• Title/Summary/Keyword: Key-hole method

Search Result 45, Processing Time 0.026 seconds

The Phenomenological Comparison between Results from Single-hole and Cross-hole Hydraulic Test (균열암반 매질 내 단공 및 공간 간섭 시험에 대한 현상적 비교)

  • Kim, Tae-Hee;Kim, Kue-Young;Oh, Jun-Ho;Hwang, Se-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.39-53
    • /
    • 2007
  • Generally, fractured medium can be described with some key parameters, such as hydraulic conductivities or random field of hydraulic conductivities (continuum model), spatial and statistical distribution of permeable fractures (discrete fracture network model). Investigating the practical applicability of the well-known conceptual models for the description of groundwater flow in fractured media, various types of hydraulic tests were applied to studies on the highly fractured media in Geumsan, Korea. Results from single-hole packer test show that the horizontal hydraulic conductivities in the permeable media are between $7.67{\times}10^{-10}{\sim}3.16{\times}10^{-6}$ m/sec, with $7.70{\times}10^{-7}$ m/sec arithmetic mean and $2.16{\times}10^{-7}$ m/sec geometric mean. Total number of test interval is 110 at 8 holes. The number of completely impermeable interval is 9, and the low permeable interval - below $1.0{\times}10^{-8}$ m/sec is 14. In other words, most of test intervals are permeable. The vertical distribution of hydraulic conductivities shows apparently the good correlation with the results of flowmeter test. But the results from the cross-hole test show some different features. The results from the cross-hole test are highly related to the connectivity and/or the binary properties of fractured media; permeable and impermeable. From the viewpoint of the connection, the application of the general stochastic approach with a single continuum model may not be appropriate even in the moderately or highly permeable fractured medium. Then, further studies on the investigation method and the analysis procedures should be required for the reasonable and practical design of the conceptual model, with which the binary properties, including permeable/impermeable features, can be described.

Technical Note of Meniscal Allograft Transplantation using Minimal Incision (최소 절개술에 의한 반월상 연골 동종이식 수술기법)

  • Min, Byoung-Hyun;Kim, Ho Sung;Jang, Dong Wok;Kang, Shin Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The current treatment of extensive meniscal injuries has resulted in numerous investigations and clinical trials to restore normal meniscal functions. A cryopreserved meniscal allograft transplantation is one of the successful methods available to restore the meniscus. All the procedures of 26 cases were performed in an minimal open fashion, though initial four cases were done with the aid of arthroscope. In all of the grafts, we used a bone bridge which was attached to meniscus for better stability and healing. Anterior cruciate ligament reconstructions were also performed simultaneously with the meniscal procedures. We attempted to minimize articular cartilage by employing so called the "Key-hole technique" for the medial meniscus transplantation. First, the meniscal cartilage bone bridge was shaped into a cylinder and a bone tunnel was made just beside the medial border of the anterior criciate ligament insertion of the recipient knee joint, and the bone bridge of the meniscal cartilage was push to press-fit. The inserted meniscal cartilage was sutured by the usually employed technique under arthroscopic control. The lateral meniscus was shaped different to the medial meniscus in that the bone bridge was semicylindrical and the bone trough was made beside the lateral border of the anterior criciate ligament insertion of the recipient knee joint. The meniscus was put into the bone trough and the leading suture was extracted anterior to the tibia and tied the knot. The inserted meniscus was sutured in the same manner as the medial meniscus transplantation. By the above described method, the authors were able to minimize the articular cartilage invasion and transplant the meniscus with relative accuracy.

  • PDF

p-Type Activation of AlGaN-based UV-C Light-Emitting Diodes by Hydrogen Removal using Electrochemical Potentiostatic Activation (전기화학적 정전위 활성화를 사용한 수소 제거에 의한 AlGaN기반의 UV-C 발광 다이오드의 p-형 활성화)

  • Lee, Koh Eun;Choi, Rak Jun;Kumar, Chandra Mohan Manoj;Kang, Hyunwoong;Cho, Jaehee;Lee, June Key
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.85-89
    • /
    • 2021
  • AlGaN-based UV-C light-emitting diodes (LEDs) were applied for p-type activation by electrochemical potentiostatic activation (EPA). The p-type activation efficiency was increased by removing hydrogen atoms through EPA treatment using a neutral Mg-H complex that causes high resistance and low conductivity. A neutral Mg-H complex is decomposed into Mg- and H+ depending on the key parameters of solution, voltage, and time. The improved hole carrier concentration was confirmed by secondary ion mass spectroscopy (SIMS) analysis. This mechanism eventually improved the internal quantum efficiency (IQE), the light extraction efficiency, the leakage current value in the reverse current region, and junction temperature, resulting in better UV-C LED lifetime. For systematic analysis, SIMS, Etamax IQE system, integrating sphere, and current-voltage measurement system were used, and the results were compared with the existing N2-annealing method.

Arrangement of Agent Holes for Enhancing Crack Propagation in Structure Demolition Process using Soundless Chemical Demolition Agents (무소음화학팽창제를 이용한 구조물 해체시 균열진전 촉진을 위한 천공홀의 배치)

  • Nam, Yunmin;Kim, Kyeongjin;Park, Sanghyun;Sohn, Dongwoo;Lee, Jaeha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.683-690
    • /
    • 2015
  • For demolition of offshore facilities, traditional methods such as jackhammer and explosive methods have been often used in construction industry. However, prohibitions for use of those methods are becoming more rigorous especially in environmentally and historically sensitive areas. It was also reported that the explosive demolition method on maritime bedrock can cause a disturbance of ecosystem. For those reasons, use of soundless chemical demolition agent(SCDA) is getting the spotlight. However, researches regarding the mechanical point of SCDA have seldom performed. There is no industrial standard for use of SCDA yet. In this study, a pilot experimental study in order to measure the required expansive pressure that could be generated from SCDA was conducted. Numerical models were developed in order to estimate the required expansive pressures of SCDA for initiating cracks depending on selected key parameters. Obtained results indicate that the required pressure does not decrease linearly as increasing the hole diameter, the number of holes, and the ratio of hole-distance to hole-diameter.

Study on the mechanism for the dynamic traversing of multiple firewalls using the concept of one-time master key (일회용 마스터 키 개념을 이용한 다중 방화벽 동적 통과 메커니즘 연구)

  • Park, Hyoung-Woo;Kim, Sang-Wan;Kim, Jong-Suk Ruth.;Jang, Haeng-Jin
    • The Journal of Korean Association of Computer Education
    • /
    • v.13 no.5
    • /
    • pp.103-110
    • /
    • 2010
  • If an exterior computer wants to join the Grid/cloud computing platform for a while, all of the related firewalls' filtering rule should be immediately updated. As the platform of Internet application is gradually evolving into the Grid/Cloud environment, the R&D requirement for the dynamic traversing of the multiple firewalls by a single try is also increasing. In this paper, we introduce the new mechanism for the dynamic traversing of the multiple firewalls using the concept of the one-time master key that can dynamically unlock the tiers of firewalls simultaneously instead of the existed filtering rule based method like a lock management at each firewall. The proposed master keys are like one-time password, consisted of IP addresses, port numbers, and TCP's initial sequence numbers, and generated by end users not administrators. They're exchanged mutually in advance and used to make a hole at local-side firewalls for the other's packet incoming. Therefore, the proposed mechanism can function regardless of the number or type of firewalls.

  • PDF

AgI/AgCl/H2WO4 Double Heterojunctions Composites: Preparation and Visible-Light Photocatalytic Performance

  • Liu, Chunping;Lin, Haili;Gao, Shanmin;Yin, Ping;Guo, Lei;Huang, Baibiao;Dai, Ying
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.441-447
    • /
    • 2014
  • $AgI/AgCl/H_2WO_4$ double heterojunctions photocatalyst was prepared via deposition-precipitation followed by ion exchange method. The structure, crystallinity, morphology, chemical content and other physical-chemical properties of the samples are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive x-ray spectra (EDX), UV-vis diffuse reflectance spectroscopy (DRS), and photoluminescence (PL). The photocatalytic activity of the $AgI/AgCl/H_2WO_4$ was evaluated by degrading methyl orange (MO) under visible light irradiation (${\lambda}$ > 400 nm). The double heterojunctions photocatalyst displayed more efficient photocatalytic activity than pure AgI, AgCl, $H_2WO_4$ and AgCl/$H_2WO_4$. Based on the reactive species and energy band structure, the enhanced photocatalytic activity mechanism of $AgI/AgCl/H_2WO_4$ was discussed in detail. The improved photocatalytic performance of $AgI/AgCl/H_2WO_4$ double heterojunctions could be ascribed to the enhanced interfacial charge transfer and the inhibited recombination of electron-hole pairs, which was in close relation with the $AgI/AgCl/H_2WO_4$ heterojunctions formed between AgI, AgCl and $H_2WO_4$.

Measurement of Partial Conductivity of 8YSZ by Hebb-Wagner Polarization Method

  • Lim, Dae-Kwang;Guk, Jae-Geun;Choi, Hyen-Seok;Song, Sun-Ju
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.299-303
    • /
    • 2015
  • The electrolyte is an important component in determining the performance of Fuel Cells. Especially, investigation of the conduction properties of electrolytes plays a key role in determining the performance of the electrolyte. The electrochemical properties of Yttrium stabilized zirconia (YSZ) were measured to allow the use of this material as an electrolyte for solid oxide fuel cells (SOFC) in the temperature range of $700-1000^{\circ}C$ and in $0.21{\leq}pO_2/atm{\leq}10^{-23}$. A Hebb-Wagner polarization experimental cell was optimally manufactured; here we discuss typical problems associated with making cells. The partial conductivities due to electrons and holes for 8YSZ, which is known as a superior oxygen conductor, were obtained using I-V characteristics based on the Hebb-Wagner polarization method. Activation energies for holes and electrons are $3.99{\pm}0.17eV$ and $1.70{\pm}0.06eV$ respectively. Further, we calculated the oxygen ion conductivity with electron, hole, and total conductivity, which was obtained by DC four probe conductivity measurements. The oxygen ion conductivity was dependent on the temperature; the activation energy was $0.80{\pm}0.10eV$. The electrolyte domain was determined from the top limit, bottom limit, and boundary (p=n) of the oxygen partial pressure. As a result, the electrolyte domain was widely presented in an extensive range of oxygen partial pressures and temperatures.

Improved switching method for sensorless BLDC motor drive (Sensorless BLDC 전동기 구동을 위한 개선된 스위칭 방법)

  • Lee, Ho-Hyoung;Cho, Whang;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.164-170
    • /
    • 2010
  • In brushless DC motor, current flow should be controlled such that only properly selected 2 out of 3 phases carry current depending on the position of rotor. In order to detect position of rotor, hole sensor, encoder, optical position-detecting sensor, and magnetic position-detecting sensor are frequently employed. These sensors not only often cause malfunction in low and high temperature but they also have disadvantage of increasing cost and size of an motor system. To reduce the cost and size and to increase the robustness of the motor system, recently researches on sensorless motor dirve are very active. This paper proposes a novel unipolar PWM switching method that can improve the control problem caused by the difficulty of detecting zero crossing point at high revolution speed by minimizing the switching noise while increasing the lifespan of the drive system.

Efficient Attack Traffic Detection Method for Reducing False Alarms (False Alarm 감축을 위한 효율적인 공격 트래픽 탐지 기법)

  • Choi, Il-Jun;Chu, Byoung-Gyun;Oh, Chang-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.5
    • /
    • pp.65-75
    • /
    • 2009
  • The development of IT technology, Internet popularity is increasing geometrically. However, as its side effect, the intrusion behaviors such as information leakage for key system and infringement of computation network etc are also increasing fast. The attack traffic detection method which is suggested in this study utilizes the Snort, traditional NIDS, filters the packet with false positive among the detected attack traffics using Nmap information. Then, it performs the secondary filtering using nessus vulnerability information and finally performs correlation analysis considering appropriateness of management system, severity of signature and security hole so that it could reduce false positive alarm message as well as minimize the errors from false positive and as a result, it raised the overall attack detection results.

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.