• Title/Summary/Keyword: KS (Korea Standard)

Search Result 424, Processing Time 0.029 seconds

An Experimental Study on the Physical Property of Non-Vulcanized Waterproofing Synthetic Rubber Sheet for the Underground Concrete Wall (지하 콘크리트 벽체용 미가황 합성고무시트 방수재의 물성에 관한 실험적 연구)

  • Choi, Eun Su;Lee, Dae Woo;Seo, Sang Kyo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.69-78
    • /
    • 2012
  • This paper study on the physical property of naturally vulcanizing waterproofing synthetic rubber sheet for the underground concrete wall. In order to finding the naturally vulcanizing time, the relation of vulcanizing time and tensile strength is analysed from non-vulcanizing to naturally vulcanizing time. Physical tests such as tensile strength, tear strength: etc., under the thermal environment temperature at $-20^{\circ}C$, $-10^{\circ}C$, $20^{\circ}C$, $60^{\circ}C$. The result of experiment show that the developed rubber sheet has the delay time about 85 days and the curing time about 35 days. The tensile strength increased by about 692% and coefficient of expansion decreased by about 10% which value can be sufficiently compensate the demerit of vulcanized rubber sheet. Also, all of the physical properties of the naturally rubber sheet satisfy the KS standard and compare to the vulcanized rubber sheet, the developed naturally rubber sheet have excellent durability.

Experimental Study on the Hygrothermal Ageing Effect to the Strength of CFRP Materials for Marine Leisure Boat (열수노화 조건에서 레저선박용 탄소섬유강화플라스틱의 강도변화에 관한 실험적 연구)

  • Jeong, Han Koo;Noh, Jackyou
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.3
    • /
    • pp.205-214
    • /
    • 2018
  • This paper deals with the experimental study on the hygrothermal ageing effect to the strength of Carbon Fiber Reinforced Plastics (CFRP) materials for marine leisure boat manufactured by vacuum assisted resin infusion method. The experiments performed consist of tensile, flexural and shear tests according to American Society for Testing and Materials (ASTM) and Korean Industrial Standards (KS) test methods. Test coupons are varied from uni-directional(UD, $0^{\circ}$, $90^{\circ}$), Bi-Directional (BD), and Double-Bias (DB) carbon fiber fabrics in conjunction with epoxy resin. The results of tensile test show that tensile strength reduces significantly while not the same degree of reduction is observed for elasticity modulus with respect to the existence of hygrothermal ageing effect. This implies that the tensile strain induced from external load holds steady values but ultimate strength values change widely under hygrothermal ageing effect. In case of the flexural test, $0^{\circ}$ UD shows more strength reduction than $90^{\circ}$ UD while BD has reduced values in both flexural strength and elasticity modulus under hygrothermal ageing effect. It is learned that the bending strain induced from external load and ultimate strength values are reduced with respect to hygrothermal ageing effect. Shear test performed only on DB materials, and the results show marginal reduction in ultimate strength and moderate reduction in elasticity modulus. This means that the shear strain varies more than ultimate shear strength with respect to hygrothermal ageing effect. The experiment conducted in this paper clearly demonstrates the differences in material properties of the CFRP for the consideration of hygrothermal ageing effect. Findings obtained from this experimental study can serve as a fundamental input data for the realistic structural responses of marine leisure boat built in CFRP materials.

Mechanical Properties and Durability of Concrete in Relation to the Amount of Limestone Use (석회석 혼입량에 따른 콘크리트의 역학적 및 내구특성)

  • Oh, Sungwoo;Shin, Dongcheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.138-144
    • /
    • 2017
  • In order to reduce carbon dioxide emission in construction industry, less amount of cement use can be one of the alternatives to manufacture concrete. One of the non-sintered construction materials are limestone, which is the raw material to manufacture ordinary Portland cement(OPC). A large amount of limestone have already been used as binders such as blended cement in Europe and US. Even European countries were already established the standard of blended cement, where the limestone can be used up to 35 percent. In this study, experimental researches were conducted to investigate the effects of limestone replacement on the mechanical properties and durability of concrete with 15%, 25% and 35% of limestone substitution to use limestone in blended cement. 15 percent use of limestone in blended cement developed equivalent or even higher compressive strengths compared to Plain mixture. Porosity of limestone cement with 15 percent substitution was much lower than Plain mixture. Most durability tests such as concrete carbonation, freeze-thaw cycle and drying shrinkage strains were conducted to evaluate long-term performance, and the test results indicated that 15 percent of limestone use did not significantly influence on the concrete durability compared with plain concrete.

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

Fundamentals of Ecotoxicity Evaluation Methods Using Domestic Aquatic Organisms in Korea: (KII) Green Algae (국내 생물종을 이용한 생태독성평가 기반연구: (III) 녹조류)

  • An, Youn-Joo;Nam, Sun-Hwa;Baek, Yong-Wook
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • Green algae are important primary producers in aquatic ecosystem, and they are sensitive test species in bioassay. Green algae are broadly used to assess the adverse effects of various chemicals by measuring the inhibition of metabolism, reproduction and survival. In this study, we extensively gathered domestic and foreign toxicity test methods conducted using green algae, which are distributed in Korean water environment. Selected eight domestic green algae were Chlamydomonas reinhardtii, Desmodesmus subspicatus (=Scenedesmus subspicatus), Scenedesmus abundans, Scenedesmus acutus, Scenedesmus quadricauda, Podohedriella falcata (=Ankistrodesmus falcatus), Pseudokirchneriella subcapitata (=Selenastrum capricornutum), and Chlorella vulgaris. Forty four test methods were collected from the standard test ones, government reports, SCI papers and Korean research papers. P. subcapitata and D. subspicatus are the most common test species recommended by the standard test methods. Initial cell density and dilution water were the main differences among the test methods we collected. We proposed the suitable ecotoxicity test methods based on domestic green algae in Korea. This study could be a fundamental basis to establish the ecotoxicity test methods by green algae distributed in Korea.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

An Experimental Study on the Compressive Strength of High Strength Concrete According to Testing Condition (시험조건과 고강도콘크리트의 압축강도 관계에 관한 실험적 연구)

  • Chin, Young-Gil;Lee, Yong-Su;Kim, Kwang-Seo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.129-134
    • /
    • 2002
  • The strength and durability of concrete are affected by various factors such as the quality of material, mixing ratio, construction, the method of cure, time elapsed. the condition of test and etc., it is very difficult to pre-estimate the strength of concrete with the use of experimental specimen. The domestic standard of specimen cylindrical type and its sizes are both l0cm$\times$20cm and 15cm$\times$30cm, which are prescribed in KS F2405, and the loading speed is prescribed to test with 2~3kgf/$\textrm{cm}^2$ per second. The loading speed should have great effect on the compressive strength, but in reality in the construction site sometimes the loading speed is applied so dubiously that the value of the compressive strength can be unreliable. And the cross sectional area of a specimen should be level and smooth, otherwise it can be broken at a lower stress than the real strength through the eccentric or intensive working of the load. Capping should be carried out in order to measure the strength correctly. And used for capping are various materials such as capping compound, cement glue, plaster, mechanical grinding and etc. In this study, therefore, I have carried out an experiment on the relationship among the loading speed, the ratio of height to diameter of specimen, the method of capping, and the compressive strength, for the efficient quality control of concrete structures. So this study has been purposed to provide some basic data that can be used effectively at construction sites.

Dyeabilities with Various Fabrics and Chemical Composition of Brown Colorants from Pine Bark (적송수피 색소 성분의 화학적 조성과 섬유 염색성)

  • Kim, Yong-Sook;Bae, Soon Ei
    • Fashion & Textile Research Journal
    • /
    • v.15 no.1
    • /
    • pp.138-146
    • /
    • 2013
  • Chemical compositions and biological functions of brown colorants extracted from pine bark(Pinus densiflora) have been studied. Dyeing test using multifiber fabrics with extracted colorants were preliminary carried out. Dyeing conditions and fastness tests of selected fabrics have been also studied. The brown colorants were produced 1.5% concentrations by solvent extraction from milled pine bark using methanol. The colorants were extracted with 80% methanol as best choice by a criteria of solid quantity and dyeability on fabrics. The chemical compositions were identified as mixtures of taxifolin epicatechin and procyanidin by LC/MS analysis. The brown colorants could be dyed not only natural fibers such as cotton, silk and wool but also synthetic fiber as nylon and semi-synthetic fiber as viscose rayon. Maximum K/S values was shown at 400 nm according to different fiber with color appearance of redish brown. Optimum pH and temperature of dyeing conditions was 4 and above $80^{\circ}C$, respectively. The brown colorants had a strong antioxidant activity compared to Butylated hydroxyanisole as standard and weak antimicrobial activity against E. coli. compared to kanamycin. Washing, rubbing, perspiration, dry cleaning and light fastness for cotton, nylon and silk dyed with the brown colorants were carried out by KS K method. Most of color fastness such as washing, rubbing, perspiration, and dry cleaning were represented as 4-5 grade. However, light fastness was reported as 2-3 grade. From this studies, brown colorants produced pine bark have a high potentials for natural dyeing on fabrics with antioxidant activity.

Solidification/Stabilization of Dyeing Sludge Treated by Fenton Reagent Using Blast Furnace Slag and Fly Ash

  • Lee, Sookoo;Kim, Sebum
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.453-458
    • /
    • 2001
  • This study was performed to reuse the dyeing wastewater sludge treated by Fenton process through the solidification/stabilization technique. To solidify the dyeing sludge the industrial by-products such as blast furnace slag, fly ash and waste sand with cement were used. The laboratory scale and pilot scale test were conducted at room temperature to make construction brick which has high compressive strength and low leaching of heavy metals. The experimental results showed that blast furnace slag and fly ash could be used instead of cement and the products satisfied the regulation of Korean Standards. The blast furnace slag increased the compressive strength and the optimum ratio of slag/dyeing sludge on dry basis was found 0.4. The solidifying agent of SB series could increase rapidly the compressive strength and the optimum ratio of solidifying agent/sludge on dry basis was 0.26 at which the strength was two times compared with non-added condition. The portion of waste and industrial by-products in matrix was over 80%. From the pilot test the optimum pressure in molding was 100kg/$\textrm{cm}^2$ at which the compressive strength was over 100kg/$\textrm{cm}^2$. And the strength increased continuously to 160kg/$\textrm{cm}^2$ until 120 days curing time due to pozzolanic reaction. When SB-20 as a solidifying agent was used, the unconfined compressive strength of dyeing sludge could be obtained 110kg/$\textrm{cm}^2$ which satisfied the regulation of cement brick in Korea Standard(KS).

  • PDF

Development of Sizing System for Medical Compression Stocking of Korean Men (한국 성인 남성의 의료용 압박스타킹 치수 규격 개발)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Fashion & Textile Research Journal
    • /
    • v.19 no.1
    • /
    • pp.61-69
    • /
    • 2017
  • The purpose of this study is to suggest the sizing system of medical compression stockings for Korean adult men in order to develop compression stockings with excellent dimensional fit reflecting the real human body data. Analyses were conducted on the raw data that the subjects consist of 19~60 aged men of Size Korea 2010 in this study. The stature and weight for the pantyhose stockings, and the ankle circumference and calf circumference for the thighs, knees, and calf support types of stockings were selected as the basic dimension items. The size interval of the pantyhose stockings were 2cm in stature and 2kg in weight. In addition, the thigh, knee, and calf support types of stockings were set with ankle circumference and calf circumference set at 1cm intervals. The designation is the same as KS pantyhose standard, S, M, L, XL. As a result, in the case of pantyhose compression stockings for men, the coverage ratio showed 97.2% in total, with 46.3% for M, 36.5% for L, 7.4% for S, and 6.9% for XL. In the case of thigh type, knee type and calf support types, the percentage of coverage was 99.96% in total, with 57.6% in M, 31.1% in L, 4.7% in S, and 1.6% in XL. The results of this study would help to improve the dimensional conformity of the medical compression stockings for Korean adult men.