korea region and globally Also, forming the channel between the customers and suppliers, it is possible to effectively develop the customized power products, which could strengthen the competitiveness of Korean power industry. Furthermore, the power industry including semiconductor manufacturers will be technologically self-supporting and be able to obtain good business opportunities, and eventually increase the share in the growing power semiconductor market, which could be positioned as a major industry in Korea.

  • PDF

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

Development of Large Propulsion Motor Bearings Considering Slope Conditions (경사조건을 고려한 대용량 추진 전동기용 베어링 개발에 대한 연구)

  • Oh, Seung Tae;Choi, Jin Woo;Kang, Byeng Hi;Kim, Jin;Choi, Seong Pil;Bin, Jae Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.241-248
    • /
    • 2013
  • In this study, bearings were developed for a high-power propulsion motor operating in inclined operation conditions through a simulation and similitude-experimental methods using commercial rotating machinery dynamics analysis software. The developed journal bearing is electrically insulated and has low thermal conductivity because each part is connected with 2-4 -mm-thick epoxy plates. To realize an appropriate oil thickness, an oil lift system is adopted, and a half separated structure is applied to ensure the feasibility of maintaining very heavy components. This study discusses some of the key design aspects of sleeve bearing design for high-torque and low-speed propulsion motor applications. Furthermore, the conditions of variable slope tests are examined to prevent oil leakage from the bearing lip seal on the test rig.

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

Thoracoscopic Sympathectomy for a Patient with Facial Hyperhidrosis -A case report- (흉강경하 흉부교감신경절제술을 이용한 안면다한증 치료 -증례보고-)

  • Moon, Dong-Eon;Park, Byung-Cheul;Kim, Byung-Chan;Kim, Sung-Nyeon
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.399-402
    • /
    • 1996
  • Endoscopic transthoracic sympathectomy (ETS) has recently become estabilished as a successful treatment for severe palmar and axillary hyperhidrosis. Descriptions have been published of neurolytic, operative and alternative endoscopic procedures involving thermocoagulation, laser coagulation, or or nonvideo-assisted ganglionectomy using equipment not widely available, with low morbidity and excellent results. All methods have advantage and disadvantages. A 19-year-old male who suffered from severe hyperhidrosis on face, palms and axillary areas, has been initially treated with stellate ganglion block in other pain clinic. He was transfered to our pain clinic for endoscopic thoracic sympathectomy. The patient was intubated left side 34 Fr. double lumen tube and positioned left semi-lateral position for right sympathectomy. Right side pneumothorax was created by clamping the ipsilateral side of the double lumen tube and aspiration of air. 11-mm trocar was introduced through incision at the third intercostal space in anterior axillary line, and then additional two 11-mm and 5-mm trocar was introduced through second and fifth intercostal space in mid axillary line. The lung was gently retracted and the parietal pleura over the heads of the appropriate ribs excised using 5-mm sharp insulated coagulating microprocesss. The T4, T3, and T2 ganglions, as well as accompanying rami communicantes, and other branchs arising from upper thoracic nerves to the brachial plexus and surrounding tissues were carefully dissected, coagulated. During sympathectomy, skin temperature of middle was continuously monitored. Elevation of palmar skin temperature intraoperatively indicated an adequate sympathectomy with a definite therapeutic effect. A No. 28 Fr. thoracotomy tube was introduced through a troca under video guidance, placed under water seal after the lung was reinflated. the controlateral side was performed same procedure. After bilateral sympathectomy, chest tubes were removed, and then, he was discharged 2 days after operation with great satisfaction. The ETS provides a well-tolerated, cost-effective alternative to thoracic sympathectomy for primary hyperhidrosis and sympathetic mediated neuropathic pain disorder. And T2 ganglion is considered the key ganglion for the treatment of primary hyperhidrosis. The low incidence of compensatory sweating may by explained by the limited extent of the sympathectomy.

  • PDF