• Title/Summary/Keyword: KS (Korea Standard)

Search Result 424, Processing Time 0.031 seconds

A Study on The Color Reproduction Properties of Domestic Newspaper Prints (국내 신문 인쇄의 색재현 특성에 대한 평가)

  • Park, Han-Areum;Kang, Sang-Hoon
    • Proceedings of the Korean Printing Society Conference
    • /
    • 2007.11a
    • /
    • pp.29-43
    • /
    • 2007
  • Web offset newspaper prints is the most widely used printing process in domestic printing industry, but there are no industry-wide specifications for press control to assure consistent quality across newspaper printing plants. As newspaper printing becomes more of a commodity and less of an art, it is necessary to develop the print quality specification standard suitable for Korea web offset newspaper printing field. There are a few commonly employed printing standards such as, SNAP(Specification for Non-Heatset Publication) of the US, IFRA(INCA-FIEJ Research Association), J-color (Japan printing machinery association). And there exists KS for domestic standards, however, since it has been directly imported from ISO standards, there are discrepancies in printing materials and media. This paper aims to examine the color reproduction quality of domestic web offset newspaper prints by comparing with foreign standards. Printing experiments on this study have been performed at one of the domestic newspaper printing companies. The color reproduction properties of the web offset newspaper prints are measured by means of densitometry and colorimetry. These measures are evaluated comapratively with the international standards by means of analyzing, the major factors that determine the color reproduction quality of web offset newspapar prints.

  • PDF

A Study on The Color Reproduction Properties of Domestic Newspaper Prints (국내 신문 인쇄의 색재현 특성에 관한 연구)

  • Park, Han-A-Reum;Kang, Sang-Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.25 no.1
    • /
    • pp.27-41
    • /
    • 2007
  • Web offset newspaper prints is the most widely used printing process in domestic printing industry, but there are no industry-wide specifications for press control to assure consistent quality across newspaper printing plants. As newspaper printing becomes more of a commodity and less of an art, it is necessary to develop the print quality specification standard suitable for Korea web offset newspaper printing field. There are a few commonly employed printing standards such as, SNAP (Specification for Non-Heatset Publication) of the US, IFRA(INCA-FIEJ Research Association), J-color (Japan printing machinery association). And there exists KS for domestic standards, however, since it has been directly imported from ISO standards, there are discrepancies in printing materials and media. This paper aims to examine the color reproduction quality of domestic web offset newspaper prints by comparing with foreign standards. Printing experiments on this study have been performed at one of the domestic newspaper printing companies. The color reproduction properties of the web offset newspaper prints are measured by means of densitometry and colorimetry. These measures are evaluated comapratively with the international standards by means of analyzing, the major factors that determine the color reproduction quality of web offset newspaper prints.

  • PDF

A Study on the Combustion Characteristics of Useful Imported Wood for Building Materials - Focusing on the North American species (Douglas-fir, Western Red cedar) and African species(Makore, Padauk, Bubinga) - (국내 유용 건축자재용 수입 목재의 연소특성에 관한 연구 - 북미 산재(Douglas-fir, Western Red cedar)와 아프리카 산재 (Makore, Padauk, Bubinga)를 중심으로 -)

  • Seo, Hyun Jeong;Baek, Jong Kyo;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.8-14
    • /
    • 2017
  • This study examined the combustion and thermal characteristics of imported woods for building materials in Korea. Wooden specimens were confirmed by a cone calorimeter according to the KS F ISO 5660-1 standard. The combustion properties of the wooden specimens were measured in terms of the heat release rate (HRR), total heat released (THR), mass lose rate (MLR), and ignition time (time to ignition; TTI). The optical microscope was used for determine the anatomical characteristics of wood pit and structure. Also, the thermal properties were measured by thermogravimetric analysis (TGA) to determine the thermal stability of wooden specimens. The result of this experiment would be useful for fundamentals of guiding the combustion properties and thermal stability using wood application.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

An study on the Noise rating of water supply and drain installations in apartment bathroom (급배수 설비소음 평가방법 선정을 위한 실험적 연구)

  • Lee, Tai-Kang;Ko, Kwang-Pil;Choi, Eun-Seok;Kim, Hang;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. The measurement procedure of water installations noise in apartment bathroom were established, so it is necessary to provide the evaluating method and criteria to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. After measuring the noise emission from the installations in many apartment bathroom, The noise were evaluated dB(A), N, NC index, To induce the appropriate method, the coefficient of the correlation among the evaluated numbers were analyzed. As a result, the dB(A) method is most easy to evaluating and very high correlated with N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties (종이 물성에 따른 판형 전열교환기의 성능)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

Effect of Paper Properties on the Performance of a Enthalpy Exchanger (종이 물성이 전열교환 엘리먼트 성능에 미치는 영향)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

Hydraulic Reaction Analysis of C3A in Ordinary Portland Cement with Mineral Additions by Rietveld Method (리트벨트법에 의한 혼합재 첨가 보통 포틀랜드 시멘트 중 C3A 수화반응 해석)

  • Lim, Young-Jin;Lee, Seung-Heun;Cho, Jae-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.2
    • /
    • pp.82-87
    • /
    • 2014
  • Due to the revised Korean standard KS L 5201 for Ordinary Portland Cement (OPC), the use of mixed cement has grown from 5% to 10%. This study investigates the hydration behavior of $C_3A$, asit is a cement mixture that is more commonly used than granulated blast furnace slag or limestone alone. Paste samples were prepared with either granulated blast furnace slag or limestone alone. Each sample was compared with the widely used Rietveld method with a cement mixture containing blast furnace slag or limestone. The hydration behavior of $C_3A$ in each OPC sample was assessed and results were analyzed. Granulated blast furnace slag promotes a high initial level of ettringite, but as the days passed, it promotes an increase in monosulfate, leading to cracks and expansion due to the penetration of sulfates in the solution. However, when limestone is added to the mixture, a transformation of ettringite to monosulfate occurs in the presence of the $CaCO_3$ in the limestone. It is considered that this produces hemi-carbonate and mono-carbonate and thus maintains the ettringite level.

Analysis of concrete characteristic depending on chemical admixtures changing component content ratio (화학혼화제의 성분함유율 변화에 따른 콘크리트의 특성분석)

  • Ryu, Hyun-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • W/C and unit volume, which significantly affect quality of concrete related to strength and durability, are regulated at below $185kg/m^3$ for regular concrete generally used in standard specification for constructions. The aim of this research is to develop chemical admixture and find out its potential use by identifying characteristics of admixtures added to soft concrete and hardening concrete, of which content ratio of component for each type of admixtures is subject to change in accordance with unit volume within KS' allowable range. Sodium gluconate, polyoxyethylene nonylphenyl ether, poly carboxylic copolymer in slump, which is characteristic of soft concrete, are deemed highly sensitive while there is no air entrainment except for $10\sim70%$ in WE, WR component content ratio and NP. In hardening concrete, strength in general showed higher action in compressive strength and tensile strength than in plain strength. Use of proper AE agent and AE water reducing agent at the same time is deemed to be used as chemical admixtures capable of manufacturing high-quality, high-quantity concrete.