• Title/Summary/Keyword: Ke

Search Result 1,707, Processing Time 0.038 seconds

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.

Gamma-ray Exposure Rate Monitoring by Energy Spectra of NaI(Tl) Scintillation detectors

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.158-165
    • /
    • 2017
  • Background: Nuclear facilities in South Korea have generally adopted pressurized ion chambers to measure ambient gamma ray exposure rates for monitoring the impact of radiation on the surrounding environment. The rates assessed with pressurized ion chambers do not distinguish between natural and man-made radiation, so a further step is needed to identify the cause of abnormal variation. In contrast, using NaI(Tl) scintillation detectors to detect gamma energy rates can allow an immediate assessment of the cause of variation through an analysis of the energy spectra. Against this backdrop, this study was conducted to propose a more effective way to monitor ambient gamma exposure rates. Materials and Methods: The following methods were used to analyze gamma energy spectra measured from January to November 2016 with NaI detectors installed at the Korea Atomic Energy Research Institute (KAERI) dormitory and Hanbat University. 1) Correlations of the variation of rates measured at the two locations were determined. 2) The dates, intervals, duration, and weather conditions were identified when rates increased by $5nSv{\cdot}h^{-1}$ or more. 3) Differences in the NaI spectra on normal days and days where rates spiked by $5nSv{\cdot}h^{-1}$ or more were studied. 4) An algorithm was derived for automatically calculating the net variation of the rates. Results and Discussion: The rates measured at KAERI and Hanbat University, located 12 kilometers apart, did not show a strong correlation (coefficient of determination = 0.577). Time gaps between spikes in the rates and rainfall were factors that affected the correlation. The weather conditions on days where rates went up by $5nSv{\cdot}h^{-1}$ or more featured rainfall, snowfall, or overcast, as well as an increase in peaks of the gamma rays emitted from the radon decay products of $^{214}Pb$ and $^{214}Bi$ in the spectrum. This study assumed that $^{214}Pb$ and $^{214}Bi$ exist at a radioactive equilibrium, since both have relatively short half-lives of under 30 minutes. Provided that this assumption is true and that the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from the radionuclides have proportional count rates, no man-made radiation should be present between the two energy levels. This study proved that this assumption was true by demonstrating a linear correlation between the count rates of these two gamma peaks. In conclusion, if the count rates of these two peaks detected in the gamma energy spectrum at a certain time maintain the ratio measured at a normal time, such variation can be confirmed to be caused by natural radiation. Conclusion: This study confirmed that both $^{214}Pb$ and $^{214}Bi$ have relatively short half-lives of under 30 minutes, thereby existing in a radioactive equilibrium in the atmosphere. If the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from these radionuclides have proportional count rates, no man-made radiation should exist between the two energy levels.

Simple and Rapid Evaluation System for Endosulfan Toxicity and Selection of Endosulfan Detoxifying Microorganism Based on Lumbricus rubellus (Lumbricus rubellus를 이용한 endosulfan의 간편, 신속 독성 평가 및 endosulfan 분해 미생물의 선별)

  • Sohn Ho-Yong;Kim Hong-Ju;Kum Eun-Joo;Lee Jung-Bok;Kwon Gi-Seok
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.108-113
    • /
    • 2006
  • To compensate the problems of chemical assay in detoxification of recalcitrant and a practical approach in selection of bioremediation bacteria, a simple and rapid toxicity evaluation system was constructed based on Lumbricus rubellus. Long term-culture and specific equipment are not necessary, and semi-quantitative analysis of toxicity at sub-lethal concentration is possible by measuring of dose-dependent increased yellowish secreted compounds. When the toxicity of endosulfan, its metabolites and structurally related chemicals were measured for 24 h, the results were coincided with previous reports. Toxicity was found in endosulfan, endosulfan sulfate, aldrin, and dieldrin, respectively. Rapid and economic selection of endosulfan-detoxifying bacteria was possible using our system. Klebsiella pneumoniae KE-1, K. oxytoca KE-8 and Pseudomonas sp. KS-2P, reported endosulfan degrading bacteria, ameliorated the endosulfan toxicity, whereas E. coli, B. subtilis and other bacteria failed to protect the toxicity of endosulfan in L. rubellus. Our results suggest that the constructed system is useful to selection of microorganism as well as toxicity evaluation against toxic recalcitrants.

Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions (400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정)

  • Kim, Sunghwan;Nam, Uk-Won;Lee, Jaejin;Park, Won-Kee;Pyo, Jeonghyun;Moon, Bong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • In this study, equivalent dose and LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) were performed using 400 MeV/u C heavy ions in HIMAC (Heavy Ion Medical Accelerator in Chiba) for high LET radiation therapy. The irradiated CR-39 SSNDTs were etched according the etching condition of JAXA (Japan Aerospace Exploration Agency). And the etched SSNTDs were analyzed by using Image J. Determined frequency mean dose (${\bar{y_D}}$)and dose-mean lineal energy (${\bar{y_F}}$)of 400 MeV/u C are about 8.5keV/mm and 10.1 keV/mm, respectively by using the CR-39 SSNTD. This value is very similar to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC (Tissue Equivalent Proportional Counter) active radiation detector. We could determine the equivalent dose and LET calibration factors of CR-39. And we confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry in hadron radiotherapy.

Study for Enhancement of the Detection Sensitivity in Hand-Held X-Ray Fluorescence Device (휴대용 XRF 장치의 검출감도 향상에 관한 연구)

  • Kim, Sung-Soo;Lee, Youn-Seoung;Kim, Do-Yun;Ko, Dong-Seob
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.409-415
    • /
    • 2011
  • The method to improve the detection sensitivity of Hand-held XRF (X-Ray Fluorescence) device currently being developed is discussed. To minimize the loss of the intensity due to atmospheric gas molecules, the vacuum module, which can be filled with atmospheric or He gas, between the sample and the detector was installed. And the change of the detection sensitivity was measured in a vacuum and in the He gas-filled state. As a result, the following three important results were obtained; Firstly, XRF intensity was increased 2~4 times in the low energy range (3~4 keV). It is a very important result because the enhancement of the detection sensitivity means shortening of the detection time in Hand-held XRF device. Secondly, the possibility of detection of the elements less than 3 keV in emission energy was confirmed. Thirdly, the absorption by atmospheric gas molecules can be minimized without vacuum- sealed vessel in Hand-held XRF device, if the vacuum module filled with He gas is used. We concluded that all of three results are very meaningful in the development of a Hand-held XRF device.

The Study of Fermented Chestnut Meal and Its Rumen Fermentation Characteristics (밤의 부위별 발효사료 제조 및 이들의 반추위 내 발효특성에 관한 연구)

  • Joo, Young-Ho;Kim, Dong-Hyeon;Lee, Hyuk-Jun;Lee, Seong-Shin;Paradhipta, Dimas H.V.;Ha, Chang-Ju;Kim, Sam-Churl
    • Journal of Environmental Science International
    • /
    • v.28 no.6
    • /
    • pp.527-533
    • /
    • 2019
  • The aim of present study was to investigate the effect of three types of Chestnut Meals (CM) on chemical composition and rumen fermentation characteristics of the fermented diet. The inoculants consisted of Lactobacillus acidophilus, Bacillus subtilis, and Sacaromyces cerevisiae and were applied to three different types of CM; Whole Chestnut (WC), endodermis (EN), and kernel (KE). All types of CMs were ensiled at $39^{\circ}C$ for 0, 1, 2, 4, or 6 days. After ensiling, the fermented CMs were sub-sampled for laboratory assays. On day six of fermentation, counts of the lactic acid-producing Bacillus subtilis, and yeast were higher (P<0.05) in WC than in the other CM types. On day four, KE had higher (P<0.05) crude protein content but lower (P<0.05) neutral detergent fiber and acid detergent fiber contents than the other treatments. In terms of rumen digestibility, KE had the highest (P<0.05) in vitro digestibility of dry matter (IVDMD), neutral detergent fiber digestibility (IVNDFD), total volatile fatty acid (VFA), propionate, butyrate concentrations, and total gas volume, as well as the lowest (P<0.05) acetate concentration. On the other hand, EN had the highest (P<0.05) pH and ammonia-N concentration in the rumen. In the rumen, even though WC application produced the highest microbial count and fermentation characteristics, it did not have a beneficial effect on rumen digestibility. Therefore, this study concluded that application of KE could be recommended due to the observed improvements in IVDMD and IVNDFD.

A Study on the Improvement of Gamma Ray Energy Spectrum Resolution through Electrical Noise Reduction of High Purity Ge Detector (고순도 Ge 검출기의 전기적 노이즈 감소를 통한 감마선 에너지 스펙트럼의 분해능 향상에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.849-856
    • /
    • 2020
  • In the gamma-ray energy spectrum study, nuclide analysis through energy analysis is very important. High-purity Ge detectors, which are commonly used for gamma-ray energy measurements, are commonly used because of their high energy resolution and relatively high detection efficiency. However, in order to maintain a high energy resolution, the semiconductor detector has a problem in that it is difficult to maintain the original performance if the noise generated from the surrounding environment is not effectively blocked, and the effect of the expensive device is not achieved. Therefore, in this study, ground loop isolator (NEXT-001HDGL) was used to remove the electrical noise generated from the detector. In order to test the effect of improving energy resolution, HPGe detection device newly installed in the proton accelerator KOMAC was used. In the case of gamma-ray energy 2614 keV, the energy resolution was improved from (0.16 ± 0.02) % to (0.11 ± 0.01) %, and in the case of gamma-ray energy 662 keV of 137Cs isotope, the energy resolution was improved from (0.72 ± 0.07) % to (0.27 ± 0.03) %. This result is considered to be very useful for the gamma ray spectrum study using the HPGe detection equipment of KOMAC(Korea Multi-Purpose Accelerator Complex).

Study of Naturally Occurring Radioactive Material Present in Deep Soil of the Malwa Region of Punjab State of India Using Low Level Background Gamma-Ray Spectrometry

  • Srivastava, Alok;Chahar, Vikash;Chauhan, Neeraj;Krupp, Dominik;Scherer, Ulrich W.
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • Background: Epidemiological observations such as mental retardation, physical deformities, etc., in children besides different types of cancer in the adult population of the Malwa region have been reported. The present study is designed to get insight into the role of naturally occurring radioactive material (NORM) in causing detrimental health effects observed in the general population of this region. Materials and Methods: Deep soil samples were collected from different locations in the Malwa region. Their activity concentrations were determined using low-level background gammaray spectrometry. High efficiency and high purity germanium detector capped in a lead-shielded chamber having a resolution of 1.8 keV at 1,173 keV and 2.0 keV at the 1,332 keV line of 60Co was used in the present work. Data were evaluated with Genie-2000 software. Results and Discussion: Mean activity concentrations of 238U, 232Th, and 40K in deep soil were found to be 101.3 Bq/kg, 65.8 Bq/kg, and 688.6 Bq/kg, respectively. The mean activity concentration of 238U was found to be three and half times higher than the global average prescribed by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). It was further observed that the activity concentration of 232Th and 40K has a magnitude that is nearly one and half times higher than the global average prescribed by UNSCEAR. In addition, the radioisotope 137Cs which is likely to have its origin in radiation fallout was also observed. It is postulated that the NORM present in high quantity in deep soil somehow get mobilized into the water aquifers used by the general population and thereby causing harmful health problems. Conclusion: It can be stated that the present work has been able to demonstrate the use of low background gamma-ray spectrometry to understand the role of NORM in causing health-related effects in a general population of the Malwa region of Punjab, India.

The Distribution Characteristics of Topographical Relieves at Each Geological Area in Gyeongsangbuk-do Province using GIS (GIS를 이용한 경상북도 지질 지역별 지형 기복의 분포 특성)

  • KIM, Dae-Sik;LEE, Gwang-Ryul
    • Journal of The Geomorphological Association of Korea
    • /
    • v.17 no.3
    • /
    • pp.49-57
    • /
    • 2010
  • The topographical rolling distribution characteristics of 10 geological areas in Gyeongsangbuk-do are analyzed using GIS. PEs, PEgrgn, Pp2, Kav·Kiv, and Khgr regions occupy the more than 60% that are a steep slope-a high elevation and a steep slope-a middle elevation region, and form high moutains in Gyeongsangbuk-do. Meanwhile, Ke1-9 and Te1-2 regions take possession of the more than 70% that are a low elevation region. Ke1-9 region form landward flatlands and hills around Nakdong river and tributaries of Nakdong river in Gyeongsangbuk-do. Then, Te1-2 region form coastal lowlands adjacent the East sea in Gyeongsangbuk-do. Also, Jgr region take possession of the more than 70% that are a middle elevation region, and form low moutains or flatlands in Gyeongsangbuk-do. Finally, Ols1 region take possession of the more than 50% that are a steep slope region, and form landward moutains in Gyeongsangbuk-do.

Monte Carlo Simulation of Absorbed Energy by Gold Nano-Particles for Proton (양성자에 대한 금 나노입자의 밀도에 따른 흡수 에너지의 몬테카를로 전산모사)

  • Kwon Su Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Proton therapy is known for its superior treatment method due to Bragg peak. To enhance the therapeutic effects of protons, research has been conducted on distributing gold nanoparticles within tumors to increase the absorbed dose. While previous studies focused on handling gold nanoparticles at micrometer and nonometer scale, this study proposes a method to computationally estimate the effect of gold nanoparticles at the millimeter scale. The Geant4 toolkit was applied to computational modeling. Assuming a uniform distribution of water, similar to the human body, and gold nanoparticles, the concentration of gold nanoparticles was adjusted using density ratios. When the density ratio was 5%, the gain in absorbed energy due to gold nanoparticles was nearly twice that of the pure water phantom at the Bragg peak. As the density ratio increased, the gain in absorbed energy linearly increased. When gold nanoparticles were distributed in only one voxel at the Bragg peak, the energy of the protons affected only the neighboring voxels. However, in cases where gold nanoparticles were distributed over a wide area, the volume showing 95% of the maximum absorbed energy (9.46 keV) for the pure water phantom (9.95 keV) exhibited an improvement in absorbed energy over a region 16 times larger, and this region increased as the density ratio increased. Further research is needed to quantify the relationship between the density ratio of gold nanoparticles and the relative biological effect (RBE) in the millimeter scale.